View larger
2170295 UNITRONIC BUS SAFETY 3X0,75 LAPP UNITRONIC BUS SAFETY 3X0,75
2170295
2170295
UNITRONIC BUS SAFETY 3X0,75
LAPP
1 m.
Cables > Data and communication cable
UNITRONIC BUS cabling
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Optimized for safety-critical communication loops, this Lapp 2170295 data cable connects specialized bus architectures within automated industrial installations. Safety bus lines ensure deterministic message exchange between safety controllers, emergency stops, and peripheral interlocks.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Core insulation: foam skin: Core insulation: foam skin
- Outer sheath: halogen-free, flame-retardant compound: Outer sheath: halogen-free, flame-retardant compound
- Outer sheath: yellow: Outer sheath: yellow
- Version UNITRONIC® BUS SAFETY FC: AWM Style 2464 (80°C 300 V): Version UNITRONIC® BUS SAFETY FC: AWM Style 2464 (80°C 300 V)
- (800 Hz): max. 45 nF/km: (800 Hz): max. 45 nF/km
- (loop): max. 52 ohm/km: (loop): max. 52 ohm/km
- Fixed installation: 5 x outer diameter: Fixed installation: 5 x outer diameter
- Core/core: 3000 V Core/core: 1500 V (FD- version): Core/core: 3000 V Core/core: 1500 V (FD- version)
- ETIM 5.0 Class-ID: EC000830: ETIM 5.0 Class-ID: EC000830
- ETIM 5.0 Class-Description: Data cable: ETIM 5.0 Class-Description: Data cable
- ETIM 6.0 Class-ID: EC000830: ETIM 6.0 Class-ID: EC000830
- ETIM 6.0 Class-Description: Data cable: ETIM 6.0 Class-Description: Data cable
More info
▲For systems e.g. SafetyBUS, based on CAN bus. Colour-coded in acc. with DIN 47100. Halogen free outer sheath, flame retardant. Temp. range from -40°C bis +80°C
Benefits
- For serial transmission of safety-oriented data
Application range
- UNITRONIC®BUS SAEFTY - fixed Installation
UNITRONIC®BUS SAEFTY FD P - highly flexible applications - For systems such as SafetyBUS p®, based on the well-known CAN bus system
Product features
- The stated bit rates result in the following cable lengths (maximum) for a bus segment:
- 500 kbit/s = max.100 m
- 250 kbit/s = max. 250 m
- 125 kbit/s = max. 500 m
- 50 kbit/s = max. 1,000 m
Norm references / Approvals
- Flame retardant acc. to IEC 60332-1-2
Product Make-up
- Bare stranded copper wires
- Core insulation: foam skin
- Tin-plated copper wire braiding
- Outer sheath: halogen-free, flame-retardant compound
- Outer sheath: yellow
Classification ETIM 5
- ETIM 5.0 Class-ID: EC000830
- ETIM 5.0 Class-Description: Data cable
Classification ETIM 6
- ETIM 6.0 Class-ID: EC000830
- ETIM 6.0 Class-Description: Data cable
Certifications
- Version UNITRONIC® BUS SAFETY FC:
AWM Style 2464 (80°C 300 V)
Mutual capacitance
- (800 Hz): max. 45 nF/km
Peak operating voltage
- (not for power applications) 250 V
Conductor resistance
- (loop): max. 52 ohm/km
Minimum bending radius
- Fixed installation:
5 x outer diameter
Test voltage
- Core/core: 3000 V
Core/core: 1500 V (FD- version)
Characteristic impedance
- 120 ohm
Temperature range
- UNITRONIC BUS SAFETY:
Fixed installation: -30°C to +80°C
UNITRONIC BUS SAFETY FD P:
Fixed installation -40°C to +80°C
Moved: -30 to +80°C