LAPP 2170370 2170370 UNITRONIC BUS CC FD P FRNC 3x1xAWG20 LAPP UNITRONIC BUS CC FD P FRNC 3x1xAWG20 View larger
Images are for illustrative purposes only. Please refer to data sheet for details

2170370 UNITRONIC BUS CC FD P FRNC 3x1xAWG20 LAPP UNITRONIC BUS CC FD P FRNC 3x1xAWG20

2170370

2170370

UNITRONIC BUS CC FD P FRNC 3x1xAWG20

LAPP

1 m.

UNITRONIC BUS CC FD P FRNC 3x1xAWG20 UNITRONIC® BUS CC FD P FRNC

Cables > Data and communication cable
UNITRONIC BUS cabling

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

CC-Link to provide efficient, integrated factory and process automation. UV-resistant, flame retardant. AWM style 300V. Temperature range from -40°C bis +80°C

Lapp Kabel is a regular member of the user organisation CC-Link Partner Association (CLPA), Japan.

Benefits

  • The CC-Link® system was developed by Mitsubishi Electric Automation, Japan.

Application range

  • CC-Link® (Control & Communication Link) = field bus network, for both control as well as information data to provide efficient, integrated factory and process automation.
  • For highly flexible applications (power chains, moving machine parts)

Product features

  • Transmission rate in relation to the distance
  • 156 kbit/s 1.200 m
    625 kbit/s 600 m
    2,5 Mbit/s 200 m
    5,0 Mbit/s 110-150 m
    10 Mbit/s 50-100 m
  • Halogen-free
  • Flame-retardant according IEC 60332-1-2

Norm references / Approvals

  • AWM 20233 80 °C 300V

Product Make-up

  • Bare stranded copper wires
  • Core insulation: PE
  • Inner sheath: FRNC
  • Overall screening of braided tinned-copper strands
  • Outer sheath: PUR, red (RAL 3000)

Classification ETIM 5

  • ETIM 5.0 Class-ID: EC000830
  • ETIM 5.0 Class-Description: Data cable

Classification ETIM 6

  • ETIM 6.0 Class-ID: EC000830
  • ETIM 6.0 Class-Description: Data cable

Certifications

  • UL AWM Style 20233

Peak operating voltage

  • 300 V

Conductor resistance

  • 11 ohm/1,000 ft. (305 m) at 20°C

Minimum bending radius

  • Fixed installation: 4 x outer diameter
  • Moved: 10 x outer diameter

Test voltage

  • 2000 V

Characteristic impedance

  • 110 ohm at 1 MHz

Temperature range

  • -40°C to +80°C

Product Datasheet