View larger
00350213 ÖLFLEX CLASSIC 100 CY 4G10 LAPP ÖLFLEX CLASSIC 100 CY 450/750V 4G10
00350213
00350213
ÖLFLEX CLASSIC 100 CY 4G10
LAPP
1 m.
Cables > Power cable less 1 kV, for moving application
ÖLFLEX PVC, coloured cores, screened
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Constructed as an electromagnetic-shielded control cable, the Lapp 00350213 ÖLFLEX CLASSIC 100 CY 4G10 links automated industrial machinery while blocking external electrical interference. Braided copper shielding protects internal conductors from signal disruption in electrically noisy factory environments. Pricing, stock status, and lead times are confirmed per enquiry through an RFQ.
- CPR: Article number choice under www.lappkabel.com/cpr
- For nominal voltage U0/U: 300/500V and conductor cross-sections below 1,5mm² see ÖLFLEX® CLASSIC 100 CY 300/500V
- Up to 5 cores: colour-coded according to VDE 0293-308, refer to Appendix T9
- From 6 cores: ÖLFLEX® colour code, refer to Appendix T7
- Occasional flexing: 20 x outer diameter
- Fixed installation: 6 x outer diameter
- U0/U: 450/750 VAC In protected and fixed installations: U0/U: 600/1000 V
- Occasional flexing: -5°C to +70°C
- Fixed installation: -40°C to +80°C
- ETIM 5.0 Class-ID: EC001578
- ETIM 5.0 Class-Description: Flexible cable
- ETIM 6.0 Class-ID: EC001578
- ETIM 6.0 Class-Description: Flexible cable
More info
▲ÖLFLEX® CLASSIC 100 CY 450/750V - flexible PVC cable, colour coded and screened, power and control cable for various applications
- CPR: Article number choice under www.lappkabel.com/cpr
- EMC-compliant
- For nominal voltage U0/U: 300/500V and conductor cross-sections below 1,5mm² see ÖLFLEX® CLASSIC 100 CY 300/500V
Benefits
- High electrical performance due to 4 kV test voltage
- Shielding against electromagnetic fields
Application range
- Plant engineering
Industrial machinery
Heating and air-conditioning systems - Conveyor and transport systems
- Servo drives
- In EMC-sensitive environments
(electromagnetic compatibility)
Product features
- Flame-retardant according IEC 60332-1-2
- Good chemical resistance, see catalogue appendix T1
- High degree of screening
low transfer impedance
(max. 250 Ω/km at 30 MHz)
Norm references / Approvals
- Based on EN 50525-2-51
- Based on EN 50525-2-11 and EN 50525-2-31
Product Make-up
- Fine-wire strand made of bare copper wires
- PVC insulation LAPP P8/1
- Cores twisted in layers
- PVC inner sheath, grey
- Tinned-copper braiding
- PVC outer sheath, transparent
Classification ETIM 5
- ETIM 5.0 Class-ID: EC001578
- ETIM 5.0 Class-Description: Flexible cable
Classification ETIM 6
- ETIM 6.0 Class-ID: EC001578
- ETIM 6.0 Class-Description: Flexible cable
Core identification code
- Up to 5 cores: colour-coded according to VDE 0293-308, refer to Appendix T9
- From 6 cores: ÖLFLEX® colour code, refer to Appendix T7
Conductor stranding
- Fine wire according to VDE 0295,
class 5/IEC 60228 class 5
Minimum bending radius
- Occasional flexing: 20 x outer diameter
- Fixed installation: 6 x outer diameter
Nominal voltage
- U0/U: 450/750 VAC
In protected and fixed installations:
U0/U: 600/1000 V
Test voltage
- 4000 V
Protective conductor
- G = with GN-YE protective conductor
- X = without protective conductor
Temperature range
- Occasional flexing: -5°C to +70°C
- Fixed installation: -40°C to +80°C