LAPP 2170357 2170357 UNITRONIC BUS ASI FD P FRNC YE LAPP UNITRONIC BUS ASI FD P FRNC YE View larger
Images are for illustrative purposes only. Please refer to data sheet for details

2170357 UNITRONIC BUS ASI FD P FRNC YE LAPP UNITRONIC BUS ASI FD P FRNC YE

2170357

2170357

UNITRONIC BUS ASI FD P FRNC YE

LAPP

1 m.

UNITRONIC BUS ASI FD P FRNC YE UNITRONIC® BUS ASI FD

Cables > Data and communication cable
UNITRONIC BUS cabling

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Designed as a Lapp 2170357 UNITRONIC BUS ASI FD P FRNC YE data cable, this flexible yellow network line is engineered for continuous movement in Actuator-Sensor Interface loops. Drag-chain compatible bus cables ensure uninterrupted communication between decentralized field devices and master control units in dynamic machine operations.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • TPE variant: UL AWM Style 2103 CSA AWM II A/B
  • core insulation: halogen-free compound
  • Outer sheath: TPE PUR
  • Outer sheath: yellow (RAL 1023), black (RAL 9005)
  • 1.5 mm²: max. 13.7 Ohm/km
  • 2.5 mm²: max. 8.21 Ohm/km
  • Fixed installation: 12 mm
  • Flexing without fixing: 24 mm Flexing with fixing: 60 mm (15 x D)
  • Core/core: 2000 V
  • Fixed installation: -40°C to +80°C (TPE +105°C)
  • Flexing – without fixing: -30 °C to +70 °C (TPE +105 °C)
  • ETIM 5.0 Class-ID: EC000830
  • ETIM 5.0 Class-Description: Data cable
  • ETIM 6.0 Class-ID: EC000830
  • ETIM 6.0 Class-Description: Data cable

More info

▲

Communication at sensor/actuator level. Halogen free (PUR), UL-approval, oil resistant (TPE). Temperature range from -40°C bis +105°C (TPE)

  • "FD" = suitable for power chains
  • "LD” = Long Distance

Benefits

  • The new BUS ASI LD 2 x 2.5 (Long Distance) allows even modules located further away to be connected.
    AS-I power supplies can be reduced. The BUS ASI LD is downwards-compatible with version 1.5.
  • For highly flexible applications (power chains, moving machine parts)
  • High oil-resistance

Application range

  • Communication at sensor/actuator level
  • Sensor-/actuator wiring

Product features

  • PUR versions are halogen-free according to IEC 60754-1
  • Flame-retardant according to IEC 60332-1-2, UL FT-2 flame test
  • Data and power are transmitted via an unscreened, geometrically coded two-core flat cable (protection against polarity reversal).
  • The conductor is contacted by "piercing technology" within the ASI modules.
  • The sensors are connected to the ASI modules (coupling modules) using round cables (connection cables).

Norm references / Approvals

  • ASI is standardised Europe-wide in EN 50295 and internationally in IEC 62026-2.
  • TPE variant: UL AWM Style 2103
    CSA AWM II A/B

Product Make-up

  • Extra-fine wire, tinned copper strands
  • core insulation: halogen-free compound
  • Outer sheath:
    TPE
    PUR
  • Outer sheath: yellow (RAL 1023), black (RAL 9005)

Classification ETIM 5

  • ETIM 5.0 Class-ID: EC000830
  • ETIM 5.0 Class-Description: Data cable

Classification ETIM 6

  • ETIM 6.0 Class-ID: EC000830
  • ETIM 6.0 Class-Description: Data cable

Peak operating voltage

  • 300 V (not for power applications)

Conductor resistance

  • 1.5 mm²: max. 13.7 Ohm/km
  • 2.5 mm²: max. 8.21 Ohm/km

Minimum bending radius

  • Fixed installation: 12 mm
  • Flexing without fixing: 24 mm
    Flexing with fixing: 60 mm (15 x D)

Test voltage

  • Core/core: 2000 V

Temperature range

  • Fixed installation:
    -40°C to +80°C (TPE +105°C)
  • Flexing – without fixing:
    -30 °C to +70 °C (TPE +105 °C)

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.