View larger
Images are for illustrative purposes only. Please refer to data sheet for details
2170856 UNITRONIC BUS PB TRAY 1x2x0,64 LAPP UNITRONIC BUS PB TRAY 1x2x0,64
2170856
2170856
UNITRONIC BUS PB TRAY 1x2x0,64
LAPP
1 m.
UNITRONIC BUS PB TRAY 1x2x0,64
UNITRONIC® BUS PB TRAY
Cables > Data and communication cable
UNITRONIC BUS cabling
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteMore info
▲PROFIBUS DP cable with PLTC-ER approval acc. to UL, for open wiring on cable tray. Temperature range from -40°C bis +80°C
PLTC-ER (power limited tray cable - epxosed run)
Benefits
- Cables can be used for PROFIBUS-DP as well as PROFIBUS-FMS and FIP
- PLTC-ER approval for open wiring between cable tray and industrial machines/plants acc. to NEC 725.154 (D)
- No additional protection of the cable needed
Application range
- For fixed installation or applications with occasional movements
- PROFIBUS DP (in accordance with DIN 19245 and EN 50170, e.g. for SIEMENS SIMATIC® NET, also suitable for FIP - Factory Instrumentation Protocol).
Product features
- Based on the bit rates listed, in accordance with PNO specifications the following maximum cable lengths for a bus segment apply
(cable type A, PROFIBUS-DP):
93.75 kbit/s = 1200 m
187.5 kbit/s = 1000 m
500 kbit/s = 400 m
1.5 Mbit/s = 200 m
12.0 Mbit/s = 100 m - UV-resistant UL SUN RES
- Flame retardant acc. UL 1685 - FT4 (vertical tray)
Norm references / Approvals
- c(UL)us Typ CMG (75°C) acc.to UL 444 / CSA 22.2
- UL Type PLTC-ER acc. to UL 13
Product Make-up
- Bare copper wire, 0,64 mm diameter
- Core colours: red, green
- Overall screening with copper braid and plastic-laminated aluminium foil
- PVC inner sheath and outer sheath
- Colour: violet (RAL 4001)
Classification ETIM 5
- ETIM 5.0 Class-ID: EC000830
- ETIM 5.0 Class-Description: Data cable
Classification ETIM 6
- ETIM 6.0 Class-ID: EC000830
- ETIM 6.0 Class-Description: Data cable
Mutual capacitance
- (1 kHz): max. 30 nF/km
Peak operating voltage
- (not for power applications) 250 V
Impedance
- 150 +/- 15 Ohm
Conductor resistance
- (loop): max. 110 ohm/km
Minimum bending radius
- Fixed installation: 8 x outer diameter
Test voltage
- Core/core: 2000 V
Characteristic impedance
- 150 ± 15 Ohm
Temperature range
- Flexing: -10°C to +70°C
- Fixed installation: -40°C to +80°C