T0-1-8295/XZ
009760
EATON - MOELLER
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Product range | Control switches | ||
Part group reference | T0 | ||
Contacts | 2 | ||
Design | rear mounting Basic switch | ||
Contact sequence | |||
| General | |||
Standards | IEC/EN 60947, VDE 0660, IEC/EN 60204 Switch-disconnector according to IEC/EN 60947-3 | ||
Climatic proofing | Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 | ||
Ambient temperature | |||
Open | °C | -25 - +50 | |
Enclosed | °C | -25 - +40 | |
Overvoltage category/pollution degree | III/3 | ||
Rated impulse withstand voltage | Uimp | V AC | 6000 |
Mechanical shock resistance | g | 15 | |
Mounting position | As required | ||
Protection against direct contact when actuated from front (EN 50274) | Finger and back-of-hand proof | ||
| Contacts | |||
Electrical characteristics | |||
Rated operational voltage | Ue | V AC | 690 |
Rated uninterrupted current | Iu | A | 20 |
Note on rated uninterrupted current !u | Rated uninterrupted current Iu is specified for max. cross-section. | ||
Load rating with intermittent operation, class 12 | |||
AB 25 % DF | x Ie | 2 | |
AB 40 % DF | x Ie | 1.6 | |
AB 60 % DF | x Ie | 1.3 | |
Short-circuit rating | |||
Fuse | A gG/gL | 20 | |
Rated short-time withstand current (1 s current) | Icw | Arms | 320 |
Note on rated short-time withstand current lcw | Current for a time of 1 second | ||
Rated conditional short-circuit current | Iq | kA | 6 |
| Switching capacity | |||
cos ϕ rated making capacity as per IEC 60947-3 | A | 130 | |
Rated breaking capacity cos ϕ to IEC 60947-3 | A | ||
230 V | A | 100 | |
400/415 V | A | 110 | |
500 V | A | 80 | |
690 V | A | 60 | |
Safe isolation to EN 61140 | |||
between the contacts | V AC | 440 | |
Current heat loss per contact at Ie | W | 0.6 | |
Current heat loss per auxiliary circuit at Ie(AC-15/230 V) | CO | 0.6 | |
Lifespan, mechanical | Operations | x 106 | > 0.4 |
Maximum operating frequency | Operations/h | 1200 | |
AC | |||
AC-3 | |||
Rating, motor load switch | P | kW | |
220 V 230 V | P | kW | 3 |
230 V Star-delta | P | kW | 5.5 |
400 V 415 V | P | kW | 5.5 |
400 V Star-delta | P | kW | 7.5 |
500 V | P | kW | 5.5 |
500 V Star-delta | P | kW | 7.5 |
690 V | P | kW | 4 |
690 V Star-delta | P | kW | 5.5 |
Rated operational current motor load switch | |||
230 V | Ie | A | 11.5 |
230 V star-delta | Ie | A | 20 |
400V 415 V | Ie | A | 11.5 |
400 V star-delta | Ie | A | 20 |
500 V | Ie | A | 9 |
500 V star-delta | Ie | A | 15.6 |
690 V | Ie | A | 4.9 |
690 V star-delta | Ie | A | 8.5 |
AC-21A | |||
Rated operational current switch | |||
440 V | Ie | A | 20 |
AC-23A | |||
Motor rating AC-23A, 50 - 60 Hz | P | kW | |
230 V | P | kW | 3 |
400 V 415 V | P | kW | 5.5 |
500 V | P | kW | 7.5 |
690 V | P | kW | 5.5 |
Rated operational current motor load switch | |||
230 V | Ie | A | 13.3 |
400 V 415 V | Ie | A | 13.3 |
500 V | Ie | A | 13.3 |
690 V | Ie | A | 7.6 |
DC | |||
DC-1, Load-break switches L/R = 1 ms | |||
Rated operational current | Ie | A | 10 |
Voltage per contact pair in series | V | 60 | |
DC-21A | Ie | A | |
Rated operational current | Ie | A | 1 |
Contacts | Quantity | 1 | |
DC-23A, motor load switchL/R = 15 ms | |||
24 V | |||
Rated operational current | Ie | A | 10 |
Contacts | Quantity | 1 | |
48 V | |||
Rated operational current | Ie | A | 10 |
Contacts | Quantity | 2 | |
60 V | |||
Rated operational current | Ie | A | 10 |
Contacts | Quantity | 3 | |
120 V | |||
Rated operational current | Ie | A | 5 |
Contacts | Quantity | 3 | |
240 V | |||
Rated operational current | Ie | A | 5 |
Contacts | Quantity | 5 | |
DC-13, Control switches L/R = 50 ms | |||
Rated operational current | Ie | A | 10 |
Voltage per contact pair in series | V | 32 | |
Control circuit reliability at 24 V DC, 10 mA | Fault probability | HF | < 10-5, < 1 fault in 100000 operations |
| Terminal capacities | |||
Solid or stranded | mm2 | 1 x (1 - 2,5) 2 x (1 - 2,5) | |
Flexible with ferrules to DIN 46228 | mm2 | 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) | |
Terminal screw | M3.5 | ||
Max. tightening torque | Nm | 1 | |
| Technical safety parameters: | |||
Notes | B10dvalues as per EN ISO 13849-1, table C1 | ||
| Low-voltage industrial components (EG000017) / Control switch (EC002611) | |||
| Electric engineering, automation, process control engineering / Low-voltage switch technology / Off-load switch, circuit breaker, control switch / Control switch ([email protected] [ACN998008]) | |||
Type of switch | Reverser | ||
Number of poles | 1 | ||
Max. rated operation voltage Ue AC | V | 690 | |
Rated permanent current Iu | A | 20 | |
Number of switch positions | 2 | ||
With 0 (off) position | No | ||
With retraction in 0-position | No | ||
Device construction | Built-in device | ||
Width in number of modular spacings | 0 | ||
Suitable for ground mounting | Yes | ||
Suitable for front mounting 4-hole | No | ||
Suitable for distribution board installation | No | ||
Suitable for intermediate mounting | Yes | ||
Complete device in housing | No | ||
Type of control element | - | ||
Front shield size | 48x48 mm | ||
Degree of protection (IP), front side | IP00 | ||
| Feature Name | Feature Value |
|---|---|
| With zero (off) position (EF001416) | No |
| With retraction in 0-position (EF002428) | No |
| Suitable for floor mounting (EF007243) | No |
| Suitable for front mounting (EF007246) | No |
| Suitable for distribution board installation (EF007262) | No |
| Suitable for intermediate mounting (EF007264) | No |
| Complete device in housing (EF007317) | No |