View larger
VG-C DCPH1000-4S
5088651
OBO BETTERMANN
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Anschlussart Generatoranschlusskasten | Tension spring terminal |
|---|---|
| CO2 Footprint (GWP) Cradle-to-Gate | 2,3932 kg CO2e / 1 Piece |
| Colour | Light grey; RAL 7035 |
| Conductor cross-section, rigid (single-wire/multiwire), max. | 6 mm² |
| Conductor cross-section, rigid (single-wire/multiwire), min. | 0,5 mm² |
| DC network form | yes |
| Depth | 122 mm |
| Dimension | 1000V DC |
| Entries per MPPT | 4 |
| Entry fuse | 10 A |
| Equipped with load-break switch | no |
| Exits per MPPT | 4 |
| For fuse size | 10x38 mm |
| Fuse type | gPV (full-range photovoltaic protection) [Bitte prüfen, ob so in Ordnung] |
| Installation type | Pre-mounted in the housing |
| IT network form | no |
| Lightning protection zone LPZ | 1→2 |
| Max. Input current per string | 30 A |
| Max. Input voltage DC | 1000 V |
| Max. Output current | 30 A |
| Maximum continuous voltage DC | 1000 V |
| Maximum discharge current (8/20 μs) | 40 kA |
| Monitoring function | no |
| Network form | DC |
| Nominal discharge current (8/20 µs) | 20 kA |
|---|---|
| Number of cable entries | 16 |
| Number of inputs | 4 |
| Number of MPPTs | 1 |
| Number of string inputs | 4 |
| Operating temperature, max. | 80 °C |
| Operating temperature, min. | -40 °C |
| Other network form | no |
| Permitted temperature range, max. | 80 °C |
| Permitted temperature range, min. | -40 °C |
| Protection rating | IP65 |
| Remote signalling | no |
| Response time | <25 ns |
| Signalling on device | Visual |
| SPD to EN 61643-11 | Type 2 |
| SPD to IEC 61643-1 | Class II |
| String fuse | 1-pole |
| TN network form | no |
| TN-C network form | no |
| TN-C-S network form | no |
| TN-S network form | no |
| TT network form | no |
| Type of entry | Gland |
| Version for | Type 2 in housing with 4 PV fuses (10 A) |