View larger
Images are for illustrative purposes only. Please refer to data sheet for details
0041077 ÖLFLEX CRANE CF 12G1,5 LAPP ÖLFLEX CRANE CF 12G1,5
0041077
0041077
ÖLFLEX CRANE CF 12G1,5
LAPP
1 m.
ÖLFLEX CRANE CF 12G1,5
ÖLFLEX® CRANE CF
Cables > Power cable less 1 kV, for moving application
Control cables for special applications
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteMore info
▲ÖLFLEX® CRANE CF - Flat cable for outdoor use and crane applications/conveyour technology. Screened power and control rubber cable, U0/U:300/500V
- For outdoor cable trolley application
- EMC-compliant
Benefits
- Weather-resistant for harsh environmental conditions
- Flat cables need less space than round cables
- Smaller bending radii is possible
- Copper braiding screens the cable against
electromagnetic interference
Application range
- In crane systems on building sites and shipyards for fixed installation, or for flexible use in
cable trolley systems - Sewage treatment plants, steelworks and high rack facilities
- The application profiles for ÖLFLEX® CRANE and ÖLFLEX® LIFT cables can be found in the appendix, selection table A3
- As a lift control cable: max. 50 m suspension length
Product features
- Flame-retardant according IEC 60332-1-2
Norm references / Approvals
- Based on VDE 0250-809 (NGFLGÖU)
Product Make-up
- Conductors: Finely stranded bare copper
- Core insulation: rubber compound
- Individual core screening consist of
- plastic foil wrapping
- tin-plated copper braiding
- plastic foil wrapping - Outer sheath: special rubber compound
Classification ETIM 5
- ETIM 5.0 Class-ID: EC000825
- ETIM 5.0 Class-Description: Flat cable
Classification ETIM 6
- ETIM 6.0 Class-ID: EC000825
- ETIM 6.0 Class-Description: Flat cable
Core identification code
- Up to 5 cores: colour-coded according to VDE 0293-308, refer to Appendix T9
- From 6 cores: black with white numbers
Conductor stranding
- Copper conductor according to VDE 0295/IEC 60228
up to 25 mm²: extra-fine wire, class 6
from 35 mm²: fine wire, class 5
Minimum bending radius
- Flexible use: 10 x cable thickness
- Fixed installation: 4 x cable thickness
Nominal voltage
- U0/U: 300/500 V
Test voltage
- 2000 V
Protective conductor
- G = with GN-YE protective conductor
- X = without protective conductor
Temperature range
- Flexible use: -25°C to +90°C
- Fixed installation: -40°C to +90°C