1023279 ÖLFLEX SERVO FD 7DSL 4G2,5+(2x1)+(2x22A) LAPP ÖLFLEX SERVO FD 7DSL 4G2,5+(2x1)+(2x22A)
1023279
1023279
ÖLFLEX SERVO FD 7DSL 4G2,5+(2x1)+(2x22A)
LAPP
1 m.
Cables > Power cable 1 kV, for moving application
ÖLFLEX-SERVO cabling
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Lapp 1023279 control cable is configured for continuous motion applications requiring combined power, signal, and digital feedback routing in cable carriers. Hybrid continuous-flex cables ensure uninterrupted signal transmission in high-speed industrial machinery. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Maximum DSL transmission length: 100m
- Flammability: UL/CSA: VW-1, FT1 IEC/EN: 60332-1-2
- For use in power chains: Please comply with assembly guideline Appendix T3
- Core insulation: polypropylene (PP)
- Power cores: black with marking U/L1/C/L+; V/L2; W/L3/D /L-; GN/YE protective conductor
- Signal pair: white, blue Control pair (optional): black with white numbers 5 + 6
- DSL data pair: 19-wired
- Flexing: up from 7.5 x outer diameter
- Fixed installation: 5 x outer diameter
- Power and control: IEC: U0/U: 600/1000 V UL: 1000 V Signal pair: 300 V
- Power and control: 4 kV Data pair: 1kV
- Flexing: -40°C to +90°C (UL: +80°C)
- Fixed installation: -50°C to +90°C (UL: +80°C)
- ETIM 5.0 Class-ID: EC000104
- ETIM 5.0 Class-Description: Control cable
- ETIM 6.0 Class-ID: EC000104
More info
▲ÖLFLEX® SERVO FD 7DSL - hybrid cable for permanently moved power chain applications, UL/cUL AWM.
- One cable solution for servo drives
- Suitable for Hiperface DSL® and SCS open link interfaces
- Extended Line Performance - Long travel lengths or high acceleration
Benefits
- Allows much faster speed and accelerations which increases the economic efficiency of the machines
- Only one connection line between drive and motor-feedback system. Instead of the encoder cable a specific integrated data pair takes over the signalling.
- Less cables and reduced connection costs
- Space and weight savings thanks to hybrid cable design
- Increased durability under harsh conditions thanks to robust PUR outer sheath
- Resistant to contact with many mineral oil-based lubricants, diluted acids, aqueous alkaline solutions and other chemical media
Application range
- Power drive systems in automation engineering
- Connecting cable between servo controller and motor
- In power chains or moving machine parts
- For use in assembling & pick-and-place machinery
- Particularly in wet areas of machine tools and transfer lines
Product features
- Maximum DSL transmission length: 100m
- Flammability:
UL/CSA: VW-1, FT1
IEC/EN: 60332-1-2 - Halogen-free materials
- Low-capacitance design
- Oil-resistant
Norm references / Approvals
- UL AWM Style 21223
cRU AWM I/II A/B FT1 - UL File No. E63634
- For use in power chains: Please comply with assembly guideline Appendix T3
Product Make-up
- Extra-fine-wire, bare copper conductor (power cores and control pair) and 19-wire, tinned copper conductor (data pair)
- Core insulation: polypropylene (PP)
- Individual design depending on the item: power cores without or with one screened control pair and one DSL data pair twisted together
- Non-woven wrapping
- Tinned-copper braiding
- PUR outer sheath, orange (RAL 2003)
Classification ETIM 5
- ETIM 5.0 Class-ID: EC000104
- ETIM 5.0 Class-Description: Control cable
Classification ETIM 6
- ETIM 6.0 Class-ID: EC000104
- ETIM 6.0 Class-Description: Control cable
Core identification code
- Power cores: black with marking U/L1/C/L+; V/L2; W/L3/D /L-; GN/YE protective conductor
- Signal pair: white, blue
Control pair (optional): black with white numbers 5 + 6
Conductor stranding
- Extra-fine wire according to VDE 0295, class 6/IEC 60228 class 6
- DSL data pair: 19-wired
Minimum bending radius
- Flexing: up from 7.5 x outer diameter
- Fixed installation: 5 x outer diameter
Nominal voltage
- Power and control:
IEC: U0/U: 600/1000 V
UL: 1000 V
Signal pair: 300 V
Test voltage
- Power and control: 4 kV
Data pair: 1kV
Protective conductor
- G = with GN-YE protective conductor
Temperature range
- Flexing: -40°C to +90°C
(UL: +80°C) - Fixed installation: -50°C to +90°C
(UL: +80°C)
Bending cycles & operation parameters
- See Selection Table A2-1 in the appendix of our online catalogue