View larger
2170831 UNITRONIC BUS ASI FD (TPE) A 2X1,5 BK LAPP UNITRONIC BUS ASI FD (TPE) A 2X1,5 BK
2170831
2170831
UNITRONIC BUS ASI FD (TPE) A 2X1,5 BK
LAPP
1 m.
Cables > Data and communication cable
UNITRONIC BUS cabling
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Lapp 2170831 UNITRONIC BUS ASI FD (TPE) A 2X1,5 BK LAPP UNITRONIC BUS ASI FD (TPE) A 2X1,5 BK is a flexible fieldbus cable designed for AS-Interface networks operating in high-flex industrial environments. This rugged bus cable facilitates rapid communication between sensors and control units across automated assembly lines. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- TPE variant: UL AWM Style 2103 CSA AWM II A/B: undefined
- core insulation: halogen-free compound: undefined
- Outer sheath: TPE PUR: undefined
- Outer sheath: yellow (RAL 1023), black (RAL 9005): undefined
- 1.5 mm²: max. 13.7 Ohm/km: undefined
- 2.5 mm²: max. 8.21 Ohm/km: undefined
- Fixed installation: 12 mm: undefined
- Flexing without fixing: 24 mm Flexing with fixing: 60 mm (15 x D): undefined
- Core/core: 2000 V: undefined
- Fixed installation: -40°C to +80°C (TPE +105°C): undefined
- Flexing – without fixing: -30 °C to +70 °C (TPE +105 °C): undefined
- ETIM 5.0 Class-ID: EC000830: undefined
- ETIM 5.0 Class-Description: Data cable: undefined
More info
▲Communication at sensor/actuator level. Halogen free (PUR), UL-approval, oil resistant (TPE). Temperature range from -40°C bis +105°C (TPE)
- "FD" = suitable for power chains
- "LD” = Long Distance
Benefits
- The new BUS ASI LD 2 x 2.5 (Long Distance) allows even modules located further away to be connected.
AS-I power supplies can be reduced. The BUS ASI LD is downwards-compatible with version 1.5. - For highly flexible applications (power chains, moving machine parts)
- High oil-resistance
Application range
- Communication at sensor/actuator level
- Sensor-/actuator wiring
Product features
- PUR versions are halogen-free according to IEC 60754-1
- Flame-retardant according to IEC 60332-1-2, UL FT-2 flame test
- Data and power are transmitted via an unscreened, geometrically coded two-core flat cable (protection against polarity reversal).
- The conductor is contacted by "piercing technology" within the ASI modules.
- The sensors are connected to the ASI modules (coupling modules) using round cables (connection cables).
Norm references / Approvals
- ASI is standardised Europe-wide in EN 50295 and internationally in IEC 62026-2.
- TPE variant: UL AWM Style 2103
CSA AWM II A/B
Product Make-up
- Extra-fine wire, tinned copper strands
- core insulation: halogen-free compound
- Outer sheath:
TPE
PUR - Outer sheath: yellow (RAL 1023), black (RAL 9005)
Classification ETIM 5
- ETIM 5.0 Class-ID: EC000830
- ETIM 5.0 Class-Description: Data cable
Classification ETIM 6
- ETIM 6.0 Class-ID: EC000830
- ETIM 6.0 Class-Description: Data cable
Peak operating voltage
- 300 V (not for power applications)
Conductor resistance
- 1.5 mm²: max. 13.7 Ohm/km
- 2.5 mm²: max. 8.21 Ohm/km
Minimum bending radius
- Fixed installation: 12 mm
- Flexing without fixing: 24 mm
Flexing with fixing: 60 mm (15 x D)
Test voltage
- Core/core: 2000 V
Temperature range
- Fixed installation:
-40°C to +80°C (TPE +105°C) - Flexing – without fixing:
-30 °C to +70 °C (TPE +105 °C)