View larger
2170261 UNITRONIC BUS CAN 2X2X0,22 LAPP UNITRONIC BUS CAN 2X2X0,22
2170261
2170261
UNITRONIC BUS CAN 2X2X0,22
LAPP
1 m.
Cables > Data and communication cable
UNITRONIC BUS cabling
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
This Lapp 2170261 data cable serves as a specialized bus conduit designed to link CAN network devices across factory automation floors. Controller Area Network cabling provides high-integrity communication for distributed controllers, drives, and input/output modules.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Maximum bit rate: 1 Mbit/s for 40 m segment length: Maximum bit rate: 1 Mbit/s for 40 m segment length
- 0.22 + 0.34 + 0.5: bare stranded conductor, 7-wire 0.75: bare stranded conductor, fine-wire: 0.22 + 0.34 + 0.5: bare stranded conductor, 7-wire 0.75: bare stranded conductor, fine-wire
- Core insulation: foam skin: Core insulation: foam skin
- Outer sheath: PVC, violet (RAL 4001): Outer sheath: PVC, violet (RAL 4001)
- (loop): max. 186 ohm/km: (loop): max. 186 ohm/km
- Fixed installation: 8 x outer diameter: Fixed installation: 8 x outer diameter
- Core/core: 1500 V rms: Core/core: 1500 V rms
- Fixed installation: -30°C to +80°C: Fixed installation: -30°C to +80°C
- Flexing: -5°C to +70°C: Flexing: -5°C to +70°C
- ETIM 5.0 Class-ID: EC000830: ETIM 5.0 Class-ID: EC000830
- ETIM 5.0 Class-Description: Data cable: ETIM 5.0 Class-Description: Data cable
- ETIM 6.0 Class-ID: EC000830: ETIM 6.0 Class-ID: EC000830
- ETIM 6.0 Class-Description: Data cable: ETIM 6.0 Class-Description: Data cable
More info
▲For CAN based communication systems like CANopen, flame retardant acc. IEC 60332-1-2, temperature range from -40°C up to +80°C
CAN = Controller Area Network
Application range
- Fixed Installation
Product features
- Maximum bit rate: 1 Mbit/s for 40 m
segment length - Larger conductor cross-section is necessary with increasing length. Refer to the table below (reference values from ISO 11898).
- ISO 11898 makes recommendations for the segment length, cable cross section and bit rate
- Flame-retardant according IEC 60332-1-2
Norm references / Approvals
- Standardised internationally in ISO 11898
- UL/CSA type CMX (UL 444)
Product Make-up
- 0.22 + 0.34 + 0.5: bare stranded conductor, 7-wire
0.75: bare stranded conductor, fine-wire - Core insulation: foam skin
- Colour-coded in accordance with DIN 47100
- Copper braid
- Outer sheath: PVC, violet (RAL 4001)
Classification ETIM 5
- ETIM 5.0 Class-ID: EC000830
- ETIM 5.0 Class-Description: Data cable
Classification ETIM 6
- ETIM 6.0 Class-ID: EC000830
- ETIM 6.0 Class-Description: Data cable
Mutual capacitance
- (800 Hz) max. 40 nF/km
Peak operating voltage
- (not for power applications) 250 V
Conductor resistance
- (loop): max. 186 ohm/km
Minimum bending radius
- Fixed installation: 8 x outer diameter
Test voltage
- Core/core: 1500 V rms
Characteristic impedance
- 120 ohm
Temperature range
- Fixed installation: -30°C to +80°C
- Flexing: -5°C to +70°C