View larger
0100104 ÖLFLEX HEAT 260 SC 22/19 AWG RD LAPP ÖLFLEX HEAT 260 SC 22/19 AWG RD
0100104
0100104
ÖLFLEX HEAT 260 SC 22/19 AWG RD
LAPP
100 m.
Cables > Power cable less 1 kV, for permanent installation
ÖLFLEX HEAT Temperature measurement cables
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Lapp 0100104 single core cable offers exceptional thermal endurance for specialized wiring tasks in extreme environments such as furnaces, aerospace equipment, and heavy industrial kilns. High-temperature single core hookup wire is typically installed where standard insulation would quickly degrade from intense localized heat. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Flame retardance rating (UL): FT2 (Horizontal flame test)
- AWG conductor sizes: 7, 19 or 37 wires
- Fixed installation: 4 x outer diameter
- U0/U: 300/500 V
- Fixed installation: -190°C to +260°C
- UL/CSA: up to +200°C
- ETIM 5.0 Class-ID: EC000993
- ETIM 5.0 Class-Description: Single core cable
- ETIM 6.0 Class-ID: EC000993
- ETIM 6.0 Class-Description: Single core cable
More info
▲ÖLFLEX® HEAT 260 SC - PTFE single core, robust, chemical resistant and space-saving, for use in machine and plant construction at temperatures: -190°C to +260°C
- Excellent chemical, thermal and
electrical performance - Space and weight-saving
- UL AWM Style 11486 (28-12 AWG)
Benefits
- Small outer diameters for maximum saving of space and weight
- Resistant to contact with mostly all highly aggressive chemical media
- Stress crack resistant to frequent ambient temperature fluctuations
Application range
- For use in environments with very high operating temperatures, heavy usage of chemical agents or confined spaces
- Typical fields of application
- Aerospace engineering
- High-frequency engineering
- Control cabinets with high heat
generation
- Measuring instruments
- Furnaces and brickworks
- Heating equipment and kitchen
appliances
- Electric motor building
- Installations in the chemical industry
Product features
- Flame retardance rating (UL): FT2 (Horizontal flame test)
- Flame-retardant according to IEC 60332-1-2 & CSA FT1
- ÖLFLEX® HEAT 260 made of PTFE
- Outstanding resistance against acids,
alkalis, solvents, lacquers, petrol, oils and
many other chemical media
- Difficult to inflame
- High dielectric strength and high abrasion
resistance
- Low water absorption
- Resistant to microbes
- Adhesion-free insulation materials
- Weather and ozone resistant
- Hydrophobic and dirt-repellent
- High elongation and tear resistance
- Resists contact with liquid nitrogen
- Resistant against hydraulic fluids - Silver plated copper is characterized by good surface conductivity (skin effect) and good solderability
Norm references / Approvals
- 28-12 AWG: UL AWM Style 11486 according to UL 758 (File No E63634) & cRU AWM I A/B according to CSA C22.2 No 210 (File No E63634)
Product Make-up
- Silver-plated AWG copper conductor
- PTFE core insulation
- PTFE = Polytetrafluoroethylene
Classification ETIM 5
- ETIM 5.0 Class-ID: EC000993
- ETIM 5.0 Class-Description: Single core cable
Classification ETIM 6
- ETIM 6.0 Class-ID: EC000993
- ETIM 6.0 Class-Description: Single core cable
Conductor stranding
- AWG conductor sizes: 7, 19 or 37 wires
Minimum bending radius
- Fixed installation: 4 x outer diameter
Nominal voltage
- U0/U: 300/500 V
Test voltage
- 3400 V
Temperature range
- Fixed installation: -190°C to +260°C
- UL/CSA: up to +200°C