View larger
2170335 UNITRONIC BUS PA FC (BK) 1X2X1.0 LAPP UNITRONIC BUS PA FC (BK) 1X2X1.0
2170335
2170335
UNITRONIC BUS PA FC (BK) 1X2X1.0
LAPP
1 m.
Cables > Data and communication cable
UNITRONIC BUS cabling
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Manufactured by Lapp under part number 2170335, this UNITRONIC BUS PA FC (BK) 1X2X1.0 data cable is built for process automation fieldbus networks adhering to PROFIBUS PA standards. Fieldbus cables facilitate digital communication between process control systems and field instrumentation in process industries. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Technical Data: refer to the overview on UNITRONIC® Bus Cables
- (loop): max. 44 ohm/km
- Fixed installation: 10 x outer diameter
- Core/core: 1500 V rms
- Fixed installation: -30°C to +80°C
- During installation: -5°C to +50°C
- ETIM 5.0 Class-ID: EC000830
- ETIM 5.0 Class-Description: Data cable
- ETIM 6.0 Class-ID: EC000830
- ETIM 6.0 Class-Description: Data cable
More info
▲Process-automation application connecting sensors and actuators - including areas with risks of explosion. Temperature range from -30°C bis +80°C
- PA = Process Automation
- Variant with UL/CSA CMG
Benefits
- FC (Fast Connect) version is oil and UV-resistant
Application range
- Process-automation application for connecting sensors and actuators - including areas with risks of explosion.
- Fixed Installation
Product features
- Bit rate = 31.25 kbit/s. Transmission technology RS485 also possible but bit rate is limited to 1.5 Mbit/s
- Maximum cable length is dependent on several factors (e.g. supply voltage, current demand).
- Technical Data: refer to the overview on "UNITRONIC® Bus Cables"
- Flame-retardant according IEC 60332-1-2
Norm references / Approvals
- PROFIBUS® PA is standardised in EN 50170 as PROFIBUS® DP and PROFIBUS® FMS
- Transmission technology for PROFIBUS-PA in accordance with international standard IEC 61158-2
- FC variant with
UL/CSA certification (CMG / PLTC)
Product Make-up
- UNITRONIC®BUS PA
Stranded conductor
Copper braiding
Outer sheath: PVC, blue, (RAL 5015) intrinsically safe area, black (RAL 9005) - UNITRONIC® BUS PA FC
Bare copper wire
Fast Connect inner sheath
Cu-Geflecht
Puter sheath: PVC, blue (RAL 5015), black (RAL 9005)
Classification ETIM 5
- ETIM 5.0 Class-ID: EC000830
- ETIM 5.0 Class-Description: Data cable
Classification ETIM 6
- ETIM 6.0 Class-ID: EC000830
- ETIM 6.0 Class-Description: Data cable
Peak operating voltage
- (not for power applications) 250 V
Conductor resistance
- (loop): max. 44 ohm/km
Minimum bending radius
- Fixed installation: 10 x outer diameter
Test voltage
- Core/core: 1500 V rms
Characteristic impedance
- 100 ± 20 Ohm
Temperature range
- Fixed installation: -30°C to +80°C
- During installation: -5°C to +50°C