View larger
1027301 ÖLFLEX FD 891 CY 4G1/18 AWG LAPP ÖLFLEX FD 891 CY 4G1/18 AWG
1027301
1027301
ÖLFLEX FD 891 CY 4G1/18 AWG
LAPP
1 m.
Cables > Power cable less 1 kV, for moving application
ÖLFLEX FD cabling
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Manufactured by Lapp, the 1027301 ÖLFLEX FD 891 CY 4G1/18 AWG LAPP ÖLFLEX FD 891 CY 4G1/18 AWG is a continuous-flex control cable with overall copper screening built for automated production lines. Robotic equipment and high-speed drag chains depend on shielded flexible wiring to prevent signal degradation during intense cyclical motion. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- For use in power chains: Please comply with assembly guideline Appendix T3
- Core insulation: PVC
- Flexing: up from 7.5 x outer diameter
- Fixed installation: 4 x outer diameter
- IEC: U 0 /U 300/500 V
- UL/CSA: 600 V
- Flexing: -5°C to +70°C (UL: +90°C)
- Fixed installation: -40°C to +70°C (UL: +90°C)
- ETIM 5.0 Class-ID: EC000104
- ETIM 5.0 Class-Description: Control cable
- ETIM 6.0 Class-ID: EC000104
- ETIM 6.0 Class-Description: Control cable
More info
▲ÖLFLEX® FD 891 CY - Screened power and control cable for versatile use in power chains with UL/cUL AWM certification.
- Core Line Performance - Medium to increased travel lengths or acceleration
- AWM certification for USA and Canada
- EMC compliant copper screening
Benefits
- Multi-standard certification reduces part varieties and saves costs
- Certified for the USA and Canada for export-oriented machine, appliance and apparatus manufacturers
- Under consideration of the temperature range also suitable for flexible outdoor use
- Copper screening complies with EMC requirements and protects against electromagnetic interference
Application range
- In power chains or moving machine parts
- Suitable for use in measuring, control and regulating circuits
- Assembly lines, production lines, in all kinds of machines
- Machine tools
- Plant engineering
Product features
- Flame-retardant according to IEC 60332-1-2 & CSA FT1
- Oil-resistant
- Low-adhesive surface
- EMC-compliant
Norm references / Approvals
- UL AWM Style 21098
- CSA AWM IA/B; IIA/B FT 1
- UL File No. E63634
- For use in power chains: Please comply with assembly guideline Appendix T3
Product Make-up
- Extra-fine wire strand made of bare copper wires (class 6)
- Core insulation: PVC
- Cores twisted in layers in short lay lengths
- Non-woven wrapping
- Tinned-copper braiding
- PVC outer sheath, black (similar RAL 9005)
Classification ETIM 5
- ETIM 5.0 Class-ID: EC000104
- ETIM 5.0 Class-Description: Control cable
Classification ETIM 6
- ETIM 6.0 Class-ID: EC000104
- ETIM 6.0 Class-Description: Control cable
Core identification code
- Black with white numbers acc. to VDE 0293-334
Conductor stranding
- Extra-fine wire acc. to VDE 0295, class 6/ IEC 60228 class 6
Minimum bending radius
- Flexing: up from 7.5 x outer diameter
- Fixed installation: 4 x outer diameter
Nominal voltage
- IEC: U0/U 300/500 V
- UL/CSA: 600 V
Test voltage
- 4000 V
Protective conductor
- G = with GN-YE protective conductor
- X = without protective conductor
Temperature range
- Flexing: -5°C to +70°C (UL: +90°C)
- Fixed installation: -40°C to +70°C
(UL: +90°C)
Bending cycles & operation parameters
- See Selection Table A2-1 in the appendix of our online catalogue