S811+T24V3S
168989
EATON - MOELLER
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Description | With internal bypass contacts | ||
Function | Soft starter for three-phase loads, with control unit and pump algorithm, for 690-V grids | ||
Mains supply voltage (50/60 Hz) | ULN | V AC | 200 - 690 |
Supply voltage | Us | 24 V DC | |
Control voltage | UC | 24 V DC | |
Assigned motor rating (Standard connection, In-Line) | |||
at 400 V, 50 Hz | P | kW | 132 |
at 690 V, 50 Hz | P | kW | 200 |
at 460 V, 60 Hz | P | HP | 200 |
Rated operational current | |||
AC-53 | Ie | A | 240 |
Startup class | CLASS 10 (star-delta replacement) CLASS 20 (heavy starting duty 3 x Iefor 45 s) CLASS 30 (6 x Iefor 30 s) | ||
Rated operational voltage | Ue | 200 V 230 V 400 V 480 V 600 V 690 V | |
Connection to SmartWire-DT | no | ||
Frame size | T | ||
Ordering information | Terminal blocks for the terminals are required for frame sizes T, U, and V -> Accessories |
| General | |||
Standards | IEC/EN 60947-4-2 UL 508 CSA22.2-14-1995 GB14048 | ||
Approvals | CE | ||
Approvals | UL CSA C-Tick CCC | ||
Climatic proofing | Damp heat, constant, to IEC 60068-2-3 Damp heat, cyclic, to IEC 60068-2-10 | ||
Ambient temperature | |||
Operation | ϑ | °C | -30 - +50 |
Storage | ϑ | °C | -50 - +70 |
Altitude | m | 0 - 2000 m, above that each 100 m 0.5% Derating | |
Mounting position | As required | ||
Degree of protection | |||
Degree of Protection | IP20 (terminals IP00) | ||
Integrated | An IP20 degree of protection can be achieved on all sides by using optional terminal covers SS-IP20-TU. | ||
Protection against direct contact | Finger- and back-of-hand proof | ||
Overvoltage category/pollution degree | II/3 | ||
Shock resistance | 15 g | ||
Radio interference level (IEC/EN 55011) | A | ||
Static heat dissipation, non-current-dependent | Pvs | W | 25 |
Weight | kg | 18.6 | |
| Main conducting paths | |||
Rated operating voltage | Ue | V AC | 200 - 690 |
Supply frequency | fLN | Hz | 50/60 |
Rated operational current | Ie | A | |
AC-53 | Ie | A | 240 |
Assigned motor rating (Standard connection, In-Line) | |||
at 230 V, 50 Hz | P | kW | 75 |
at 400 V, 50 Hz | P | kW | 132 |
at 500 V, 50 Hz | P | kW | 160 |
at 690 V, 50 Hz | P | kW | 200 |
at 200 V, 60 Hz | P | HP | 75 |
at 230 V, 60 Hz | P | HP | 75 |
at 460 V, 60 Hz | P | HP | 200 |
at 600 V, 60 Hz | P | HP | 200 |
at 690 V, 60 Hz | P | HP | 250 |
Assigned motor rating (delta connection) | |||
at 690 V, 60 Hz | P | HP | 500 |
Overload cycle to IEC/EN 60947-4-2 | |||
AC-53a | 240 A: AC-53a: 4.0 - 32: 99 - 3 | ||
Internal bypass contacts | |||
Technical data for design verification | |||
Rated operational current for specified heat dissipation | In | A | 240 |
Heat dissipation per pole, current-dependent | Pvid | W | 0 |
Equipment heat dissipation, current-dependent | Pvid | W | 25 |
Static heat dissipation, non-current-dependent | Pvs | W | 25 |
Heat dissipation capacity | Pdiss | W | 0 |
Operating ambient temperature min. | °C | -30 | |
Operating ambient temperature max. | °C | 50 | |
IEC/EN 61439 design verification | |||
10.2 Strength of materials and parts | |||
10.2.2 Corrosion resistance | Meets the product standard's requirements. | ||
10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. | ||
10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. | ||
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects | Meets the product standard's requirements. | ||
10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. | ||
10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.7 Inscriptions | Meets the product standard's requirements. | ||
10.3 Degree of protection of ASSEMBLIES | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.4 Clearances and creepage distances | Meets the product standard's requirements. | ||
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. | ||
10.8 Connections for external conductors | Is the panel builder's responsibility. | ||
10.9 Insulation properties | |||
10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. | ||
10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. | ||
10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. | ||
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. | ||
10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. | ||
10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. | ||
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. | ||
| Low-voltage industrial components (EG000017) / Soft starter (EC000640) | |||
| Electric engineering, automation, process control engineering / Low-voltage switch technology / Load breakout, motor breakout / Semiconductor motor controller or soft starter ([email protected] [ACO300008]) | |||
Rated operation current Ie at 40 °C Tu | A | 240 | |
Rated operating voltage Ue | V | 200 - 690 | |
Rated power three-phase motor, inline, at 230 V | kW | 75 | |
Rated power three-phase motor, inline, at 400 V | kW | 132 | |
Rated power three-phase motor, inside delta, at 230 V | kW | 132 | |
Rated power three-phase motor, inside delta, at 400 V | kW | 200 | |
Internal bypass | Yes | ||
With display | Yes | ||
Torque control | No | ||
Rated surrounding temperature without derating | °C | 50 | |
Rated control supply voltage Us at AC 50HZ | V | 0 - 0 | |
Rated control supply voltage Us at AC 60HZ | V | 0 - 0 | |
Rated control supply voltage Us at DC | V | 24 - 24 | |
Voltage type for actuating | DC | ||
Integrated motor overload protection | Yes | ||
| Feature Name | Feature Value |
|---|---|
| Rated operation current Ie at 40 °C Tu (EF007039) | 240 A |
| Rated operating voltage Ue (EF002418) | 200 V |
| Rated power three-phase motor, inline, at 230 V (EF007053) | 75 kW |
| Rated power three-phase motor, inline, at 400 V (EF007054) | 132 kW |
| Rated power three-phase motor, inside delta, at 230 V (EF007055) | 132 kW |
| Rated power three-phase motor, inside delta, at 400 V (EF007056) | 200 kW |
| Function (EF000030) | Single direction |
| Internal bypass (EF009214) | Yes |
| With display (EF000458) | Yes |
| Torque control (EF009215) | No |
| Rated surrounding temperature without derating (EF007074) | 50 °C |
| Rated control supply voltage AC 50 Hz (EF003978) | 0 V |
| Rated control supply voltage AC 60 Hz (EF003979) | 0 V |
| Rated control supply voltage DC (EF003980) | 24 V |
| Voltage type for actuating (EF008242) | DC |
| Integrated motor overload protection (EF007297) | Yes |
| Release class (EF006668) | Adjustable |
| Degree of protection (IP) (EF005474) | IP00 |