LAPP 0032401 0032401 UNITRONIC RE-2Y(ST)YV 2X2X0,5 BU LAPP UNITRONIC RE-2Y(ST)YV 2X2X0,5 BU View larger
Images are for illustrative purposes only. Please refer to data sheet for details

0032401 UNITRONIC RE-2Y(ST)YV 2X2X0,5 BU LAPP UNITRONIC RE-2Y(ST)YV 2X2X0,5 BU

0032401

0032401

UNITRONIC RE-2Y(ST)YV 2X2X0,5 BU

LAPP

100 m.

UNITRONIC RE-2Y(ST)YV 2X2X0,5 BU UNITRONIC

Cables > Data and communication cable
UNITRONIC low frequency

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Built for intrinsic safety applications, the Lapp 0032401 UNITRONIC RE-2Y(ST)YV 2X2X0,5 BU instrumentation cable connects sensitive measurement devices in hazardous process areas. Instrumentation lines deliver stable, noise-free signals from industrial sensors to monitoring equipment.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Outer sheath colour: black for outdoor applications or blue for intrinsically safe systems
  • Outer sheath colour: black (RAL 9005) or blue (RAL 5015)
  • a-core: black
  • b-core: white with consecutive numbers: 1-1, 2-2, 3-3, 4-4 etc.
  • Three-way version: black, white, red
  • (guideline values at 800 Hz): C/C: 0.5 mm²: max. 75 nF/km
  • (guideline values at 800 Hz): C/C: 1.3 mm²: max. 100 nF/km
  • 0.5 mm²: max. 39.2 ohm/km
  • 1.3 mm²: max. 14.3 ohm/km
  • Occasional flexing: 15 x outer diameter
  • Fixed installation: 7.5 x outer diameter
  • At 60 kHz: min. 0.88 dB/km
  • Core/core: 2000 V
  • Core/screen: 1000 V
  • Occasional flexing: -5°C to +50°C
  • Fixed installation: -40°C to +80°C
  • ETIM 5.0 Class-ID: EC000104

More info

▲

RE-2Y(ST)Yv: PVC computer data cables, 7-wire Cu conductor, Low capacitance, Paired stranding, Screened/ Static Foil, PVC jacket, Black or blue, Flame retardant

CPR: Article number choice under www.lappkabel.com/cpr

Benefits

  • Aluminium-laminated plastic foil static screen with tin-plated drain wire minimises the interference of high frequency, electromagnetic fields
  • Decoupling of circuits by means of
    twisted-pair (TP) design (crosstalk effects)
  • Low capacitance due to polyolefin-based insulation

Application range

  • In measurement and control engineering
  • Electrically intended for use when modern process computers have to process large volumes of data, e.g. high-capacity computer systems in waste incineration plants or sewage treatment plants
  • These cables are suitable for fixed installation in dry or damp rooms and, in case of versions with a black outer sheath, also for outdoor use
  • Thanks to reinforced, nominal/ minimum average wall thickness of the outer sheath of at least 1.8 mm, for applications, where a reinforced outer sheath may turn out to be advantageous.

Product features

  • Outer sheath colour:
    black for outdoor applications or
    blue for intrinsically safe systems
  • Flame-retardant according IEC 60332-1-2

Norm references / Approvals

  • In the style of EN 50288-7

Product Make-up

  • 7-wire bare stranded copper conductor,
    core insulation made of polyethylene (PE),
    cores twisted into pairs,
    pairs stranded in layers
  • Complete stranding contains 1 core for communication (core colour orange);
    the communication core is omitted on single-pair versions
  • Foil wrapping,
    static screening made of aluminium-laminated plastic film with tinned drain wire
  • Reinforced outer sheath made of PVC
  • Outer sheath colour: black (RAL 9005)
    or blue (RAL 5015)

Classification ETIM 5

  • ETIM 5.0 Class-ID: EC000104
  • ETIM 5.0 Class-Description: Control cable

Classification ETIM 6

  • ETIM 6.0 Class-ID: EC000104
  • ETIM 6.0 Class-Description: Control cable

Core identification code

  • a-core: black; b-core: white
    with consecutive numbers:
    1-1, 2-2, 3-3, 4-4 etc.
  • Three-way version: black, white, red

Mutual capacitance

  • (guideline values at 800 Hz):
    C/C: 0.5 mm²: max. 75 nF/km
  • (guideline values at 800 Hz):
    C/C: 1.3 mm²: max. 100 nF/km

Conductor resistance

  • 0.5 mm²: max. 39.2 ohm/km
  • 1.3 mm²: max. 14.3 ohm/km

Minimum bending radius

  • Occasional flexing: 15 x outer diameter
  • Fixed installation: 7.5 x outer diameter

Short-range crosstalk attenuation

  • At 60 kHz: min. 0.88 dB/km

Test voltage

  • Core/core: 2000 V
  • Core/screen: 1000 V

Characteristic impedance

  • approx. 100 ohms

Temperature range

  • Occasional flexing: -5°C to +50°C
  • Fixed installation: -40°C to +80°C

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.