LAPP 0032471 0032471 RD-Y(ST)Y 4x2x0,5 GY LAPP RD-Y(ST)Y 4x2x0,5 GY View larger
Images are for illustrative purposes only. Please refer to data sheet for details

0032471 RD-Y(ST)Y 4x2x0,5 GY LAPP RD-Y(ST)Y 4x2x0,5 GY

0032471

0032471

RD-Y(ST)Y 4x2x0,5 GY

LAPP

100 m.

RD-Y(ST)Y 4x2x0,5 GY RD-Y(ST)Y

Cables > Data and communication cable
UNITRONIC low frequency

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

The Lapp 0032471 RD-Y(ST)Y 4x2x0,5 GY is an instrumentation and computer cable utilized in process automation for transmitting measurement data and control signals. Its layered shield helps maintain signal integrity in industrial measurement loops. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.

  • Outer sheath colour: grey or blue for intrinsically safe systems
  • Outer sheath colour: grey
  • Pair no. 1: a-conductor: blue b-conductor: red Pair no. 2: a-conductor: grey b-conductor: yellow
  • Pair no. 3: a-core: green b-core brown Pair no. 4: a-core: white b-core black
  • At 800 Hz: ≤ 100 nF/km The values may be exceeded by 20 % on cables with up to 4 double cores.
  • (loop): ≤ 73.6 Ohm/km
  • At 1 kHz: approx. 1.2 dB/km
  • At 10 kHz: approx. 2.8 dB/km
  • Occasional flexing: 15 x outer diameter
  • Fixed installation: 7.5 x outer diameter
  • At 10 kHz and 500 m cable length: min. 60 dB
  • C/C: 2000 V
  • C/S: 2000 V
  • At 1 kHz: approx. 370 ohm
  • At 10 kHz: approx. 130 ohm
  • Occasional flexing: -5°C to +50°C

More info

▲

RD-Y(ST)Y: PVC Process control data cable for, e.g., control stations/ units and monitoring systems, Maxi TERMI-POINT®, Paired stranding, Static screen foil

Benefits

  • Decoupling of circuits by means of twisted-pair (TP) design (crosstalk effects)

Application range

  • RD-Y(ST)Y is used as a data transmission cable for applications such as monitoring systems and control units
  • Measurement, control and regulation technology and also in control rooms of power plants and industrial facilities.
  • Suitable for transmission of analog and digital signals up to a frequency of about 10 kHz
  • Designed for fixed installations in enclosed rooms.

Product features

  • Outer sheath colour: grey or
    blue for intrinsically safe systems
  • Variant with 2 double cores twisted as star quad
  • Flame retardant acc. to IEC 60332-1-2

Norm references / Approvals

  • Based on DIN VDE 0815

Product Make-up

  • 7-wire bare stranded copper conductor,
    core insulation made of PVC
  • Cores twisted into pairs,
    4 pairs twisted into a bundle,
    bundles in layers,
    bundles labelled using numbered foil
  • Aluminium-laminated plastic foil static screen with tinned drain wire
  • Outer sheath made of PVC
  • Outer sheath colour: grey

Classification ETIM 5

  • ETIM 5.0 Class-ID: EC000104
  • ETIM 5.0 Class-Description: Control cable

Classification ETIM 6

  • ETIM 6.0 Class-ID: EC000104
  • ETIM 6.0 Class-Description: Control cable

Core identification code

  • Pair no. 1: a-conductor: blue
    b-conductor: red
    Pair no. 2: a-conductor: grey
    b-conductor: yellow
  • Pair no. 3: a-core: green
    b-core brown
    Pair no. 4: a-core: white
    b-core black

Mutual capacitance

  • At 800 Hz: ≤ 100 nF/km
    The values may be exceeded by 20 % on cables with up to 4 double cores.

Conductor resistance

  • (loop): ≤ 73.6 Ohm/km

Cable attenuation/attenuation

  • At 1 kHz: approx. 1.2 dB/km
  • At 10 kHz: approx. 2.8 dB/km

Minimum bending radius

  • Occasional flexing: 15 x outer diameter
  • Fixed installation: 7.5 x outer diameter

Short-range crosstalk attenuation

  • At 10 kHz and 500 m cable length:
    min. 60 dB

Test voltage

  • C/C: 2000 V
  • C/S: 2000 V

Characteristic impedance

  • At 1 kHz: approx. 370 ohm
  • At 10 kHz: approx. 130 ohm

Temperature range

  • Occasional flexing: -5°C to +50°C
  • Fixed installation: -40°C to +80°C

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.