View larger
XN-GW-CANOPEN
140050
EATON - MOELLER
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Function | Gateways XI/ON | ||
Connection technique | Tension spring connection | ||
Function | XN gateway without integrated supply | ||
Short Description | supports up to 74 disc-type modules (XN) 1 x 9-pole SUB-D socket 1 x 9‑pinSUB‑Dplug connector Address setting with two hexadecimal rotary coding switch Address range: 1 – 127 (dec.) | ||
Field bus connection | CANopen® | ||
Terminal capacity (field bus/supply voltage) | 2 × spring-cage terminal strips for direct wiring | ||
Service interface | PS/2 socket | ||
Data transfer rate | 1000 Kbit/s 800 Kbit/s 500 Kbit/s 250 Kbit/s 125 kbit/s 50 Kbit/s 20 Kbit/s 10 Kbit/s | ||
| Instructions The supply module XN-BR-24VDC-D must be mounted immediately next to the gateway to provide the supply for the gateway. | |||
| Information about equipment supplied The delivery package for all gateways includes: 2 x end bracket XN-WEW-32/2-SW, 1 x end plate XN-ABPL | |||
| General | |||
Standards | EN 61000-6-2 EN 61000-6-4 EN 61131-2 | ||
Potential isolation | Yes, through optocoupler | ||
Ambient temperature | °C | 0 - +55 | |
Storage | ϑ | °C | -25 - +85 |
Relative humidity | 5 - 95 % (indoor), Level RH-2, no condensation (for storage at 45°C) | ||
Harmful gases | ppm | SO2: 10 (rel. humidity < 75%, no condensation) H2S: 1.0 (rel. humidity < 75 %,no condensation) | |
Vibration | according to IEC/EN 60068-2-6 | ||
Mechanical shock resistance | g | according to IEC 60068-2-27 | |
Continuous shock resistance (IEC/EN 60068-2-29) | According to IEC 60068-2-29 | ||
Drop and topple | According to IEC 60068-2-31, free fall according to IEC 60068-2-32 | ||
Degree of Protection | IP20 | ||
Electromagnetic compatibility (EMC) | |||
ESD | kV | EN 61100-4-2 | |
Electromagnetic fields | V/m | EN 61100-4-2 | |
Burst | EN 61100-4-4 | ||
Surge | EN 61100-4-5 | ||
Radiated RFI | V | EN 61100-4-6 | |
Emitted interference (radiated, high frequency) | dB | EN 55016-2-3 | |
Voltage fluctuations/voltage dips | EN 61131-2 | ||
Type test | to EN 61131-2 | ||
Approvals | CE, cULus | ||
Static heat dissipation, non-current-dependent | Pvs | W | 2.5 |
Other technical data (sheet catalogue) | >Technical Data | ||
| Terminations | |||
Rated data | according to VDE 0611 Part 1/8.92/IEC/EN 60947-7-1 | ||
Connection design in TOP direction | Spring-loaded/screw terminal | ||
Stripping length | mm | 8 | |
Clamping range | max. 0.5 - 2.5 mm2 | ||
Connectable conductors | |||
Solid | mm2 | 0.5 - 2.5 | |
Flexible without ferrule | mm2 | 0.5 - 1.5 | |
Flexible with ferrule | mm2 | 0.5 - 1.5 | |
Flexible with ferrule | mm2 | 0.5 - 1.5 | |
Gauge pin IEC/EN 60947-1 | A1 | ||
| Networking | |||
Bus | CANopen® | ||
Bus protocol | CANopen® | ||
Maximum station configuration | 74 cards (XN) of slice design or max. length of station: 1 m | ||
System supply | Usys | V DC | 24 /5 |
Operational voltage | V DC | 5 (from bus refreshing module) | |
Admissible range | 4.7-5.3 V DC | ||
Residual ripple | % | According to EN 61131-2 | |
Rated current consumption from module bus | IMB | mA | |
Technical data for design verification | |||
Rated operational current for specified heat dissipation | In | A | 0 |
Heat dissipation per pole, current-dependent | Pvid | W | 0 |
Equipment heat dissipation, current-dependent | Pvid | W | 0 |
Static heat dissipation, non-current-dependent | Pvs | W | 2.5 |
Heat dissipation capacity | Pdiss | W | 0 |
Operating ambient temperature min. | °C | 0 | |
Operating ambient temperature max. | °C | 55 | |
Degree of Protection | IP20 | ||
IEC/EN 61439 design verification | |||
10.2 Strength of materials and parts | |||
10.2.2 Corrosion resistance | Meets the product standard's requirements. | ||
10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. | ||
10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. | ||
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects | Meets the product standard's requirements. | ||
10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. | ||
10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.7 Inscriptions | Meets the product standard's requirements. | ||
10.3 Degree of protection of ASSEMBLIES | Meets the product standard's requirements. | ||
10.4 Clearances and creepage distances | Meets the product standard's requirements. | ||
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. | ||
10.8 Connections for external conductors | Is the panel builder's responsibility. | ||
10.9 Insulation properties | |||
10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. | ||
10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. | ||
10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. | ||
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. | ||
10.11 Short-circuit rating | Is the panel builder's responsibility. | ||
10.12 Electromagnetic compatibility | Is the panel builder's responsibility. | ||
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. | ||
Supply voltage AC 50 Hz | V | 0 - 0 | |
Supply voltage AC 60 Hz | V | 0 - 0 | |
Supply voltage DC | V | 18 - 30 | |
Voltage type of supply voltage | DC | ||
Supporting protocol in-bound for TCP/IP | No | ||
Supporting protocol in-bound for PROFIBUS | No | ||
Supporting protocol in-bound for CAN | Yes | ||
Supporting protocol in-bound for INTERBUS | No | ||
Supporting protocol in-bound for ASI | No | ||
Supporting protocol in-bound for EIB/KNX | No | ||
Supporting protocol in-bound for MODBUS | No | ||
Supporting protocol in-bound for Data-highway | No | ||
Supporting protocol in-bound for DeviceNet | No | ||
Supporting protocol in-bound for SUCONET | No | ||
Supporting protocol in-bound for LON | No | ||
Supporting protocol in-bound for SERCOS | No | ||
Supporting protocol in-bound for PROFINET IO | No | ||
Supporting protocol in-bound for PROFINET CBA | No | ||
Supporting protocol in-bound for Foundation Fieldbus | No | ||
Supporting protocol in-bound for EtherNet/IP | No | ||
Supporting protocol in-bound for AS-Interface Safety at Work | No | ||
Supporting protocol in-bound for DeviceNet Safety | No | ||
Supporting protocol in-bound for INTERBUS-Safety | No | ||
Supporting protocol in-bound for PROFIsafe | No | ||
Supporting protocol in-bound for SafetyBUS p | No | ||
Supporting protocol in-bound for other bus systems | No | ||
Supporting protocol out-bound for TCP/IP | No | ||
Supporting protocol out-bound for PROFIBUS | No | ||
Supporting protocol out-bound for CAN | Yes | ||
Supporting protocol out-bound for INTERBUS | No | ||
Supporting protocol out-bound for ASI | No | ||
Supporting protocol out-bound for EIB/KNX | No | ||
Supporting protocol out-bound for MODBUS | No | ||
Supporting protocol out-bound for Data-highway | No | ||
Supporting protocol out-bound for DeviceNet | No | ||
Supporting protocol out-bound for SUCONET | No | ||
Supporting protocol out-bound for LON | No | ||
Supporting protocol out-bound for SERCOS | No | ||
Supporting protocol out-bound for PROFINET IO | No | ||
Supporting protocol out-bound for PROFINET CBA | No | ||
Supporting protocol out-bound for Foundation Fieldbus | No | ||
Supporting protocol out-bound for EtherNet/IP | No | ||
Supporting protocol out-bound for AS-Interface Safety at Work | No | ||
Supporting protocol out-bound for DeviceNet Safety | No | ||
Supporting protocol out-bound for INTERBUS-Safety | No | ||
Supporting protocol out-bound for PROFIsafe | No | ||
Supporting protocol out-bound for SafetyBUS p | No | ||
Supporting protocol out-bound for other bus systems | No | ||
Radiostandard Bluetooth | No | ||
Radiostandard WLAN 802.11 | No | ||
IO link master | No | ||
System accessory | Yes | ||
Degree of protection (IP) | IP20 | ||
With potential separation | Yes | ||
Fieldbus connection over separate bus coupler possible | No | ||
Rail mounting possible | Yes | ||
Wall mounting/direct mounting | No | ||
Front build in possible | No | ||
Rack-assembly possible | No | ||
Suited for safety functions | No | ||
Safety class according to DIN V 19250 | 0 | ||
Category according to EN 954-1 | - | ||
SIL according to IEC 61508 | 0 | ||
SIL according to IEC 62061 | 0 | ||
Performance level acc. to EN ISO 13849-1 | - | ||
Appendant operation agent (Ex ia) | No | ||
Appendant operation agent (Ex ib) | No | ||
Explosion safety category for gas | None | ||
Explosion safety category for dust | None | ||
Width | mm | 50.6 | |
Height | mm | 114.8 | |
Depth | mm | 74.4 |
| Product Standards | UL 508; CSA-C22.2 No. 142; IEC/EN 6113-2; CE marking | ||
| UL File No. | E205091 | ||
| UL Category Control No. | NRAQ, NRAQ7 | ||
| CSA File No. | UL report applies to both US and Canada | ||
| CSA Class No. | 2252-01, 2252-81 | ||
| North America Certification | UL recognized, certified by UL for use in Canada | ||
| Specially designed for North America | No | ||
| Current Limiting Circuit-Breaker | No | ||
| Degree of Protection | IEC: IP20, UL/CSA Type: - |
| Feature Name | Feature Value |
|---|---|
| Supporting protocol for EtherCAT (EF017564) | No |
| Supporting protocol for TCP/IP (EF003050) | No |
| Supporting protocol for PROFIBUS (EF003052) | No |
| Supporting protocol for CAN (EF003053) | No |
| Supporting protocol for INTERBUS (EF003054) | No |
| Supporting protocol for ASI (EF003051) | No |
| Supporting protocol for KNX (EF003055) | No |
| Supporting protocol for Modbus (EF003057) | No |
| Supporting protocol for Data-Highway (EF003058) | No |
| Supporting protocol for DeviceNet (EF003059) | No |
| Supporting protocol for SUCONET (EF003060) | No |
| Supporting protocol for LON (EF003017) | No |
| Supporting protocol for SERCOS (EF006657) | No |
| Supporting protocol for PROFINET IO (EF007525) | No |
| Supporting protocol for PROFINET CBA (EF007524) | No |
| Supporting protocol for Foundation Fieldbus (EF007522) | No |
| Supporting protocol for EtherNet/IP (EF007521) | No |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | No |
| Supporting protocol for DeviceNet Safety (EF007520) | No |
| Supporting protocol for INTERBUS-Safety (EF006662) | No |
| Supporting protocol for PROFIsafe (EF007526) | No |
| Supporting protocol for SafetyBUS p (EF007527) | No |
| Supporting protocol for other bus systems (EF003062) | No |
| Radio standard Bluetooth (EF007178) | No |
| Radio standard WLAN 802.11 (EF007179) | No |
| Radio standard GPRS (EF008523) | No |
| Radio standard eGPRS (EF009703) | No |
| Radio standard GSM (EF008524) | No |
| Radio standard LTE (EF009709) | No |
| Radio standard UMTS (EF008525) | No |
| IO link master (EF007298) | No |
| System accessory (EF004118) | No |
| With potential separation (EF003272) | No |
| Fieldbus connection over separate bus coupler possible (EF004002) | No |
| Suitable for rail mounting (EF003972) | No |
| Wall mounting/direct mounting (EF007020) | No |
| Front built-in possible (EF007016) | No |
| Rack-assembly possible (EF007018) | No |
| Suitable for safety functions (EF001597) | No |
| Appendant operation agent (Ex ia) (EF004141) | No |
| Appendant operation agent (Ex ib) (EF004142) | No |
| Certified for UL hazardous location class I (EF017622) | No |
| Certified for UL hazardous location class II (EF017625) | No |
| Certified for UL hazardous location class III (EF017627) | No |
| Certified for UL hazardous location division 1 (EF017628) | No |
| Certified for UL hazardous location division 2 (EF017629) | No |
| Certified for UL hazardous location group A (acetylene) (EF017632) | No |
| Certified for UL hazardous location group B (hydrogen) (EF017633) | No |
| Certified for UL hazardous location group C (ethylene) (EF017635) | No |
| Certified for UL hazardous location group D (propane) (EF017636) | No |
| Certified for UL hazardous location group E (metal dusts) (EF017637) | No |
| Certified for UL hazardous location group F (carbonaceous dusts) (EF017638) | No |
| Certified for UL hazardous location group G (non-conductive dusts) (EF017639) | No |
| Width (EF000008) | 80 mm |
| Height (EF000040) | 60 mm |
| Depth (EF000049) | 120 mm |