View larger
0162045 NiCr/Ni KCA 2x0,75 IEC PVC-PVC LAPP Extension and compensating cables, PVC, silicone, FEP or glass f..
0162045
0162045
NiCr/Ni KCA 2x0,75 IEC PVC-PVC
LAPP
100 m.
Cables > Thermocouple cable
ÖLFLEX HEAT Temperature measurement cables
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Applied in industrial settings where thermal accuracy is paramount, this Lapp thermocouple cable connects temperature probes to local control panels. Compensating conductors safeguard the measurement circuit against ambient thermal gradients that could otherwise skew sensitive readings. Exact pricing, availability and lead time are confirmed per enquiry through an RFQ.
- New: thermocouple cable type K
- Conductor materials (alloys): Fe/CuNi (LX, JX) Conductor alloys are identical to thermocouple alloys
- PtRh/Pt (RCB, SCB): Compensating alloys (for RCB, SCB: Cu/CuNi) are not identical to thermocouple alloys
- Design, for example PVC-PVC-S-PVC: - PVC core insulation - PVC inner sheath - Steel wire braiding - PVC outer sheath
- Without metal braiding: 12 x cable diameter
- With metal braiding: 15 x cable diameter
- ETIM 5.0 Class-ID: EC000838
- ETIM 5.0 Class-Description: Thermocouple cable
- ETIM 6.0 Class-ID: EC000838
- ETIM 6.0 Class-Description: Thermocouple cable
More info
▲Extension and compensating cables, single-paired version - suitable for use in temperature measurement and manufacturing process control
- Available in many different designs
- New: thermocouple cable type K
Norm references / Approvals
- Space-saving and flexible
- For more detailed information, see appendix T8 and data sheets
Application range
- Allows temperature measurement even in places where non-contact temperature measurement is not possible or reasonable
- The thermocouple is used to measure temperature as a part of monitoring the manufacturing process, thus the sheath material should be selected with reference to the maximum ambient temperature at its junction.
- Conductor materials (alloys):
Fe/CuNi (LX, JX)
Conductor alloys are identical to thermocouple alloys - NiCr/Ni (K, KX, KCA)
K and KX version - conductor alloys are identical to thermocouple alloys
KCA version: compensating alloys (for KCA: Fe/CuNi), not identical to thermocouple alloys - PtRh/Pt (RCB, SCB)
Compensating alloys (for RCB, SCB: Cu/CuNi) are not identical to thermocouple alloys
Norm references / Approvals
- Colour identity code DIN 43710 Negative conductor and outer sheath:Fe/CuNi: blueNiCr/Ni: greenPtRh/Pt: whitePositive conductor: always redIEC 60 584 Positive conductor and outer sheath:Fe/CuNi: blackNiCr/Ni: greenPtRh/Pt: orangeNegative conductor: always white
Product Make-up
- Design abbreviations:
PVC: Polyvinylchloride
SIL: Silicone rubber
GL: Glass fibre
FEP: Fluorinated ethylene propylene
EGL: E-Glass fibre
C: Copper braiding screen
ST: Aluminium foil screen
S: Steel wire braiding - Design, for example PVC-PVC-S-PVC:
- PVC core insulation
- PVC inner sheath
- Steel wire braiding
- PVC outer sheath - Examples shown (top to bottom):
Fe/CuNi DIN 2 x 1.5 PVC
NiCr/Ni IEC 2 x 1.5 GL-GL
PtRh/Pt IEC 2 x 1.5 GL-GL-S
NiCr/Ni DIN 2 x 1.5 SIL-GL
NiCr/Ni DIN 2 x 1.5 PVC-PVC
PtRh/Pt DIN 2 x 1.5 SIL-SIL
Fe/CuNi IEC 2 x 1.5 SIL-SIL-S
NiCr/Ni IEC 2 x 1.5 SIL
PtRh/Pt IEC 2 x 1.5 SIL-GL-S
Fe/CuNi IEC 2 x 0.22 PVC-PVC-C-PVC
NiCr/Ni IEC 2 x 1.5 PVC-ST-PVC
Fe/CuNi DIN 2 x 1.5 PVC-PVC-S-PVC
Classification ETIM 5
- ETIM 5.0 Class-ID: EC000838
- ETIM 5.0 Class-Description: Thermocouple cable
Classification ETIM 6
- ETIM 6.0 Class-ID: EC000838
- ETIM 6.0 Class-Description: Thermocouple cable
Based on
- Limiting deviation in accordance with DIN and IEC in accordance with class 2
Conductor stranding
- 1.5 mm²: approx. 48 x 0.20 mm
0.75 mm²: approx. 24 x 0.20 mm
0.5 mm²: approx. 16 x 0.20 mm
0.22 mm²: approx. 7 x 0.20 mm
Minimum bending radius
- Without metal braiding:
12 x cable diameter - With metal braiding:
15 x cable diameter
Temperature range
- (referring to insulation and sheath material)
PVC: -5°C to +80°C
Silicone: -25°C to +180°C
Glass fibre: -25°C to +200°C
FEP: -100°C to +205°C