1 m.
Cables > Power cable 1 kV, for moving application
ÖLFLEX-SERVO cabling
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Control cable designated as 1020022 ÖLFLEX SERVO 719 CY 4G6+(2x1,5) from Lapp is built for connecting automated industrial drive systems and servo motors. These cables run signal and power lines within automated assembly lines, robotic cells, and motion control architecture. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Flammability: UL/CSA: VW-1, FT1 IEC/EN: 60332-1-2
- USA: UL AWM Style 2570 Canada: cUL AWM Style I/II A/B FT1
- Core insulation: polypropylene (PP)
- Power cores: black with marking U/L1/C/L+; V/L2; W/L3/D /L-; GN/YE protective conductor
- Occasional flexing: 15 x outer diameter
- Fixed installation: 6 x outer diameter
- Power cores and control cores: IEC U0/U: 600/1000 V; UL & CSA: 1000 V
- Core/Core: 4 kV
- Core/Screen: 4 kV
- Occasional flexing: -5°C to +70°C (UL: +80°C) Fixed installation: -40°C to +80°C
- ETIM 5.0 Class-ID: EC000104
- ETIM 5.0 Class-Description: Control cable
- ETIM 6.0 Class-ID: EC000104
- ETIM 6.0 Class-Description: Control cable
More info
▲ÖLFLEX® SERVO 719 CY - Screened, low capacitive servo cable for fixed installation or occasional flexing with UL/cUL AWM certification
- Successor of ÖLFLEX® SERVO 700 CY and ÖLFLEX® SERVO 709 CY
- Low-capacitance design
- Product range extension
Benefits
- Suitable for use with servomotor product lines from leading drive manufacturers
- Longer cable installation lengths thanks to low mutual capacitance cable design
- Multi-standard certification reduces part varieties and saves costs
- Space and weight-saving installations due to small cable diameters
- Copper braiding screens the cable against
electromagnetic interference
Application range
- Connecting cable between servo controller and motor
- For static and occasionally flexible use
- Plant engineering
- Industrial machinery and machine tools
- Printing machines
Product features
- Low capacitance
- Flammability:
UL/CSA: VW-1, FT1
IEC/EN: 60332-1-2 - Oil-resistant
- EMC-compliant
Norm references / Approvals
- USA: UL AWM Style 2570
Canada: cUL AWM Style I/II A/B FT1 - UL File No. E63634
Product Make-up
- Fine-wire, bare copper conductor
- Core insulation: polypropylene (PP)
- Individual design depending on the item:
Power cores without or with one or two individually shielded control core pairs twisted together in short lay lengths;
Power cores with control core triplet twisted together in short lay lengths - Tinned copper screen braiding
- PVC outer sheath, orange (RAL 2003)
Classification ETIM 5
- ETIM 5.0 Class-ID: EC000104
- ETIM 5.0 Class-Description: Control cable
Classification ETIM 6
- ETIM 6.0 Class-ID: EC000104
- ETIM 6.0 Class-Description: Control cable
Core identification code
- Power cores: black with marking U/L1/C/L+; V/L2; W/L3/D /L-; GN/YE protective conductor
- Single-paired versions: individual design depending on the item black; white or brown; white
Double-paired versions: black with white numbers 5; 6; 7; 8
0.34 mm² pairs: WH/BN/GN/YE
Triplet: black with white numbers 1; 2; 3
Conductor stranding
- Fine wire according to VDE 0295 Class 5/ IEC 60228 Class 5
Minimum bending radius
- Occasional flexing: 15 x outer diameter
- Fixed installation: 6 x outer diameter
Nominal voltage
- Power cores and control cores:
IEC U0/U: 600/1000 V - UL & CSA: 1000 V
Test voltage
- Core/Core: 4 kV
- Core/Screen: 4 kV
Protective conductor
- G = with GN-YE protective conductor
Temperature range
- Occasional flexing:
-5°C to +70°C (UL: +80°C)
Fixed installation: -40°C to +80°C