LAPP 1591151 1591151 A-2Y(L)2Y...ST III BD 4x2x0,8 LAPP A-2Y(L)2Y...ST III BD 4x2x0,8 View larger
Images are for illustrative purposes only. Please refer to data sheet for details

1591151 A-2Y(L)2Y...ST III BD 4x2x0,8 LAPP A-2Y(L)2Y...ST III BD 4x2x0,8

1591151

1591151

A-2Y(L)2Y...ST III BD 4x2x0,8

LAPP

100 m.

A-2Y(L)2Y...ST III BD 4x2x0,8 A-2Y(L)2Y...ST III BD Telephone Outdoor Cable

Cables > Data and communication cable
UNITRONIC low frequency

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

The Lapp 1591151 signal and telecommunications cable is engineered for outdoor telephony and data transmission networks, routing voice and low-frequency signals across external installations and infrastructure. Its rugged physical properties protect internal conductors from moisture, environmental exposure, and mechanical stress during underground or aerial deployment.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Outer sheath colour: black (RAL 9005)
  • At 800 Hz: max. 52 nF/km
  • K1: 98 % <400 pF/300 m
  • K9-12: 98 % < 100 pF/300 m
  • 0.6 mm: 0.28 mm²
  • 0.8 mm: 0.50 mm²
  • At 800 Hz 0.6 mm: approx. 1.04 dB/km
  • At 800 Hz 0.8 mm: approx. 0.78 dB/km
  • Core/core: 500 V
  • Core/screen: 2000 V
  • 0.6 mm: 130 ohm/km
  • 0.8 mm: 73.2 ohm/km
  • During installation: -20 °C to +50 °C After installation: ≤ +70 °C
  • ETIM 5.0 Class-ID: EC000829
  • ETIM 5.0 Class-Description: Signal-/telecommunications cable
  • ETIM 6.0 Class-ID: EC000829

More info

▲

A-2Y(L)2Y...ST III BD - Outdoor telecommunication cable according to VDE 0816, specially layered jacket for use as directly and indirectly buried/ burial cable

Application range

  • External cables for telecommunication and data processing systems
  • Do not install cables that are meant to be placed in ducts or for direct burial in areas exposed to fire hazards

Product features

  • Outer sheath colour: black (RAL 9005)
  • UV-resistant and laterally watertight
  • Filled version (A-2YF(L)2Y...ST III BD) is addionally longitudinal watertight

Norm references / Approvals

  • In accordance with DIN VDE 0816

Product Make-up

  • Solid bare copper conductor
  • Core insulation made of polyethylene (PE)
  • 5 star-quads are twisted into each basic unit, which is then twisted together with the main unit to form the cable core
  • Paper tape wrapping
  • Laminated sheath with aluminium-coated plastic tape, PE outer sheath

Classification ETIM 5

  • ETIM 5.0 Class-ID: EC000829
  • ETIM 5.0 Class-Description: Signal-/telecommunications cable

Classification ETIM 6

  • ETIM 6.0 Class-ID: EC000829
  • ETIM 6.0 Class-Description: Signal-/telecommunications cable

Core identification code

  • According to VDE 0816,
    refer to Appendix T10

Mutual capacitance

  • At 800 Hz: max. 52 nF/km

Coupling

  • K1: 98 % <400 pF/300 m
  • K9-12: 98 % < 100 pF/300 m

Conductor cross-section in

  • 0.6 mm: 0.28 mm²
  • 0.8 mm: 0.50 mm²

Cable attenuation/attenuation

  • At 800 Hz 0.6 mm: approx. 1.04 dB/km
  • At 800 Hz 0.8 mm: approx. 0.78 dB/km

Minimum bending radius

  • 10 x outer diameter

Test voltage

  • Core/core: 500 V
  • Core/screen: 2000 V

Loop resistance

  • 0.6 mm: 130 ohm/km
  • 0.8 mm: 73.2 ohm/km

Temperature range

  • During installation: -20 °C to +50 °C
    After installation: ≤ +70 °C

Product Datasheet