View larger
0015102 ÖLFLEX 150 2X0,75 LAPP ÖLFLEX 150 2X0,75
0015102
0015102
ÖLFLEX 150 2X0,75
LAPP
1 m.
Cables > Power cable less 1 kV, for moving application
ÖLFLEX PVC cable AWM recognized
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Lapp ÖLFLEX 150 2X0,75 harmonized oil-resistant control cable utilized for connecting instrumentation, control equipment, and machine components exposed to lubricating fluids. It guarantees consistent performance in dynamic factory environments. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Oil-resistant according to EN 50363-4-1: TM5
- Harmonised (HAR): H05VV5-F and UL recognized
- Occasional flexing: 12.5 x outer diameter
- Fixed installation: 4 x outer diameter
- HAR U0/U: 300/500 V
- UL/CSA: 600 V
- Occasional flexing: HAR: -5°C to +70°C UL/CSA: +90°C
- Fixed installation: HAR: -40°C to +70°C UL/CSA: +90°C
- ETIM 5.0 Class-ID: EC000104
- ETIM 5.0 Class-Description: Control cable
- ETIM 6.0 Class-ID: EC000104
- ETIM 6.0 Class-Description: Control cable
More info
▲ÖLFLEX® 150 - H05VV5-F harmonised PVC control cable with UL/CSA AWM, oil-resistant, flexible and numbered for various applications, U0/U: 300/500 V
- Oil-resistant according to EN 50363-4-1: TM5
- Harmonised (HAR): H05VV5-F and UL recognized
Benefits
- Wide application range due to multiple certifications
Application range
- Plant engineering
Industrial machinery
Heating and air-conditioning systems - Machine tools
- Mainly used in dry, damp and wet interiors (including water-oil mixtures), but not for outdoor use
- For fixed installation under medium mechanical load conditions, and applications with occasional flexing at free, non-continuously recurring movement without tensile load or compulsory guidance
- Note: for the use of AWM (Appliance Wiring Material) cables in industrial machinery (USA) according to NFPA 79: please see the catalogue appendix table T29
Product features
- Flame-retardant according to IEC 60332-1-2
and UL 1581 §1061 Cable Flame Test - Oil-resistant according to EN 50363-4-1: TM5
Norm references / Approvals
- H05VV5-F (EN 50525-2-51)
- UL AWM Style 21098
CSA AWM I A/B II A/B - Multi-standard cables have conductor strands with nominal sizes in mm² or AWG/kcmil. The master size is mentioned in the table below, while the equivalent size of the other system can be found in the Appendix T16 of this catalogue. For this related secondary size the cross-section of the conductor mostly works out to be greater than the
specified nominal value.
Product Make-up
- Fine-wire strand made of bare copper wires
- PVC core insulation
- Cores twisted in layers
- PVC outer sheath, high oil-resistance, grey (similar to RAL 7001)
Classification ETIM 5
- ETIM 5.0 Class-ID: EC000104
- ETIM 5.0 Class-Description: Control cable
Classification ETIM 6
- ETIM 6.0 Class-ID: EC000104
- ETIM 6.0 Class-Description: Control cable
Core identification code
- Black with white numbers acc. to VDE 0293-334
Conductor stranding
- Fine wire according to VDE 0295,
class 5/IEC 60228 class 5
Minimum bending radius
- Occasional flexing: 12.5 x outer diameter
- Fixed installation: 4 x outer diameter
Nominal voltage
- HAR U0/U: 300/500 V
- UL/CSA: 600 V
Test voltage
- 3000 V
Protective conductor
- G = with GN-YE protective conductor
- X = without protective conductor
Temperature range
- Occasional flexing:
HAR: -5°C to +70°C
UL/CSA: +90°C - Fixed installation:
HAR: -40°C to +70°C
UL/CSA: +90°C