LAPP 1026529 1026529 ÖLFLEX CHAIN 90 P 1G50 LAPP ÖLFLEX CHAIN 90 P 1G50 View larger
Images are for illustrative purposes only. Please refer to data sheet for details

1026529 ÖLFLEX CHAIN 90 P 1G50 LAPP ÖLFLEX CHAIN 90 P 1G50

1026529

1026529

ÖLFLEX CHAIN 90 P 1G50

LAPP

1 m.

ÖLFLEX CHAIN 90 P 1G50 ÖLFLEX® CHAIN 90 P

Cables > Power cable 1 kV, for moving application
ÖLFLEX FD cabling

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Engineered as a Lapp 1026529 low voltage power cable, this item provides robust electrical distribution in heavy-duty commercial setups. Power lines route electricity from distribution boards to motors, drives, and heavy machinery safely and efficiently. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • USA: UL AWM Style 11624, VW-1 Canada: cUL AWM I/II A, FT1
  • For use in power chains: Please comply with assembly guideline Appendix T3
  • Core insulation: TPE compound
  • Flexing: up from 7.5 x outer diameter
  • Fixed installation: 3 x outer diameter
  • IEC: U 0 /U 600/1000 V
  • UL & CSA: 1000 V
  • Flexing: -35°C to +80°C
  • Fixed installation: -50°C to +80°C
  • ETIM 5.0 Class-ID: EC000057
  • ETIM 5.0 Class-Description: Low voltage power cable
  • ETIM 6.0 Class-ID: EC000057
  • ETIM 6.0 Class-Description: Low voltage power cable

More info

▲

ÖLFLEX® CHAIN 90 P - Oil resistant power cable for harsh conditions in power chains with UL/cUL AWM certification.

  • Extended Line Performance - Long travel lengths or high acceleration
  • Allrounder for indoor and outdoor use
  • Improved characteristics in the event of a fire

Benefits

  • Allows much faster speed and accelerations which increases the economic efficiency of the machines
  • Multi-standard certification reduces part varieties and saves costs
  • Increased durability under harsh conditions thanks to robust PUR outer sheath
  • Resistant to contact with many mineral oil-based lubricants, diluted acids, aqueous alkaline solutions and other chemical media
  • Wide temperature range for applications in harsh climatic environments
  • Longer cable installation lengths thanks to low mutual capacitance cable design

Application range

  • In power chains or moving machine parts
  • For internal wiring of electric and electronic equipment in switch cabinets
  • Specially designed for power circuits of servomotors driven by frequency converters
  • This cable can substitute multi-core power cables where space requirements or minimum bending radii cause problems
  • Test systems in the automotive industry, vehicles and stationary fuel cell systems
  • For indoor and outdoor use

Product features

  • Flammability:
    - Halogen-free acc. to VDE 0472-815
    - Flame retardant acc. to IEC 60332-1-2 or
    UL/cUL VW-1, FT1
    - No flame propagation acc. to
    IEC 60332-3-24 Cat. C or /-25 Cat. D
  • Good weather, UV and oil resistance
  • Abrasion and notch-resistant
  • Flexible at low temperatures
  • Low-capacitance design

Norm references / Approvals

  • DNV GL approved
  • UL File No. E63634
  • USA: UL AWM Style 11624, VW-1
    Canada: cUL AWM I/II A, FT1
  • For use in power chains: Please comply with assembly guideline Appendix T3

Product Make-up

  • Extra-fine wire strand made of bare copper wires (class 6)
  • Core insulation: TPE compound
  • PUR outer sheath, black (similar RAL 9005)

Classification ETIM 5

  • ETIM 5.0 Class-ID: EC000057
  • ETIM 5.0 Class-Description: Low voltage power cable

Classification ETIM 6

  • ETIM 6.0 Class-ID: EC000057
  • ETIM 6.0 Class-Description: Low voltage power cable

Core identification code

  • Black or green-yellow, other colours available on request

Conductor stranding

  • Extra-fine wire according to VDE 0295, class 6/IEC 60228 class 6

Torsion movement in WTG

  • TW-0 & TW-2, refer to Appendix T0

Minimum bending radius

  • Flexing: up from 7.5 x outer diameter
  • Fixed installation: 3 x outer diameter

Nominal voltage

  • IEC: U0/U 600/1000 V
  • UL & CSA: 1000 V

Test voltage

  • 4000 V

Temperature range

  • Flexing: -35°C to +80°C
  • Fixed installation: -50°C to +80°C

Bending cycles & operation parameters

  • See Selection Table A2-1 in the appendix of our online catalogue

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.