View larger
2170332 UNITRONIC BUS PB TORSION 1X2X0,8 LAPP UNITRONIC BUS PB TORSION 1X2X0,8
2170332
2170332
UNITRONIC BUS PB TORSION 1X2X0,8
LAPP
1 m.
Cables > Data and communication cable
UNITRONIC BUS cabling
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Configured as a Lapp 2170332 UNITRONIC BUS PB TORSION 1X2X0,8 data cable, this specialized line is engineered to withstand severe torsional stress in robotic arms and articulated industrial machinery running PROFIBUS protocols.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- TORSION: for torsional stress, e.g. robot application
- ± 180° per 1 m:
- Certification: UL type CMX in accordance with UL 444
- Core insulation: PE
- Outer sheath: PUR, violet (RAL 4001)
- (800 Hz): max. 30 nF/km
- Fixed installation: 4 x outer diameter
- Flexing: 7.5 x outer diameter
- Operating temperature: -25°C to 75°C
- Storage temp.: -40°C to 80°C
- ETIM 5.0 Class-ID: EC000830
- ETIM 5.0 Class-Description: Data cable
- ETIM 6.0 Class-ID: EC000830
- ETIM 6.0 Class-Description: Data cable
More info
▲Bus cable for PROFIBUS-DP, -FMS and FIP. For torsional stress, e.g. robot; ± 180° per 1 m, halogen free, flame ratardant. Temp. Range from -25°C bis 75°C
Benefits
- For use where the combination of a halogen-free outer sheath with properties similar to PUR and enhanced flame-retardance is required
- Cables can be used for PROFIBUS-DP as well as PROFIBUS-FMS and FIP
Application range
- PROFIBUS DP (in accordance with DIN 19245 and EN 50170, e.g. for SIEMENS SIMATIC® NET, also suitable for FIP - Factory Instrumentation Protocol).
Product features
- TORSION: for torsional stress, e.g. robot application; ± 180° per 1 m
- Halogen-free
- Flame-retardant according IEC 60332-1-2
- Based on the bit rates listed, in accordance with PNO specifications the following maximum cable lengths for a bus segment apply
(cable type A, PROFIBUS-DP):
93.75 kbit/s = 1200 m
187.5 kbit/s = 1000 m
500 kbit/s = 400 m
1.5 Mbit/s = 200 m
12.0 Mbit/s = 100 m
Norm references / Approvals
- Certification: UL type CMX in accordance with UL 444
Product Make-up
- Stranded bare copper wire
- Core insulation: PE
- Overall screening with copper braid and plastic-laminated aluminium foil
- Outer sheath: PUR, violet (RAL 4001)
Classification ETIM 5
- ETIM 5.0 Class-ID: EC000830
- ETIM 5.0 Class-Description: Data cable
Classification ETIM 6
- ETIM 6.0 Class-ID: EC000830
- ETIM 6.0 Class-Description: Data cable
Mutual capacitance
- (800 Hz): max. 30 nF/km
Peak operating voltage
- (not for power applications)
300 V
Torsion movement in WTG (wind turbine generator)
- Max. torsion load
- ± 180°/m
Minimum bending radius
- Fixed installation: 4 x outer diameter
- Flexing: 7.5 x outer diameter
Test voltage
- 3600 V DC (3 sec.)
Characteristic impedance
- 150 ± 15 Ohm
Temperature range
- Operating temperature: -25°C to 75°C
- Storage temp.: -40°C to 80°C