View larger
Images are for illustrative purposes only. Please refer to data sheet for details
2170260 UNITRONIC BUS CAN 1X2X0,22 LAPP UNITRONIC BUS CAN 1X2X0,22
2170260
2170260
UNITRONIC BUS CAN 1X2X0,22
LAPP
1 m.
UNITRONIC BUS CAN 1X2X0,22
UNITRONIC® BUS CAN
Cables > Data and communication cable
UNITRONIC BUS cabling
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteMore info
▲For CAN based communication systems like CANopen, flame retardant acc. IEC 60332-1-2, temperature range from -40°C up to +80°C
CAN = Controller Area Network
Application range
- Fixed Installation
Product features
- Maximum bit rate: 1 Mbit/s for 40 m
segment length - Larger conductor cross-section is necessary with increasing length. Refer to the table below (reference values from ISO 11898).
- ISO 11898 makes recommendations for the segment length, cable cross section and bit rate
- Flame-retardant according IEC 60332-1-2
Norm references / Approvals
- Standardised internationally in ISO 11898
- UL/CSA type CMX (UL 444)
Product Make-up
- 0.22 + 0.34 + 0.5: bare stranded conductor, 7-wire
0.75: bare stranded conductor, fine-wire - Core insulation: foam skin
- Colour-coded in accordance with DIN 47100
- Copper braid
- Outer sheath: PVC, violet (RAL 4001)
Classification ETIM 5
- ETIM 5.0 Class-ID: EC000830
- ETIM 5.0 Class-Description: Data cable
Classification ETIM 6
- ETIM 6.0 Class-ID: EC000830
- ETIM 6.0 Class-Description: Data cable
Mutual capacitance
- (800 Hz) max. 40 nF/km
Peak operating voltage
- (not for power applications) 250 V
Conductor resistance
- (loop): max. 186 ohm/km
Minimum bending radius
- Fixed installation: 8 x outer diameter
Test voltage
- Core/core: 1500 V rms
Characteristic impedance
- 120 ohm
Temperature range
- Fixed installation: -30°C to +80°C
- Flexing: -5°C to +70°C