T0-1-8295/XZ 009760 EATON ELECTRIC Changeover switch, 1p, Ie 12A, 45°, momentary, replacement switch, base f..
T0-1-8295/XZ
009760
EATON - MOELLER
1 Pcs.
Automation > Control switch
Disconnectors and Cam Switches
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Changeover switches allow manual or automated switching of electrical loads between primary and alternative supply sources to maintain continuous process operations. The Eaton Moeller T0-1-8295/XZ component provides dependable performance for base mounting applications. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated impulse withstand voltage: U imp
- Rated operational voltage: U e Rated uninterrupted current: I u
- Rated short-time withstand current (1 s current): I cw
- Rated conditional short-circuit current: Iq
- Lifespan, mechanical: Operations
- Maximum operating frequency: Operations/h
- Rating, motor load switch: P
- 220 V 230 V: P
- 230 V Star-delta: P
- 400 V 415 V: P
- 400 V Star-delta: P
- 500 V: P
- 500 V Star-delta: P
- 690 V: P
- 690 V Star-delta: P
More info
▲Product range | Control switches | ||
Part group reference | T0 | ||
Contacts | 2 | ||
Design | rear mounting Basic switch | ||
Contact sequence | |||
| General | |||
Standards | IEC/EN 60947, VDE 0660, IEC/EN 60204 Switch-disconnector according to IEC/EN 60947-3 | ||
Climatic proofing | Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 | ||
Ambient temperature | |||
Open | °C | -25 - +50 | |
Enclosed | °C | -25 - +40 | |
Overvoltage category/pollution degree | III/3 | ||
Rated impulse withstand voltage | Uimp | V AC | 6000 |
Mechanical shock resistance | g | 15 | |
Mounting position | As required | ||
Protection against direct contact when actuated from front (EN 50274) | Finger and back-of-hand proof | ||
| Contacts | |||
Electrical characteristics | |||
Rated operational voltage | Ue | V AC | 690 |
Rated uninterrupted current | Iu | A | 20 |
Note on rated uninterrupted current !u | Rated uninterrupted current Iu is specified for max. cross-section. | ||
Load rating with intermittent operation, class 12 | |||
AB 25 % DF | x Ie | 2 | |
AB 40 % DF | x Ie | 1.6 | |
AB 60 % DF | x Ie | 1.3 | |
Short-circuit rating | |||
Fuse | A gG/gL | 20 | |
Rated short-time withstand current (1 s current) | Icw | Arms | 320 |
Note on rated short-time withstand current lcw | Current for a time of 1 second | ||
Rated conditional short-circuit current | Iq | kA | 6 |
| Switching capacity | |||
cos ϕ rated making capacity as per IEC 60947-3 | A | 130 | |
Rated breaking capacity cos ϕ to IEC 60947-3 | A | ||
230 V | A | 100 | |
400/415 V | A | 110 | |
500 V | A | 80 | |
690 V | A | 60 | |
Safe isolation to EN 61140 | |||
between the contacts | V AC | 440 | |
Current heat loss per contact at Ie | W | 0.6 | |
Current heat loss per auxiliary circuit at Ie(AC-15/230 V) | CO | 0.6 | |
Lifespan, mechanical | Operations | x 106 | > 0.4 |
Maximum operating frequency | Operations/h | 1200 | |
AC | |||
AC-3 | |||
Rating, motor load switch | P | kW | |
220 V 230 V | P | kW | 3 |
230 V Star-delta | P | kW | 5.5 |
400 V 415 V | P | kW | 5.5 |
400 V Star-delta | P | kW | 7.5 |
500 V | P | kW | 5.5 |
500 V Star-delta | P | kW | 7.5 |
690 V | P | kW | 4 |
690 V Star-delta | P | kW | 5.5 |
Rated operational current motor load switch | |||
230 V | Ie | A | 11.5 |
230 V star-delta | Ie | A | 20 |
400V 415 V | Ie | A | 11.5 |
400 V star-delta | Ie | A | 20 |
500 V | Ie | A | 9 |
500 V star-delta | Ie | A | 15.6 |
690 V | Ie | A | 4.9 |
690 V star-delta | Ie | A | 8.5 |
AC-21A | |||
Rated operational current switch | |||
440 V | Ie | A | 20 |
AC-23A | |||
Motor rating AC-23A, 50 - 60 Hz | P | kW | |
230 V | P | kW | 3 |
400 V 415 V | P | kW | 5.5 |
500 V | P | kW | 7.5 |
690 V | P | kW | 5.5 |
Rated operational current motor load switch | |||
230 V | Ie | A | 13.3 |
400 V 415 V | Ie | A | 13.3 |
500 V | Ie | A | 13.3 |
690 V | Ie | A | 7.6 |
DC | |||
DC-1, Load-break switches L/R = 1 ms | |||
Rated operational current | Ie | A | 10 |
Voltage per contact pair in series | V | 60 | |
DC-21A | Ie | A | |
Rated operational current | Ie | A | 1 |
Contacts | Quantity | 1 | |
DC-23A, motor load switchL/R = 15 ms | |||
24 V | |||
Rated operational current | Ie | A | 10 |
Contacts | Quantity | 1 | |
48 V | |||
Rated operational current | Ie | A | 10 |
Contacts | Quantity | 2 | |
60 V | |||
Rated operational current | Ie | A | 10 |
Contacts | Quantity | 3 | |
120 V | |||
Rated operational current | Ie | A | 5 |
Contacts | Quantity | 3 | |
240 V | |||
Rated operational current | Ie | A | 5 |
Contacts | Quantity | 5 | |
DC-13, Control switches L/R = 50 ms | |||
Rated operational current | Ie | A | 10 |
Voltage per contact pair in series | V | 32 | |
Control circuit reliability at 24 V DC, 10 mA | Fault probability | HF | < 10-5, < 1 fault in 100000 operations |
| Terminal capacities | |||
Solid or stranded | mm2 | 1 x (1 - 2,5) 2 x (1 - 2,5) | |
Flexible with ferrules to DIN 46228 | mm2 | 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) | |
Terminal screw | M3.5 | ||
Max. tightening torque | Nm | 1 | |
| Technical safety parameters: | |||
Notes | B10dvalues as per EN ISO 13849-1, table C1 | ||
| Low-voltage industrial components (EG000017) / Control switch (EC002611) | |||
| Electric engineering, automation, process control engineering / Low-voltage switch technology / Off-load switch, circuit breaker, control switch / Control switch ([email protected] [ACN998008]) | |||
Type of switch | Reverser | ||
Number of poles | 1 | ||
Max. rated operation voltage Ue AC | V | 690 | |
Rated permanent current Iu | A | 20 | |
Number of switch positions | 2 | ||
With 0 (off) position | No | ||
With retraction in 0-position | No | ||
Device construction | Built-in device | ||
Width in number of modular spacings | 0 | ||
Suitable for ground mounting | Yes | ||
Suitable for front mounting 4-hole | No | ||
Suitable for distribution board installation | No | ||
Suitable for intermediate mounting | Yes | ||
Complete device in housing | No | ||
Type of control element | - | ||
Front shield size | 48x48 mm | ||
Degree of protection (IP), front side | IP00 | ||