EATON - MOELLER T0-1-8295/XZ T0-1-8295/XZ 009760 EATON ELECTRIC Changeover switch, 1p, Ie 12A, 45°, momentary, replacement switch, base f.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

T0-1-8295/XZ 009760 EATON ELECTRIC Changeover switch, 1p, Ie 12A, 45°, momentary, replacement switch, base f..

T0-1-8295/XZ

009760

EATON - MOELLER

1 Pcs.

Changeover switch, 1p, Ie=12A, 45°, momentary, replacement switch, base fixing Cam switch according to IEC/EN60947, size T0, without handle, snap screw-floor fastener, rated uninterrupted current Iu 20A, rated operating voltage Ue 690V, deliverable accessories according to catalog information cam switch T. General designs: insulation-material add-on housing, flush mounting, center mounting, rear mounting IVS service distribution board mounting.

Automation > Control switch
Disconnectors and Cam Switches

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Delivery programme
Product range
Control switches
Part group reference
T0
Contacts
2
Design
rear mounting
Basic switch
Contact sequence
General
Standards
IEC/EN 60947, VDE 0660, IEC/EN 60204
Switch-disconnector according to IEC/EN 60947-3
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
Open
°C -25 - +50
Enclosed
°C -25 - +40
Overvoltage category/pollution degree
III/3
Rated impulse withstand voltage
Uimp V AC 6000
Mechanical shock resistance
g 15
Mounting position
As required
Protection against direct contact when actuated from front (EN 50274)
Finger and back-of-hand proof
Contacts
Electrical characteristics
Rated operational voltage
Ue V AC 690
Rated uninterrupted current
Iu A 20
Note on rated uninterrupted current !u
Rated uninterrupted current Iu is specified for max. cross-section.
Load rating with intermittent operation, class 12
AB 25 % DF
x Ie 2
AB 40 % DF
x Ie 1.6
AB 60 % DF
x Ie 1.3
Short-circuit rating
Fuse
A gG/gL 20
Rated short-time withstand current (1 s current)
Icw Arms 320
Note on rated short-time withstand current lcw
Current for a time of 1 second
Rated conditional short-circuit current
Iq kA 6
Switching capacity
cos ϕ rated making capacity as per IEC 60947-3
A 130
Rated breaking capacity cos ϕ to IEC 60947-3
A
230 V
A 100
400/415 V
A 110
500 V
A 80
690 V
A 60
Safe isolation to EN 61140
between the contacts
V AC 440
Current heat loss per contact at Ie
W 0.6
Current heat loss per auxiliary circuit at Ie(AC-15/230 V)
CO 0.6
Lifespan, mechanical
Operations x 106 > 0.4
Maximum operating frequency
Operations/h 1200
AC
AC-3
Rating, motor load switch
P kW
220 V 230 V
P kW 3
230 V Star-delta
P kW 5.5
400 V 415 V
P kW 5.5
400 V Star-delta
P kW 7.5
500 V
P kW 5.5
500 V Star-delta
P kW 7.5
690 V
P kW 4
690 V Star-delta
P kW 5.5
Rated operational current motor load switch
230 V
Ie A 11.5
230 V star-delta
Ie A 20
400V 415 V
Ie A 11.5
400 V star-delta
Ie A 20
500 V
Ie A 9
500 V star-delta
Ie A 15.6
690 V
Ie A 4.9
690 V star-delta
Ie A 8.5
AC-21A
Rated operational current switch
440 V
Ie A 20
AC-23A
Motor rating AC-23A, 50 - 60 Hz
P kW
230 V
P kW 3
400 V 415 V
P kW 5.5
500 V
P kW 7.5
690 V
P kW 5.5
Rated operational current motor load switch
230 V
Ie A 13.3
400 V 415 V
Ie A 13.3
500 V
Ie A 13.3
690 V
Ie A 7.6
DC
DC-1, Load-break switches L/R = 1 ms
Rated operational current
Ie A 10
Voltage per contact pair in series
V 60
DC-21A
Ie A
Rated operational current
Ie A 1
Contacts
Quantity 1
DC-23A, motor load switchL/R = 15 ms
24 V
Rated operational current
Ie A 10
Contacts
Quantity 1
48 V
Rated operational current
Ie A 10
Contacts
Quantity 2
60 V
Rated operational current
Ie A 10
Contacts
Quantity 3
120 V
Rated operational current
Ie A 5
Contacts
Quantity 3
240 V
Rated operational current
Ie A 5
Contacts
Quantity 5
DC-13, Control switches L/R = 50 ms
Rated operational current
Ie A 10
Voltage per contact pair in series
V 32
Control circuit reliability at 24 V DC, 10 mA
Fault probability HF < 10-5, < 1 fault in 100000 operations
Terminal capacities
Solid or stranded
mm2 1 x (1 - 2,5)
2 x (1 - 2,5)
Flexible with ferrules to DIN 46228
mm2 1 x (0.75 - 2.5)
2 x (0.75 - 2.5)
Terminal screw
M3.5
Max. tightening torque
Nm 1
Technical safety parameters:
Notes
B10dvalues as per EN ISO 13849-1, table C1
Technical data ETIM 6.0(Show features)(Hide features)
Low-voltage industrial components (EG000017) / Control switch (EC002611)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Off-load switch, circuit breaker, control switch / Control switch ([email protected] [ACN998008])
Type of switch
Reverser
Number of poles
1
Max. rated operation voltage Ue AC
V 690
Rated permanent current Iu
A 20
Number of switch positions
2
With 0 (off) position
No
With retraction in 0-position
No
Device construction
Built-in device
Width in number of modular spacings
0
Suitable for ground mounting
Yes
Suitable for front mounting 4-hole
No
Suitable for distribution board installation
No
Suitable for intermediate mounting
Yes
Complete device in housing
No
Type of control element
-
Front shield size
48x48 mm
Degree of protection (IP), front side
IP00
Additional product information (links)
>>

ETIM for 009760 Low-voltage industrial controls and switchgear (EC002611)
Feature Name Feature Value
With zero (off) position (EF001416) No
With retraction in 0-position (EF002428) No
Suitable for floor mounting (EF007243) No
Suitable for front mounting (EF007246) No
Suitable for distribution board installation (EF007262) No
Suitable for intermediate mounting (EF007264) No
Complete device in housing (EF007317) No

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.