OMRON CP1E-N30S1DR-A CP1E-N30S1DR-A CP1W0175R CP1EN30S1DRA OMRON CPU S1 18/12 I/O AC Relay Outputs RS-232c + RS-485 8K + 8K View larger
Images are for illustrative purposes only. Please refer to data sheet for details

CP1E-N30S1DR-A CP1W0175R CP1EN30S1DRA OMRON CPU S1 18/12 I/O AC Relay Outputs RS-232c + RS-485 8K + 8K

CP1E-N30S1DR-A

CP1W0175R

CP1EN30S1DRA

OMRON

1 Pcs.

CPU S1 18/12 I/O AC Relay Outputs RS-232c + RS-485 8K + 8K PLC, 100-240 VAC supply, 18 x 24 VDC inputs, 12 x relay outputs 2 A, 8K steps program + 8K words data memory, RS-232C and RS-485 (half-duplex) port

Automation > PLC CPU-module
CPM2C

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Specifications

Supply voltage typeAC
Number of digital inputs18
Input typePNP/NPN
Number of digital outputs12
Output typeRelay
Program capacity8 K steps
Data memory capacity8 K words
Logic execution time1.19 µs
Communication port(s)Serial RS-232C, Serial RS-485, USB
Number of Ethernet ports0
Number of USB ports1
Number of RS-232 ports1
Number of RS-485 ports1
Communication option(s)CompoBus/S Slave, Serial RS-232C, Serial RS-422, Serial RS-485
Max. encoder input frequency100 kHz
Max. number of PTP axes0
Max. pulse output frequency0 kHz
Function Block programming
Battery-free memory backup
Real-time clock
Analog option boards
Max. number of analog I/O channels24
Max. number of local I/O points150
Max. number of expansion units3
Built-in auxiliary 24 VDC output300 mA
Operating temperature range0-55 °C
Height90 mm
Width130 mm
Depth79 mm

ETIM for 377333 PLC's (EC000236)
Feature Name Feature Value
Performance level according to EN ISO 13849-1 (EF007399) Level a
Model (EF000010) Compact
SIL according to IEC 61508 (EF009889) None
Voltage type (supply voltage) (EF002991) AC
Explosion safety category for gas (EF003997) None
Explosion safety category for dust (EF003998) None
Type of memory (EF002996) FLASH
Radio standard UMTS (EF008525) No
Appendant operation agent (Ex ib) (EF004142) No
Supporting protocol for other bus systems (EF003062) Yes
Supporting protocol for SERCOS (EF006657) No
IO link master (EF007298) No
Rack-assembly possible (EF007018) No
Supporting protocol for KNX (EF003055) No
Supporting protocol for LON (EF003017) No
Supporting protocol for SUCONET (EF003060) No
Supporting protocol for IEC 60870 (EF016069) No
Supporting protocol for EtherNet/IP (EF007521) No
Supporting protocol for DNP3 (EF016068) No
Radio standard GSM (EF008524) No
Supporting protocol for INTERBUS (EF003054) No
Supporting protocol for Data-Highway (EF003058) No
Supporting protocol for PROFINET IO (EF007525) No
Supporting protocol for DeviceNet (EF003059) No
Suitable for rail mounting (EF003972) Yes
Supporting protocol for IEC 61850 Ethernet (EF015389) No
Supporting protocol for INTERBUS-Safety (EF006662) No
Supporting protocol for PROFIsafe (EF007526) No
System accessory (EF004118) No
Supporting protocol for PROFIBUS (EF003052) No
Radio standard GPRS (EF008523) No
Supporting protocol for DeviceNet Safety (EF007520) No
Supporting protocol for TCP/IP (EF003050) No
Wall mounting/direct mounting (EF007020) Yes
Front built-in possible (EF007016) No
Supporting protocol for Foundation Fieldbus (EF007522) No
Additional program memory possible (EF003029) No
Supporting protocol for SafetyBUS p (EF007527) No
Appendant operation agent (Ex ia) (EF004141) No
Supporting protocol for Modbus (EF003057) Yes
Redundancy (EF003156) No
Supporting protocol for PROFINET CBA (EF007524) No
Radio standard Bluetooth (EF007178) No
Suitable for safety functions (EF001597) No
With display (EF000458) No
With optical interface (EF003028) No
Supporting protocol for CAN (EF003053) No
Supporting protocol for AS-Interface Safety at Work (EF007519) No
Radio standard WLAN 802.11 (EF007179) No
Supporting protocol for ASI (EF003051) No
Number of HW-interfaces other (EF003027) 0
Memory size (EF002997) 52 kByte
Number of interfaces PROFINET (EF006932) 0
Number of relay outputs (EF007348) 12
Number of HW-interfaces USB (EF003025) 1
Width (EF000008) 130 mm
Number of digital inputs (EF001992) 18
Depth (EF000049) 79 mm
Number of HW-interfaces wireless (EF006933) 0
Number of analogue inputs (EF001994) 0
Number of HW-interfaces parallel (EF003026) 0
Number of digital outputs (EF001993) 12
Number of HW-interfaces industrial Ethernet (EF003020) 0
Number of analogue outputs (EF001995) 0
Number of HW-interfaces RS-232 (EF003021) 1
Number of HW-interfaces RS-422 (EF003022) 0
Processing time (1K, binary operation) (EF003004) 1.1 ms
Number of HW-interfaces RS-485 (EF003023) 1
Height (EF000040) 90 mm
Max. number of time switches (EF007349) 255
Supply voltage AC 60 Hz (EF007533) 85 V
Supply voltage AC 50 Hz (EF007532) 85 V

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.