LAPP 00104033 00104033 ÖLFLEX CLASSIC 100 YELLOW 5G1,5 LAPP ÖLFLEX CLASSIC 100 YELLOW 5G1,5 View larger
Images are for illustrative purposes only. Please refer to data sheet for details

00104033 ÖLFLEX CLASSIC 100 YELLOW 5G1,5 LAPP ÖLFLEX CLASSIC 100 YELLOW 5G1,5

00104033

00104033

ÖLFLEX CLASSIC 100 YELLOW 5G1,5

LAPP

1 m.

ÖLFLEX CLASSIC 100 YELLOW 5G1,5 ÖLFLEX® CLASSIC 100 YELLOW

Cables > Power cable less 1 kV, for moving application
ÖLFLEX PVC, colored cores

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

ÖLFLEX® CLASSIC 100 YELLOW - flexible PVC cable, colour coded. Power and control cable with yellow outer sheath for warning purposes, 450/750V, also for YSLY or YY

  • CPR: Article number choice under www.lappkabel.com/cpr
  • For warning purposes

Benefits

  • High electrical performance due to 4 kV test voltage

Application range

  • For electrical circuits that remain 'live' after the main switch has been disconnected
  • Service sockets and illumination circuits
    in electrical switchboards and cabinets
  • Suitable for torsional applications which are typical for the loop in wind turbine generators (WTG)

Product features

  • Flame-retardant according IEC 60332-1-2
  • Good chemical resistance, see catalogue appendix T1

Norm references / Approvals

  • Based on IEC 60227-5 and EN 50525-2-51

Product Make-up

  • Fine-wire strand made of bare copper wires
  • PVC insulation LAPP P8/1
  • Outer sheath: PVC, yellow (similar to RAL 1016)

Classification ETIM 5

  • ETIM 5.0 Class-ID: EC001578
  • ETIM 5.0 Class-Description: Flexible cable

Classification ETIM 6

  • ETIM 6.0 Class-ID: EC001578
  • ETIM 6.0 Class-Description: Flexible cable

Core identification code

  • VDE 0293-308, refer to Appendix T9

Conductor stranding

  • Fine wire according to VDE 0295,
    class 5/IEC 60228 class 5

Torsion movement in WTG

  • TW-0 & TW-1, refer to Appendix T0

Minimum bending radius

  • Occasional flexing: 15 x outer diameter
  • Fixed installation: 4 x outer diameter

Nominal voltage

  • U0/U: 450/750 VAC
    In protected and fixed installations:
    U0/U: 600/1000 V

Test voltage

  • 4000 V

Protective conductor

  • G = with GN-YE protective conductor
  • X = without protective conductor

Temperature range

  • Occasional flexing: -5°C to +70°C
  • Fixed installation: -40°C to +80°C

Product Datasheet