View larger
1591222 A-2YF(L)2Y...ST III BD 10x2x0,8 LAPP A-2YF(L)2Y...ST III BD 10x2x0,8
1591222
1591222
A-2YF(L)2Y...ST III BD 10x2x0,8
LAPP
100 m.
Cables > Data and communication cable
UNITRONIC low frequency
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Constructed as an outdoor signal and telecommunication cable, this Lapp 1591222 component facilitates robust data transmission across external industrial plant networks. Communication lines deployed outdoors protect internal conductors from environmental exposure while maintaining signal integrity across long distances. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Outer sheath colour: black (RAL 9005)
- At 800 Hz: max. 52 nF/km
- K1: 98 % <400 pF/300 m
- K9-12: 98 % < 100 pF/300 m
- 0.6 mm: 0.28 mm²
- 0.8 mm: 0.50 mm²
- At 800 Hz 0.6 mm: approx. 1.0 dB/km
- At 800 Hz 0.8 mm: approx. 0.8 dB/km
- Core/core: 500 V
- Core/screen: 2000 V
- 0.6 mm: 130 ohm/km
- 0.8 mm: 73.2 ohm/km
- During installation: -20 °C to +50 °C After installation: ≤ +70 °C
- ETIM 5.0 Class-ID: EC000829
- ETIM 5.0 Class-Description: Signal-/telecommunications cable
- ETIM 6.0 Class-ID: EC000829
More info
▲A-2YF(L)2Y...ST III BD - Outdoor telecommunication cable VDE 0816, longitudinal and lateral watertightness, use as directly and indirectly buried/ burial cable
Application range
- External cables for telecommunication and data processing systems
- Do not install cables that are meant to be placed in ducts or for direct burial in areas exposed to fire hazards
Product features
- Outer sheath colour: black (RAL 9005)
- UV-resistant and laterally watertight
- Filled version (A-2YF(L)2Y...ST III BD) is addionally longitudinal watertight
Norm references / Approvals
- In accordance with DIN VDE 0816
Product Make-up
- Similar to A-2Y(L)2Y, but with petroleum-jelly filling, laminated sheath made of aluminium-coated plastic tape, and black PE outer sheath
Classification ETIM 5
- ETIM 5.0 Class-ID: EC000829
- ETIM 5.0 Class-Description: Signal-/telecommunications cable
Classification ETIM 6
- ETIM 6.0 Class-ID: EC000829
- ETIM 6.0 Class-Description: Signal-/telecommunications cable
Core identification code
- According to VDE 0816,
refer to Appendix T10
Mutual capacitance
- At 800 Hz: max. 52 nF/km
Coupling
- K1: 98 % <400 pF/300 m
- K9-12: 98 % < 100 pF/300 m
Conductor cross-section in
- 0.6 mm: 0.28 mm²
- 0.8 mm: 0.50 mm²
Cable attenuation/attenuation
- At 800 Hz 0.6 mm: approx. 1.0 dB/km
- At 800 Hz 0.8 mm: approx. 0.8 dB/km
Minimum bending radius
- 10 x outer diameter
Test voltage
- Core/core: 500 V
- Core/screen: 2000 V
Loop resistance
- 0.6 mm: 130 ohm/km
- 0.8 mm: 73.2 ohm/km
Temperature range
- During installation: -20 °C to +50 °C
After installation: ≤ +70 °C