View larger
Images are for illustrative purposes only. Please refer to data sheet for details
2170814 UNITRONIC BUS LD FD P A 2X2X0,25 LAPP UNITRONIC BUS LD FD P A 2X2X0,25
2170814
2170814
UNITRONIC BUS LD FD P A 2X2X0,25
LAPP
1 m.
UNITRONIC BUS LD FD P A 2X2X0,25
UNITRONIC® BUS LD FD P
Cables > Data and communication cable
UNITRONIC BUS cabling
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteMore info
▲For bus systems like e.g. Modbus, SUCOnet, Modulink, VariNet. Flame retardant, UL- approval, Core indet. code DIN 47100. Temperature range from -40°C bis +80°C
LD is a LAPP abbreviation for long distance
Benefits
- Suitable for multiple Bus systems based on RS485 / RS422
- PUR outer sheath, tear and notch-resistant, resistant to mineral oils and abrasion when used in power chains
- Under consideration of the temperature range also suitable for outdoor use
Application range
- For highly flexible applications (power chains, moving machine parts)
- Bus cables for bus systems such as e.g. Modbus, SUCOnet P, Modulink P, VariNet-P)
Product features
- The stated bit rates result in the following cable lengths (maximum) of one bus segment:
- 9.6-93.75 kbit/s = 1200m
- 187.5 kbit/s = max. 1,000 m
- 500 kbit/s = max. 400 m
- UV-resistant (but colour may change after some time)
Norm references / Approvals
- UNITRONIC® BUS LD FD P A:
UL versions with certification:
UL/CSA type CMX acc. to UL 444
and CSA C22.2 no. 214-02 - Flame-retardant according IEC 60332-1-2
Product Make-up
- Extra-fine wire strand made of bare copper
- Colour code DIN 47100
- Core insulation: PE
- Overall screening of braided tinned-copper strands
- Outer sheath: PUR, violet (RAL 4001)
Classification ETIM 5
- ETIM 5.0 Class-ID: EC000830
- ETIM 5.0 Class-Description: Data cable
Classification ETIM 6
- ETIM 6.0 Class-ID: EC000830
- ETIM 6.0 Class-Description: Data cable
Mutual capacitance
- (800 Hz) max. 60 nF/km
Peak operating voltage
- (not for power applications) 250 V
Conductor resistance
- (loop): max. 159.8 ohm/km
Minimum bending radius
- Fixed installation: 6 x core diameter
One bend at end of core:
3 x cable diameter - Flexing: 15 x outer diameter
Test voltage
- Core/core: 1500 V rms
Characteristic impedance
- 100 - 120 Ohm
Temperature range
- Fixed installation: -40°C to +80°C
- Flexing: -30°C to +70°C