Outfit railway rolling stock and demanding transit systems with the Lapp 15350004 control cable. Specialized multi-core cables of this standard provide resilient signal and power transmission under extreme thermal stress and continuous mechanical movement. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- High temperature resistance: -50°C up to 120°C
- NF F 16-101 - Classification: C / F0 (flame propagation / smoke)
- Insulation: Electron beam cross-linked Polymer compound EI 109
- Colour of insulation: Black with white numbers
- Outer sheath: electron beam cross-linked polymer-compound EM 104
- Outer sheath colour: Black
- Fixed installation: ≤ 12 mm: 3 x OD > 12 mm: 4 x OD
- Occasional flexing: ≤ 12 mm: 4 x OD > 12 mm ≤ 20 mm: 5 x OD > 20 mm: 6 x OD (OD = outer diameter)
- U0/U: 300/500 V
- Fixed installation: -45°C to +120°C (20.000 h) -50°C acc. to GOST 20.57.406-81
- Occasional flexing: -35°C to +90°C Short circuit: +200°C (5s)
- ETIM 5.0 Class-ID: EC000104
- ETIM 5.0 Class-Description: Control cable
- ETIM 6.0 Class-ID: EC000104
- ETIM 6.0 Class-Description: Control cable
More info
▲ÖLFLEX® TRAIN 350 300V - Control cable EN 50264-3-2 MM, 300/500V for high requirements in railways/rolling stock; EN 45545: HL1-HL3, NF F 16-101: C/F0
- Meets EN 50264-3-2 type MM and
EN 45545-2 - High temperature resistance: -50°C up to 120°C
- Highly oil- and fuel-resistant
Benefits
- Good chemical resistance please see Appendix T1
- Resistant to mechanical influences in harsh environmental conditions
- Extended temperature range
- Reduced flame spreading increases the protection against damage to persons and property in the event of a fire
Application range
- For use in railway vehicles and buses, for fixed installations and applications where limited movement may occur
- Suitable for connecting lamps, heating equipment, switchgear, terminal boxes and power supply
- For use in railway vehicles, for fixed installations and applications where limited movement may occur
Product features
- Fire behaviour according to EN/IEC:
- Halogen-free acc. to EN 60754-1
- No corrosive gases acc. to EN 60754-2
- No fluorine acc. to EN 60684-2
- No toxic gases acc. to EN 50305
- Low smoke density acc. to EN 61034-2
- Flame-retardant acc. to EN 60332-1-2
- No flame propagation acc. to
EN 60332-3-24 / EN 60332-3-25 /
EN 50305 - Fire behaviour according to NF:
- Toxicity of gases acc. to NF X 70-100
- Low smoke density acc. to NF X 10-702
- No flame propagation acc. to NF C 32-070,
Cat. C1 and C2 - Chemical properties:
- Oil resistant acc. to EN 50264-3-2
- Fuel resistant acc. to EN 50264-3-2
- Acid resistant acc. to EN 50264-3-2
- Alkali resistant acc. to EN 50264-3-2
- Ozone resistant acc. to EN 50264-3-2/
EN 50305) - Current rating according to EN 50355, appendix A
Norm references / Approvals
- EN 50264-3-2 type MM
- EN 45545-2 HL1, HL2, HL3
- NF F 16-101 - Classification: C / F0
(flame propagation / smoke)
Product Make-up
- Tinned-copper strand, fine-wire
- Insulation: Electron beam cross-linked Polymer compound EI 109
- Colour of insulation: Black with white numbers
- Outer sheath: electron beam cross-linked polymer-compound EM 104
- Outer sheath colour: Black
Classification ETIM 5
- ETIM 5.0 Class-ID: EC000104
- ETIM 5.0 Class-Description: Control cable
Classification ETIM 6
- ETIM 6.0 Class-ID: EC000104
- ETIM 6.0 Class-Description: Control cable
Core identification code
- Black with white numbers
Conductor stranding
- Fine-wired/ Finely stranded according to IEC 60228, conductor class 5
Minimum bending radius
- Fixed installation:
≤ 12 mm: 3 x OD
> 12 mm: 4 x OD - Occasional flexing:
≤ 12 mm: 4 x OD
> 12 mm ≤ 20 mm: 5 x OD
> 20 mm: 6 x OD
(OD = outer diameter)
Nominal voltage
- U0/U: 300/500 V
- UmAC 600 V
V0DC 450 V
Test voltage
- 2,0 kV AC; 4,8 kV DC
Protective conductor
- G = with GN-YE protective conductor
X = without protective conductor
Temperature range
- Fixed installation:
-45°C to +120°C (20.000 h)
-50°C acc. to GOST 20.57.406-81 - Occasional flexing:
-35°C to +90°C
Short circuit: +200°C (5s)