LAPP 1123478 1123478 ÖLFLEX CLASSIC 135 CH BK 0,6/1 kV 4G2,5 LAPP ÖLFLEX CLASSIC 135 CH BK 0,6/1 kV 4G2,5 View larger
Images are for illustrative purposes only. Please refer to data sheet for details

1123478 ÖLFLEX CLASSIC 135 CH BK 0,6/1 kV 4G2,5 LAPP ÖLFLEX CLASSIC 135 CH BK 0,6/1 kV 4G2,5

1123478

1123478

ÖLFLEX CLASSIC 135 CH BK 0,6/1 kV 4G2,5

LAPP

1 m.

ÖLFLEX CLASSIC 135 CH BK 0,6/1 kV 4G2,5 ÖLFLEX® CLASSIC 135 CH BK 0,6/1 kV

Cables > Power cable 1 kV, for moving application
ÖLFLEX environment, numbered cores

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

The Lapp 1123478 ÖLFLEX CLASSIC 135 CH BK 0,6/1 kV 4G2,5 low voltage power cable incorporates halogen-free materials to enhance safety in public infrastructure and sensitive indoor spaces. Halogen-free industrial cables prevent toxic smoke emission during thermal events while delivering reliable power distribution throughout modern buildings. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • CPR: Article number choice under www.lappkabel.com/cpr
  • UL AWM approval: refer to data sheet
  • Core insulation: Halogen-free
  • Up to 5 cores: colour-coded according to VDE 0293-308, refer to Appendix T9
  • From 6 cores: black with white numbers
  • Occasional flexing: 20 x outer diameter
  • Fixed installation: 6 x outer diameter
  • U0/U: 600/1000 V
  • UL: 1000 V
  • Core/core: 4000 V
  • Core/screen: 2000 V
  • Occasional flexing: -25°C to +70°C Fixed installation: -40°C to +80°C
  • UL: -25°C to +75°C
  • ETIM 5.0 Class-ID: EC000057
  • ETIM 5.0 Class-Description: Low voltage power cable
  • ETIM 6.0 Class-ID: EC000057

More info

▲

ÖLFLEX® CLASSIC 135 CH BK 0,6/1kV: Power and Control Cable UL AWM Style 21156 Class 5, Screened, Halogen-free/ Highly Flame Retardant, Public buildings, Outdoor

  • CPR: Article number choice under www.lappkabel.com/cpr
  • Public buildings
  • EMC/Screened

Benefits

  • Easy handling and installation due to flexible design
  • Space-saving installation due to small cable diameters

Application range

  • Plant engineering
    Industrial machinery
    Heating and air-conditioning systems
  • Particularly where human and animal life as well as valuable property are exposed to high risk of fire hazards
  • For outdoor applications
  • According to NFPA 79, subchapter 12.9.2: Use for industrial machinery operated in the USA on the basis of UL AWM (recognized) certification
  • Each dimension with nominal/ minimum average wall thickness of the outer sheath of at least 1.8 mm: For applications where a strengthened outer sheath may turn out to be advantageous

Product features

  • Flame-retardant according to IEC 60332-1-2
    (flame spread on a single cable)
  • No flame-propagation according to IEC 60332-3-24 respectively IEC 60332-3-25 (Flame spread on vertical cable or wire bundle)
  • Halogen-free according to IEC 60754-1
    (amount of halogen acid gas)
    Corrosiveness of combustion gases according to IEC 60754-2 (degree of acidity)
  • Low smoke density according to IEC 61034-2
  • UV and weather-resistant according to ISO 4892-2
  • Ozone-resistant according to EN 50396

Norm references / Approvals

  • Based on EN 50525-3-11
  • UL AWM approval: refer to data sheet

Product Make-up

  • Fine-wire strand made of bare copper wires
  • Core insulation: Halogen-free
  • Halogen-free plastic foil wrapping
  • Tinned-copper braiding
  • Outer sheath made of special halogen-free coumpound, black

Classification ETIM 5

  • ETIM 5.0 Class-ID: EC000057
  • ETIM 5.0 Class-Description: Low voltage power cable

Classification ETIM 6

  • ETIM 6.0 Class-ID: EC000057
  • ETIM 6.0 Class-Description: Low voltage power cable

Core identification code

  • Up to 5 cores: colour-coded according to VDE 0293-308, refer to Appendix T9
  • From 6 cores: black with white numbers

Conductor stranding

  • Fine wire according to VDE 0295,
    class 5/IEC 60228 class 5

Minimum bending radius

  • Occasional flexing: 20 x outer diameter
  • Fixed installation: 6 x outer diameter

Nominal voltage

  • U0/U: 600/1000 V
  • UL: 1000 V

Test voltage

  • Core/core: 4000 V
  • Core/screen: 2000 V

Protective conductor

  • G = with GN-YE protective conductor
  • X = without protective conductor

Temperature range

  • Occasional flexing: -25°C to +70°C
    Fixed installation: -40°C to +80°C
  • UL: -25°C to +75°C

Product Datasheet