View larger
2170331 UNITRONIC BUS PB FESTOON 1X2X0,64 LAPP UNITRONIC BUS PB FESTOON 1X2X0,64
2170331
2170331
UNITRONIC BUS PB FESTOON 1X2X0,64
LAPP
1 m.
Cables > Data and communication cable
UNITRONIC BUS cabling
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Lapp 2170331 UNITRONIC BUS PB FESTOON 1X2X0,64 cable is engineered specifically for festoon systems and dynamic cable carrier applications on heavy industrial cranes and machinery. Festoon cables withstand repetitive mechanical stress and travel along overhead tracks in manufacturing and material handling plants. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- FESTOON: for cable trolley (festoon)
- Outer sheath: special PVC compound
- (800 Hz): max. 30 nF/km
- Flexing: 70 mm
- Fixed installation: 30 mm once
- Core/core: 2000 V
- Flexing: -5°C to +70°C
- Fixed installation: -40°C to +80°C
- ETIM 5.0 Class-ID: EC000830
- ETIM 5.0 Class-Description: Data cable
- ETIM 6.0 Class-ID: EC000830
- ETIM 6.0 Class-Description: Data cable
More info
▲Bus cable for PROFIBUS-DP, -FMS and FIP. UL/CSA-approvals (CMG, CL3, SUN RES, Oil Res I), Flame retardant CSA FT4 UL, oil resistant UL OIL RES I
Benefits
- Cables can be used for PROFIBUS-DP as well as PROFIBUS-FMS and FIP
- CL3 for installation on trays
Application range
- PROFIBUS DP (in accordance with DIN 19245 and EN 50170, e.g. for SIEMENS SIMATIC® NET, also suitable for FIP - Factory Instrumentation Protocol).
Product features
- FESTOON: for cable trolley (festoon)
- Based on the bit rates listed, in accordance with PNO specifications the following maximum cable lengths for a bus segment apply
(cable type A, PROFIBUS-DP):
93.75 kbit/s = 1200 m
187.5 kbit/s = 1000 m
500 kbit/s = 400 m
1.5 Mbit/s = 200 m
12.0 Mbit/s = 100 m
Norm references / Approvals
- With UL/CSA certification (CMG, CL3, SUN RES, Oil Res I)
- Flame-retardant according to CSA FT4
UL Vertical-Tray Flame Test - Oil-resistant according to UL OIL RES I
Product Make-up
- Outer sheath: special PVC compound
Classification ETIM 5
- ETIM 5.0 Class-ID: EC000830
- ETIM 5.0 Class-Description: Data cable
Classification ETIM 6
- ETIM 6.0 Class-ID: EC000830
- ETIM 6.0 Class-Description: Data cable
Mutual capacitance
- (800 Hz): max. 30 nF/km
Peak operating voltage
- 600 V (not for power applications)
Minimum bending radius
- Flexing: 70 mm
- Fixed installation: 30 mm once
Test voltage
- Core/core: 2000 V
Characteristic impedance
- 150 ± 15 Ohm
Temperature range
- Flexing: -5°C to +70°C
- Fixed installation: -40°C to +80°C