Request QuoteProduct Overview
A Lapp UNITRONIC BUS ASI LD FD P YE 2x2,5 data cable is specifically applied in Actuator Sensor Interface networks to connect distributed field devices to master controllers. Specialized bus cabling ensures reliable power and data distribution across modular machine setups. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- TPE variant: UL AWM Style 2103 CSA AWM II A/B
- core insulation: halogen-free compound
- Outer sheath: TPE PUR
- Outer sheath: yellow (RAL 1023), black (RAL 9005)
- 1.5 mm²: max. 13.7 Ohm/km
- 2.5 mm²: max. 8.21 Ohm/km
- Fixed installation: 12 mm
- Flexing without fixing: 24 mm Flexing with fixing: 60 mm (15 x D)
- Core/core: 2000 V
- Fixed installation: -40°C to +80°C (TPE +105°C)
- Flexing – without fixing: -30 °C to +70 °C (TPE +105 °C)
- ETIM 5.0 Class-ID: EC000830
- ETIM 5.0 Class-Description: Data cable
- ETIM 6.0 Class-ID: EC000830
- ETIM 6.0 Class-Description: Data cable
More info
▲Communication at sensor/actuator level. Halogen free (PUR), UL-approval, oil resistant (TPE). Temperature range from -40°C bis +105°C (TPE)
- "FD" = suitable for power chains
- "LD” = Long Distance
Benefits
- The new BUS ASI LD 2 x 2.5 (Long Distance) allows even modules located further away to be connected.
AS-I power supplies can be reduced. The BUS ASI LD is downwards-compatible with version 1.5. - For highly flexible applications (power chains, moving machine parts)
- High oil-resistance
Application range
- Communication at sensor/actuator level
- Sensor-/actuator wiring
Product features
- PUR versions are halogen-free according to IEC 60754-1
- Flame-retardant according to IEC 60332-1-2, UL FT-2 flame test
- Data and power are transmitted via an unscreened, geometrically coded two-core flat cable (protection against polarity reversal).
- The conductor is contacted by "piercing technology" within the ASI modules.
- The sensors are connected to the ASI modules (coupling modules) using round cables (connection cables).
Norm references / Approvals
- ASI is standardised Europe-wide in EN 50295 and internationally in IEC 62026-2.
- TPE variant: UL AWM Style 2103
CSA AWM II A/B
Product Make-up
- Extra-fine wire, tinned copper strands
- core insulation: halogen-free compound
- Outer sheath:
TPE
PUR - Outer sheath: yellow (RAL 1023), black (RAL 9005)
Classification ETIM 5
- ETIM 5.0 Class-ID: EC000830
- ETIM 5.0 Class-Description: Data cable
Classification ETIM 6
- ETIM 6.0 Class-ID: EC000830
- ETIM 6.0 Class-Description: Data cable
Peak operating voltage
- 300 V (not for power applications)
Conductor resistance
- 1.5 mm²: max. 13.7 Ohm/km
- 2.5 mm²: max. 8.21 Ohm/km
Minimum bending radius
- Fixed installation: 12 mm
- Flexing without fixing: 24 mm
Flexing with fixing: 60 mm (15 x D)
Test voltage
- Core/core: 2000 V
Temperature range
- Fixed installation:
-40°C to +80°C (TPE +105°C) - Flexing – without fixing:
-30 °C to +70 °C (TPE +105 °C)