15381005 ÖLFLEX TRAIN 381 3,6kV 1X25 LAPP ÖLFLEX TRAIN 381 3,6kV 1X25
15381005
15381005
ÖLFLEX TRAIN 381 3,6kV 1X25
LAPP
1 m.
ÖLFLEX TRAIN 381 3,6kV 1X25
ÖLFLEX® TRAIN 381 3,6kV
Cables > Power cable >= 1 kV, for permanent installation
ÖLFLEX TRAIN
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteMore info
▲Benefits
- High electrical strength and mechanical durability due to dual-layer cable construction
- Good chemical resistance please see Appendix T1
- Resistant to mechanical influences in harsh environmental conditions
- Extended temperature range
- Reduced flame spreading increases the protection against damage to persons and property in the event of a fire
Application range
- For use in railway vehicles, for fixed installations and applications where limited movement may occur
- Suitable for wiring of control cabinets, distributors, converters, motors and batteries
- Also applicable within oily environments and areas with increased ambient temperature
Product features
- Fire behaviour according to EN/IEC:
- Halogen-free acc. to EN 60754-1
- No corrosive gases acc. to EN 60754-2
- No fluorine acc. to EN 60684-2
- No toxic gases acc. to EN 50305
- Low smoke density acc. to EN 61034-2
- Flame-retardant acc. to EN 60332-1-2
- No flame propagation acc. to
EN 60332-3-24 / EN 60332-3-25 /
EN 50305 - Fire behaviour according to NF:
- Toxicity of gases acc. to NF X 70-100
- Low smoke density acc. to NF X 10-702
- No flame propagation acc. to NF C 32-070,
Cat. C1 and C2 - Chemical properties:
- Oil resistant acc. to EN 50264-3-1
- Fuel resistant acc. to EN 50264-3-1
- Acid resistant acc. to EN 50264-3-1
- Alkali resistant acc. to EN 50264-3-1
- Ozone resistant acc. to EN 50264-3-1/
EN 50305) - Current rating according to EN 50355, appendix A
Norm references / Approvals
- EN 50382-2 type FF
- EN 45545-2 HL1, HL2, HL3
- NF F 16-101 - Classification: C / F1
(flame propagation / smoke)
Product Make-up
- Tinned-copper strand, fine-wire
- Insulation: Electron beam cross-linked Polymer compound EI 109
- Outer sheath: electron beam cross-linked polymer-compound EM 104
- Outer sheath colour: Black
Classification ETIM 5
- ETIM 5.0 Class-ID: EC000057
- ETIM 5.0 Class-Description: Low voltage power cable
Classification ETIM 6
- ETIM 6.0 Class-ID: EC000057
- ETIM 6.0 Class-Description: Low voltage power cable
Conductor stranding
- Fine-wired/ Finely stranded according to IEC 60228, conductor class 5
Minimum bending radius
- Fixed installation:
≤ 12 mm: 3 x OD
> 12 mm: 4 x OD - Occasional flexing:
≤ 12 mm: 4 x OD
> 12 mm ≤ 20 mm: 5 x OD
> 20 mm: 6 x OD
(OD = outer diameter)
Nominal voltage
- U0/U AC 3,6/6 kV
- UmAC 7,2 kV
V0DC 5,4 kV
Test voltage
- 11 kV AC; 26 kV DC
Temperature range
- Fixed installation:
-45°C to +120°C (20.000 h)
-50°C acc. to GOST 20.57.406-81 - Occasional flexing:
-35°C to +90°C
Short circuit: +200°C (5s)