View larger
15361008 ÖLFLEX TRAIN 361 1,8kV 1X50 BK LAPP ÖLFLEX TRAIN 361 1,8kV 1X50 BK
15361008
15361008
ÖLFLEX TRAIN 361 1,8kV 1X50 BK
LAPP
1 m.
Cables > Power cable >= 1 kV, for permanent installation
ÖLFLEX TRAIN
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Engineered for demanding environments, this Lapp 15361008 single core cable provides reliable power transmission for heavy-duty electrical networks and transportation infrastructure. Such conductors are routinely deployed in fixed wiring layouts, distribution boards, and industrial machinery requiring robust insulation properties. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- NF F 16-101 - Classification: C / F1 (flame propagation / smoke)
- Insulation: Electron beam cross-linked Polymer compound EI 109
- Colour: Black
- Fixed installation: ≤ 12 mm: 3 x OD > 12 mm: 4 x OD
- Occasional flexing: ≤ 12 mm: 4 x OD > 12 mm ≤ 20 mm: 5 x OD > 20 mm: 6 x OD (OD = outer diameter)
- Fixed installation: -45°C to +120°C (20.000 h) -50°C acc. to GOST 20.57.406-81
- Occasional flexing: -35°C to +90°C Short circuit: +200°C (5s)
- ETIM 5.0 Class-ID: EC000993
- ETIM 5.0 Class-Description: Single core cable
- ETIM 6.0 Class-ID: EC000993
- ETIM 6.0 Class-Description: Single core cable
More info
▲Benefits
- Good chemical resistance please see Appendix T1
- Resistant to mechanical influences in harsh environmental conditions
- Extended temperature range
- Reduced flame spreading increases the protection against damage to persons and property in the event of a fire
Application range
- For use in railway vehicles, for fixed installations and applications where limited movement may occur
- Suitable for connecting lamps, heating equipment, switchgear, terminal boxes and power supply
- Also applicable within oily environments and areas with increased ambient temperature
Product features
- Fire behaviour according to EN/IEC:
- Halogen-free acc. to EN 60754-1
- No corrosive gases acc. to EN 60754-2
- No fluorine acc. to EN 60684-2
- No toxic gases acc. to EN 50305
- Low smoke density acc. to EN 61034-2
- Flame-retardant acc. to EN 60332-1-2
- No flame propagation acc. to
EN 60332-3-24 / EN 60332-3-25 /
EN 50305 - Fire behaviour according to NF:
- Toxicity of gases acc. to NF X 70-100
- Low smoke density acc. to NF X 10-702
- No flame propagation acc. to NF C 32-070,
Cat. C1 and C2 - Chemical properties:
- Oil resistant acc. to EN 50264-3-1
- Fuel resistant acc. to EN 50264-3-1
- Acid resistant acc. to EN 50264-3-1
- Alkali resistant acc. to EN 50264-3-1
- Ozone resistant acc. to EN 50264-3-1/
EN 50305) - Current rating according to EN 50355, appendix A
Norm references / Approvals
- EN 50264-3-1 type M
- EN 45545-2 HL1, HL2, HL3
- NF F 16-101 - Classification: C / F1
(flame propagation / smoke)
Product Make-up
- Tinned-copper strand, fine-wire
- Insulation: Electron beam cross-linked Polymer compound EI 109
- Colour: Black
Classification ETIM 5
- ETIM 5.0 Class-ID: EC000993
- ETIM 5.0 Class-Description: Single core cable
Classification ETIM 6
- ETIM 6.0 Class-ID: EC000993
- ETIM 6.0 Class-Description: Single core cable
Conductor stranding
- Fine-wired/ Finely stranded according to IEC 60228, conductor class 5
Minimum bending radius
- Fixed installation:
≤ 12 mm: 3 x OD
> 12 mm: 4 x OD - Occasional flexing:
≤ 12 mm: 4 x OD
> 12 mm ≤ 20 mm: 5 x OD
> 20 mm: 6 x OD
(OD = outer diameter)
Nominal voltage
- U0/U AC 1.8/3 kV
- UmAC 3,6 kV
V0DC 2,7 kV
Test voltage
- 6,5 kV AC; 15 kV DC
Temperature range
- Fixed installation:
-45°C to +120°C (20.000 h)
-50°C acc. to GOST 20.57.406-81 - Occasional flexing:
-35°C to +90°C
Short circuit: +200°C (5s)