Resistant to mechanical influences in harsh environmental conditions
Extended temperature range
Reduced flame spreading increases the protection against damage to persons and property in the event of a fire
Application range
For use in railway vehicles, for fixed installations and applications where limited movement may occur
Suitable for control and monitoring circuits as well as locking circuits and internal wiring of equipment in trains and locomotives
Also applicable within oily environments and areas with increased ambient temperature
Product features
Fire behaviour according to EN/IEC: - Halogen-free acc. to EN 60754-1 - No corrosive gases acc. to EN 60754-2 - No fluorine acc. to EN 60684-2 - No toxic gases acc. to EN 50305 - Low smoke density acc. to EN 61034-2 - Flame-retardant acc. to EN 60332-1-2 - No flame propagation acc. to EN 60332-3-24 / EN 60332-3-25 / EN 50305
Fire behaviour according to NF: - Toxicity of gases acc. to NF X 70-100 - Low smoke density acc. to NF X 10-702 - No flame propagation acc. to NF C 32-070, Cat. C1 and C2
Chemical properties: - Oil resistant acc. to EN 50306 - Fuel resistant acc. to EN 50306 - Acid resistant acc. to EN 50306 - Alkali resistant acc. to EN 50306 - Ozone resistant acc. to EN 50306
Current rating according to EN 50355, appendix A
Norm references / Approvals
EN 50306-4 class E, type MM
EN 45545-2 HL1, HL2, HL3
NF F 16-101 - Classification: C / F0 (flame propagation / smoke)
Product Make-up
Tinned-copper strand, 19 or 37 wires, SRC (Special Round Conductor)
Insulation: Electron beam cross-linked Polymer compound acc. to EN 50306
Colour of insulation: White with black numbers
Outer sheath: electron beam cross-linked polymer-compound S2 acc. to EN 50306
Outer sheath colour: Black
Classification ETIM 5
ETIM 5.0 Class-ID: EC000104
ETIM 5.0 Class-Description: Control cable
Classification ETIM 6
ETIM 6.0 Class-ID: EC000104
ETIM 6.0 Class-Description: Control cable
Core identification code
White with black numbers
Conductor stranding
SRC (special round conductor) 19 or 37 wires acc. to EN 50306-1
Minimum bending radius
Fixed installation: ≤ 12 mm: 4 x OD / 3 x OD* > 12 mm: 5 x OD / 4 x OD* * for careful bending, once at connecting terminal
Occasional flexing: ≤ 12 mm: 5 x OD > 12 mm: 6 x OD (OD = outer diameter)
Nominal voltage
U0: 600 V AC U0/U: 300/500 V AC acc. to EN 50306 Um: 550 V AC
Test voltage
3,5 kV AC; 8,4 kV DC
Protective conductor
G = with GN-YE protective conductor X = without protective conductor
Temperature range
Fixed installation: -45°C to +125°C (20.000 h) -50°C acc. to GOST 20.57.406-81
Occasional flexing: -35°C to +105°C Short circuit: +160°C (5s)
Product Datasheet
Electrica Online Product DatasheetPrepared from the current product description, catalog data and structured technical attributes.