High electrical strength and mechanical durability due to dual-layer cable construction
Good chemical resistance please see Appendix T1
Resistant to mechanical influences in harsh environmental conditions
Extended temperature range
Reduced flame spreading increases the protection against damage to persons and property in the event of a fire
Application range
For use in railway vehicles, for fixed installations and applications where limited movement may occur
Suitable for wiring of control cabinets, distributors, converters, motors and batteries
Also applicable within oily environments and areas with increased ambient temperature
Product features
Fire behaviour according to EN/IEC: - Halogen-free acc. to EN 60754-1 - No corrosive gases acc. to EN 60754-2 - No fluorine acc. to EN 60684-2 - No toxic gases acc. to EN 50305 - Low smoke density acc. to EN 61034-2 - Flame-retardant acc. to EN 60332-1-2 - No flame propagation acc. to EN 60332-3-24 / EN 60332-3-25 / EN 50305
Fire behaviour according to NF: - Toxicity of gases acc. to NF X 70-100 - Low smoke density acc. to NF X 10-702 - No flame propagation acc. to NF C 32-070, Cat. C1 and C2
Chemical properties: - Oil resistant acc. to EN 50264-3-1 - Fuel resistant acc. to EN 50264-3-1 - Acid resistant acc. to EN 50264-3-1 - Alkali resistant acc. to EN 50264-3-1 - Ozone resistant acc. to EN 50264-3-1/ EN 50305)
Current rating according to EN 50355, appendix A
Norm references / Approvals
EN 50382-2 type FF
EN 45545-2 HL1, HL2, HL3
NF F 16-101 - Classification: C / F1 (flame propagation / smoke)
Product Make-up
Tinned-copper strand, fine-wire
Insulation: Electron beam cross-linked Polymer compound EI 109
Outer sheath: electron beam cross-linked polymer-compound EM 104
Outer sheath colour: Black
Classification ETIM 5
ETIM 5.0 Class-ID: EC000057
ETIM 5.0 Class-Description: Low voltage power cable
Classification ETIM 6
ETIM 6.0 Class-ID: EC000057
ETIM 6.0 Class-Description: Low voltage power cable
Conductor stranding
Fine-wired/ Finely stranded according to IEC 60228, conductor class 5
Minimum bending radius
Fixed installation: ≤ 12 mm: 3 x OD > 12 mm: 4 x OD
Occasional flexing: ≤ 12 mm: 4 x OD > 12 mm ≤ 20 mm: 5 x OD > 20 mm: 6 x OD (OD = outer diameter)
Nominal voltage
U0/U AC 1.8/3 kV
UmAC 3,6 kV V0DC 2,7 kV
Test voltage
6,5 kV AC; 15 kV DC
Temperature range
Fixed installation: -45°C to +120°C (20.000 h) -50°C acc. to GOST 20.57.406-81
Occasional flexing: -35°C to +90°C Short circuit: +200°C (5s)
Product Datasheet
Electrica Online Product DatasheetPrepared from the current product description, catalog data and structured technical attributes.