View larger
1023239 ÖLFLEX CHAIN 896P 5G2,5 LAPP ÖLFLEX CHAIN 896P 5G2,5
1023239
1023239
ÖLFLEX CHAIN 896P 5G2,5
LAPP
1 m.
Cables > Power cable 1 kV, for moving application
ÖLFLEX FD cabling
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Lapp 1023239 ÖLFLEX CHAIN 896P 5G2,5 control cable delivers reliable power and control signaling inside continuous-flex energy chains for automated robotics and machinery. Its polyurethane outer jacket resists abrasion and mechanical wear during high-speed movements.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Flammability: UL/CSA: VW-1, FT1 IEC/EN: 60332-1-2
- For use in power chains: Please comply with assembly guideline Appendix T3
- Core insulation: polypropylene (PP)
- Flexing: up from 7.5 x outer diameter (up to 16mm²) up from 10 x outer diameter (from 25mm²)
- Fixed installation: 4 x outer diameter
- IEC U0/U: 600/1000 V
- UL & CSA: 1000 V
- Flexing: -40°C to +90°C (UL/CSA: +80°C)
- Fixed installation: -50°C to +90°C (UL/CSA: +80°C)
- ETIM 5.0 Class-ID: EC000104
- ETIM 5.0 Class-Description: Control cable
- ETIM 6.0 Class-ID: EC000104
- ETIM 6.0 Class-Description: Control cable
More info
▲ÖLFLEX® CHAIN 896 P - Power cable for use in drag chains in harsh environmental conditions with UL/CSA AWM certification
- Extended Line Performance - Long travel lengths or high acceleration
- High oil resistance
- Rated voltage 0,6/1 kV
Benefits
- Allows much faster speed and accelerations which increases the economic efficiency of the machines
- Multi-standard certification reduces part varieties and saves costs
- Increased durability under harsh conditions thanks to robust PUR outer sheath
- Resistant to contact with many mineral oil-based lubricants, diluted acids, aqueous alkaline solutions and other chemical media
- Longer cable installation lengths thanks to low mutual capacitance cable design
- Wide temperature range for applications in harsh climatic environments
Application range
- In power chains or moving machine parts
- Applications in automation engineering
- Power circuits in industrial machines
- For use in assembling & pick-and-place machinery
- Particularly in wet areas of machine tools and transfer lines
- For indoor and outdoor use
Product features
- Flammability:
UL/CSA: VW-1, FT1
IEC/EN: 60332-1-2 - Halogen-free materials
- Resistant to oil and drilling fluids according to IEC 61892-4, Appendix D
- Low-capacitance design
- Flexible down to -40°C
Norm references / Approvals
- VDE - reg - no. 8661
UL AWM Style 20234
cULus AWM I/II A/B, 1000V 80° FT1
CSA AWM I/II A, 1000V 80° FT1 - UL File No. E63634
- For use in power chains: Please comply with assembly guideline Appendix T3
Product Make-up
- Extra-fine wire strand made of bare copper wires (class 6)
- Core insulation: polypropylene (PP)
- Non-woven wrapping
- PUR outer sheath, black (similar RAL 9005)
Classification ETIM 5
- ETIM 5.0 Class-ID: EC000104
- ETIM 5.0 Class-Description: Control cable
Classification ETIM 6
- ETIM 6.0 Class-ID: EC000104
- ETIM 6.0 Class-Description: Control cable
Core identification code
- Black with white numbers acc. to VDE 0293-334
Conductor stranding
- Extra-fine wire according to VDE 0295, class 6/IEC 60228 class 6
Minimum bending radius
- Flexing:
up from 7.5 x outer diameter (up to 16mm²)
up from 10 x outer diameter (from 25mm²) - Fixed installation: 4 x outer diameter
Nominal voltage
- IEC U0/U: 600/1000 V
- UL & CSA: 1000 V
Test voltage
- 4000 V
Protective conductor
- G = with GN-YE protective conductor
- X = without protective conductor
Temperature range
- Flexing: -40°C to +90°C
(UL/CSA: +80°C) - Fixed installation: -50°C to +90°C
(UL/CSA: +80°C)
Bending cycles & operation parameters
- See Selection Table A2-1 in the appendix of our online catalogue