LAPP 2170830 2170830 UNITRONIC BUS ASI FD (TPE) A 2X1,5 YE LAPP UNITRONIC BUS ASI FD (TPE) A 2X1,5 YE View larger
Images are for illustrative purposes only. Please refer to data sheet for details

2170830 UNITRONIC BUS ASI FD (TPE) A 2X1,5 YE LAPP UNITRONIC BUS ASI FD (TPE) A 2X1,5 YE

2170830

2170830

UNITRONIC BUS ASI FD (TPE) A 2X1,5 YE

LAPP

1 m.

UNITRONIC BUS ASI FD (TPE) A 2X1,5 YE UNITRONIC® BUS ASI FD

Cables > Data and communication cable
UNITRONIC BUS cabling

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Communication at sensor/actuator level. Halogen free (PUR), UL-approval, oil resistant (TPE). Temperature range from -40°C bis +105°C (TPE)

  • "FD" = suitable for power chains
  • "LD” = Long Distance

Benefits

  • The new BUS ASI LD 2 x 2.5 (Long Distance) allows even modules located further away to be connected.
    AS-I power supplies can be reduced. The BUS ASI LD is downwards-compatible with version 1.5.
  • For highly flexible applications (power chains, moving machine parts)
  • High oil-resistance

Application range

  • Communication at sensor/actuator level
  • Sensor-/actuator wiring

Product features

  • PUR versions are halogen-free according to IEC 60754-1
  • Flame-retardant according to IEC 60332-1-2, UL FT-2 flame test
  • Data and power are transmitted via an unscreened, geometrically coded two-core flat cable (protection against polarity reversal).
  • The conductor is contacted by "piercing technology" within the ASI modules.
  • The sensors are connected to the ASI modules (coupling modules) using round cables (connection cables).

Norm references / Approvals

  • ASI is standardised Europe-wide in EN 50295 and internationally in IEC 62026-2.
  • TPE variant: UL AWM Style 2103
    CSA AWM II A/B

Product Make-up

  • Extra-fine wire, tinned copper strands
  • core insulation: halogen-free compound
  • Outer sheath:
    TPE
    PUR
  • Outer sheath: yellow (RAL 1023), black (RAL 9005)

Classification ETIM 5

  • ETIM 5.0 Class-ID: EC000830
  • ETIM 5.0 Class-Description: Data cable

Classification ETIM 6

  • ETIM 6.0 Class-ID: EC000830
  • ETIM 6.0 Class-Description: Data cable

Peak operating voltage

  • 300 V (not for power applications)

Conductor resistance

  • 1.5 mm²: max. 13.7 Ohm/km
  • 2.5 mm²: max. 8.21 Ohm/km

Minimum bending radius

  • Fixed installation: 12 mm
  • Flexing without fixing: 24 mm
    Flexing with fixing: 60 mm (15 x D)

Test voltage

  • Core/core: 2000 V

Temperature range

  • Fixed installation:
    -40°C to +80°C (TPE +105°C)
  • Flexing – without fixing:
    -30 °C to +70 °C (TPE +105 °C)

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.