The Lapp 15331020 ÖLFLEX TRAIN 331 600V 1X4 GNYE functions as a specialized single core cable for protective earth and grounding applications. Grounding lines are installed across electrical systems to ensure safety and compliance with industrial standards. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- High temperature resistance: -50°C up to 120°C
- NF F 16-101 - Classification: C / F0 (flame propagation / smoke)
- Insulation: Electron beam cross-linked Polymer compound EI 109
- ETIM 5.0 Class-Description: Single core cable
- ETIM 6.0 Class-Description: Single core cable
More info
▲ÖLFLEX® TRAIN 331 600V - Single-core EN 50264-3-1 M, 0,6/1kV for high requirements in railways/rolling stock; EN 45545: HL1-HL3, NF F 16-101: C/F0, NFPA 130
- Meets EN 50264-3-1 type M and
EN 45545-2 - High temperature resistance: -50°C up to 120°C
- Also available in red, blue and further colours
Benefits
- Good chemical resistance please see Appendix T1
- Resistant to mechanical influences in harsh environmental conditions
- Extended temperature range
- Reduced flame spreading increases the protection against damage to persons and property in the event of a fire
Application range
- For use in railway vehicles, for fixed installations and applications where limited movement may occur
- Suitable for connecting lamps, heating equipment, switchgear, terminal boxes and power supply
- Also applicable within oily environments and areas with increased ambient temperature
Product features
- Fire behaviour according to EN/IEC:
- Halogen-free acc. to EN 60754-1
- No corrosive gases acc. to EN 60754-2
- No fluorine acc. to EN 60684-2
- No toxic gases acc. to EN 50305
- Low smoke density acc. to EN 61034-2
- Flame-retardant acc. to EN 60332-1-2
- No flame propagation acc. to
EN 60332-3-24 / EN 60332-3-25 /
EN 50305 - Fire behaviour according to NF (item-specific, refer to data sheet):
- Toxicity of gases acc. to NF X 70-100
- Low smoke density acc. to NF X 10-702
- No flame propagation acc. to NF C 32-070,
Cat. C1 and C2 - Chemical properties:
- Oil resistant acc. to EN 50264-3-1
- Fuel resistant acc. to EN 50264-3-1
- Acid resistant acc. to EN 50264-3-1
- Alkali resistant acc. to EN 50264-3-1
- Ozone resistant acc. to EN 50264-3-1/
EN 50305) - Current rating according to EN 50355, appendix A
Norm references / Approvals
- EN 50264-3-1 type M
- EN 45545-2 HL1, HL2, HL3
- NF F 16-101 - Classification: C / F0
(flame propagation / smoke) - Compliant with NFPA 130
Product Make-up
- Tinned-copper strand, fine-wire
- Insulation: Electron beam cross-linked Polymer compound EI 109
- Colour: Refer to item list
Classification ETIM 5
- ETIM 5.0 Class-ID: EC000993
- ETIM 5.0 Class-Description: Single core cable
Classification ETIM 6
- ETIM 6.0 Class-ID: EC000993
- ETIM 6.0 Class-Description: Single core cable
Conductor stranding
- Fine-wired/ Finely stranded according to IEC 60228, conductor class 5
Minimum bending radius
- Fixed installation:
≤ 12 mm: 3 x OD
> 12 mm: 4 x OD - Occasional flexing:
≤ 12 mm: 4 x OD
> 12 mm ≤ 20 mm: 5 x OD
> 20 mm: 6 x OD
(OD = outer diameter)
Nominal voltage
- U0/U AC 0.6/1 kV
- UmAC 1.2 kV
V0DC 0.9 kV
Test voltage
- 3,5 kV AC; 8,4 kV DC
Temperature range
- Fixed installation:
-45°C to +120°C (20.000 h)
-50°C acc. to GOST 20.57.406-81 - Occasional flexing:
-35°C to +90°C
Short circuit: +200°C (5s)