View larger
15345028 ÖLFLEX TRAIN 345 C 600V 4G2,5 LAPP ÖLFLEX TRAIN 345 C 600V 4G2,5
15345028
15345028
ÖLFLEX TRAIN 345 C 600V 4G2,5
LAPP
1 m.
Cables > Power cable >= 1 kV, for permanent installation
ÖLFLEX TRAIN
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Serving as a specialized control cable, the Lapp 15345028 ÖLFLEX TRAIN 345 C 600V 4G2,5 coordinates data and low-voltage communication in complex systems. Control cables enable precise signal routing between automated controllers, sensors, and actuators in industrial plants. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- High temperature resistance: -50°C up to 120°C
- Conductor: Fine-wire strands of tinned copper
- Insulation: Electron beam cross-linked Polymer compound EI 109
- Screen: Tinned-copper braiding
- Outer sheath colour: Black
More info
▲ÖLFLEX® TRAIN 345 C 600V - Control cable screened EN 50264-3-2 MM S 0,6/1kV for high requirements in railways/rolling stock; EN 45545: HL1-HL3, NF F 16-101: C/F0
- Meets EN 50264-3-2 type MM S and
EN 45545-2 - High temperature resistance: -50°C up to 120°C
- Highly oil- and fuel-resistant
Benefits
- Copper screening complies with EMC requirements and protects against electromagnetic interference
- Good chemical resistance please see Appendix T1
- Resistant to mechanical influences in harsh environmental conditions
- Extended temperature range
- Reduced flame spreading increases the protection against damage to persons and property in the event of a fire
Application range
- For use in railway vehicles, for fixed installations and applications where limited movement may occur
- Suitable for connecting lamps, heating equipment, switchgear, terminal boxes and power supply
- Also applicable within oily environments and areas with increased ambient temperature
Product features
- Fire behaviour according to EN/IEC:
- Halogen-free acc. to EN 60754-1
- No corrosive gases acc. to EN 60754-2
- No fluorine acc. to EN 60684-2
- No toxic gases acc. to EN 50305
- Low smoke density acc. to EN 61034-2
- Flame-retardant acc. to EN 60332-1-2
- No flame propagation acc. to
EN 60332-3-24 / EN 60332-3-25 /
EN 50305 - Fire behaviour according to NF:
- Toxicity of gases acc. to NF X 70-100
- Low smoke density acc. to NF X 10-702
- No flame propagation acc. to NF C 32-070,
Cat. C1 and C2 - Chemical properties:
- Oil resistant acc. to EN 50264-3-2
- Fuel resistant acc. to EN 50264-3-2
- Acid resistant acc. to EN 50264-3-2
- Alkali resistant acc. to EN 50264-3-2
- Ozone resistant acc. to EN 50264-3-2/
EN 50305) - Current rating according to EN 50355, appendix A
Norm references / Approvals
- EN 50264-3-2 type MM S
- EN 45545-2 HL1, HL2, HL3
- NF F 16-101 - Classification: C / F0
(flame propagation / smoke)
Product Make-up
- Conductor: Fine-wire strands of tinned copper
- Insulation: Electron beam cross-linked Polymer compound EI 109
- Colour of insulation: Black with white numbers
- Wrapping: Halogen-free plastic foil
- Screen: Tinned-copper braiding
- Outer sheath: electron beam cross-linked polymer-compound EM 104
- Outer sheath colour: Black
Classification ETIM 5
- ETIM 5.0 Class-ID: EC000104
- ETIM 5.0 Class-Description: Control cable
Classification ETIM 6
- ETIM 6.0 Class-ID: EC000104
- ETIM 6.0 Class-Description: Control cable
Core identification code
- Black with white numbers
Conductor stranding
- Fine-wired/ Finely stranded according to IEC 60228, conductor class 5
Minimum bending radius
- Fixed installation:
≤ 12 mm: 3 x OD
> 12 mm: 4 x OD - Occasional flexing:
≤ 12 mm: 4 x OD
> 12 mm ≤ 20 mm: 5 x OD
> 20 mm: 6 x OD
(OD = outer diameter)
Nominal voltage
- U0/U AC 0.6/1 kV
- UmAC 1.2 kV
V0DC 0.9 kV
Test voltage
- 3,5 kV AC; 8,4 kV DC
Protective conductor
- G = with GN-YE protective conductor
X = without protective conductor
Temperature range
- Fixed installation:
-45°C to +120°C (20.000 h)
-50°C acc. to GOST 20.57.406-81 - Occasional flexing:
-35°C to +90°C
Short circuit: +200°C (5s)