View larger
2170371 UNITRONIC BUS ASI LD (G) YE 2x2.5 LAPP UNITRONIC BUS ASI LD (G) YE 2x2.5
2170371
2170371
UNITRONIC BUS ASI LD (G) YE 2x2.5
LAPP
1 m.
Cables > Data and communication cable
UNITRONIC BUS cabling
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Lapp 2170371 UNITRONIC BUS ASI LD (G) YE 2x2.5 LAPP UNITRONIC BUS ASI LD (G) YE 2x2.5 is a dedicated fieldbus communication cable designed to connect actuators and sensors within Actuator Sensor Interface networks. Automation systems rely on these specialized bus cables to streamline decentralized machine topologies and ensure rapid command distribution. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- UL/CSA version: CMG c(UL)us or (UL)CL2 or AWM 300V FT4 certified: undefined
- Conductor: fine-wire tinned-copper strands: undefined
- Core insulation: blue and brown: undefined
- Outer sheath: rubber (G), halogenfree thermoplastic elastomers (TPE) PVC: undefined
- Outer sheath: yellow (RAL 1023), black (RAL 9005), red (RAL 3000): undefined
- Yellow: 300 V (not for power applications) Black: 300 V (not for power applications) Red: 300 V: undefined
- 1.5 mm²: max. 13.7 Ohm/km: undefined
- 2.5 mm²: max. 8.21 Ohm/km: undefined
- Fixed installation: 12 mm: undefined
- Core/core: 2000 V: undefined
- Dependent on outer sheath material: PVC: -30°C to +90°C Other materials: -40°C to +85°C: undefined
- During installation: PVC -20 °C to +90 °C Other materials: -30 °C to +85 °C: undefined
- ETIM 5.0 Class-ID: EC000830: undefined
- ETIM 5.0 Class-Description: Data cable: undefined
More info
▲Communication at sensor/actuator level. Halogen free (rubber), UL-approval (PVC), oil resistant (TPE). Temperature range from -40°C bis +90°C
"LD” = Long Distance
Benefits
- The new BUS ASI LD 2 x 2.5 (Long Distance) allows even modules located further away to be connected.
AS-I power supplies can be reduced. The BUS ASI LD is downwards-compatible with version 1.5. - The rubber versions are halogen-free
Application range
- Communication at sensor/actuator level
- Sensor-/actuator wiring
- For fixed installation as well as occasional flexing at free, non-continuously recurring movement without tensile load
- The TPE version has an oil-resistant outer sheath. It is suitable for wet areas, in particular in conjunction with water-soluble cooling lubricants.
Product features
- Data and power are transmitted via an unscreened, geometrically coded two-core flat cable (protection against polarity reversal).
- The conductor is contacted by "piercing technology" within the ASI modules.
- The sensors are connected to the ASI modules (coupling modules) using round cables (connection cables).
Norm references / Approvals
- ASI is standardised Europe-wide in EN 50295 and internationally in IEC 62026-2.
- PVC A version with UL/CSA (CMX) certification
- UL/CSA version: CMG c(UL)us or (UL)CL2 or AWM 300V FT4 certified
Product Make-up
- Conductor: fine-wire tinned-copper strands
- Core insulation: blue and brown
- Outer sheath:
rubber (G), halogenfree
thermoplastic elastomers (TPE)
PVC - Outer sheath: yellow (RAL 1023), black (RAL 9005), red (RAL 3000)
Classification ETIM 5
- ETIM 5.0 Class-ID: EC000830
- ETIM 5.0 Class-Description: Data cable
Classification ETIM 6
- ETIM 6.0 Class-ID: EC000830
- ETIM 6.0 Class-Description: Data cable
Peak operating voltage
- Yellow: 300 V (not for power applications)
Black: 300 V (not for power applications)
Red: 300 V
Conductor resistance
- 1.5 mm²: max. 13.7 Ohm/km
- 2.5 mm²: max. 8.21 Ohm/km
Minimum bending radius
- Fixed installation: 12 mm
- Flexible use 24 mm
Test voltage
- Core/core: 2000 V
Temperature range
- Dependent on outer sheath material:
PVC: -30°C to +90°C
Other materials: -40°C to +85°C - During installation:
PVC -20 °C to +90 °C
Other materials:
-30 °C to +85 °C