XN-GW-CANOPEN 140050 EATON ELECTRIC CANopen Gateway 85 50 225163
XN-GW-CANOPEN
140050
EATON - MOELLER
1 Pcs.
Automation > Fieldbus, decentr. periphery - communication module
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Eaton Moeller XN-GW-CANOPEN is a CANopen Gateway designed to link modular I/O islands to higher-level automation networks in industrial control systems. These gateways manage data exchange between field devices and the master controller, enabling seamless communication across decentralized architectures.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Storage: ϑ
- Static heat dissipation, non-current-dependent: P vs
- System supply: U sys
- Rated current consumption from module bus: I MB
- Rated operational current for specified heat dissipation: I n
- Heat dissipation per pole, current-dependent: P vid
- Equipment heat dissipation, current-dependent: P vid
- Heat dissipation capacity: P diss
- MN05002005Z User manual XI/ON gateways for CANopen: >
- Supporting protocol for TCP/IP (EF003050): No
- Supporting protocol for PROFIBUS (EF003052): No
- Supporting protocol for CAN (EF003053): No
- Supporting protocol for INTERBUS (EF003054): No
- Supporting protocol for ASI (EF003051): No
- Supporting protocol for KNX (EF003055): No
More info
▲Function | Gateways XI/ON | ||
Connection technique | Tension spring connection | ||
Function | XN gateway without integrated supply | ||
Short Description | supports up to 74 disc-type modules (XN) 1 x 9-pole SUB-D socket 1 x 9‑pinSUB‑Dplug connector Address setting with two hexadecimal rotary coding switch Address range: 1 – 127 (dec.) | ||
Field bus connection | CANopen® | ||
Terminal capacity (field bus/supply voltage) | 2 × spring-cage terminal strips for direct wiring | ||
Service interface | PS/2 socket | ||
Data transfer rate | 1000 Kbit/s 800 Kbit/s 500 Kbit/s 250 Kbit/s 125 kbit/s 50 Kbit/s 20 Kbit/s 10 Kbit/s | ||
| Instructions The supply module XN-BR-24VDC-D must be mounted immediately next to the gateway to provide the supply for the gateway. | |||
| Information about equipment supplied The delivery package for all gateways includes: 2 x end bracket XN-WEW-32/2-SW, 1 x end plate XN-ABPL | |||
| General | |||
Standards | EN 61000-6-2 EN 61000-6-4 EN 61131-2 | ||
Potential isolation | Yes, through optocoupler | ||
Ambient temperature | °C | 0 - +55 | |
Storage | ϑ | °C | -25 - +85 |
Relative humidity | 5 - 95 % (indoor), Level RH-2, no condensation (for storage at 45°C) | ||
Harmful gases | ppm | SO2: 10 (rel. humidity < 75%, no condensation) H2S: 1.0 (rel. humidity < 75 %,no condensation) | |
Vibration | according to IEC/EN 60068-2-6 | ||
Mechanical shock resistance | g | according to IEC 60068-2-27 | |
Continuous shock resistance (IEC/EN 60068-2-29) | According to IEC 60068-2-29 | ||
Drop and topple | According to IEC 60068-2-31, free fall according to IEC 60068-2-32 | ||
Degree of Protection | IP20 | ||
Electromagnetic compatibility (EMC) | |||
ESD | kV | EN 61100-4-2 | |
Electromagnetic fields | V/m | EN 61100-4-2 | |
Burst | EN 61100-4-4 | ||
Surge | EN 61100-4-5 | ||
Radiated RFI | V | EN 61100-4-6 | |
Emitted interference (radiated, high frequency) | dB | EN 55016-2-3 | |
Voltage fluctuations/voltage dips | EN 61131-2 | ||
Type test | to EN 61131-2 | ||
Approvals | CE, cULus | ||
Static heat dissipation, non-current-dependent | Pvs | W | 2.5 |
Other technical data (sheet catalogue) | >Technical Data | ||
| Terminations | |||
Rated data | according to VDE 0611 Part 1/8.92/IEC/EN 60947-7-1 | ||
Connection design in TOP direction | Spring-loaded/screw terminal | ||
Stripping length | mm | 8 | |
Clamping range | max. 0.5 - 2.5 mm2 | ||
Connectable conductors | |||
Solid | mm2 | 0.5 - 2.5 | |
Flexible without ferrule | mm2 | 0.5 - 1.5 | |
Flexible with ferrule | mm2 | 0.5 - 1.5 | |
Flexible with ferrule | mm2 | 0.5 - 1.5 | |
Gauge pin IEC/EN 60947-1 | A1 | ||
| Networking | |||
Bus | CANopen® | ||
Bus protocol | CANopen® | ||
Maximum station configuration | 74 cards (XN) of slice design or max. length of station: 1 m | ||
System supply | Usys | V DC | 24 /5 |
Operational voltage | V DC | 5 (from bus refreshing module) | |
Admissible range | 4.7-5.3 V DC | ||
Residual ripple | % | According to EN 61131-2 | |
Rated current consumption from module bus | IMB | mA | |
Technical data for design verification | |||
Rated operational current for specified heat dissipation | In | A | 0 |
Heat dissipation per pole, current-dependent | Pvid | W | 0 |
Equipment heat dissipation, current-dependent | Pvid | W | 0 |
Static heat dissipation, non-current-dependent | Pvs | W | 2.5 |
Heat dissipation capacity | Pdiss | W | 0 |
Operating ambient temperature min. | °C | 0 | |
Operating ambient temperature max. | °C | 55 | |
Degree of Protection | IP20 | ||
IEC/EN 61439 design verification | |||
10.2 Strength of materials and parts | |||
10.2.2 Corrosion resistance | Meets the product standard's requirements. | ||
10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. | ||
10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. | ||
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects | Meets the product standard's requirements. | ||
10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. | ||
10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.7 Inscriptions | Meets the product standard's requirements. | ||
10.3 Degree of protection of ASSEMBLIES | Meets the product standard's requirements. | ||
10.4 Clearances and creepage distances | Meets the product standard's requirements. | ||
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. | ||
10.8 Connections for external conductors | Is the panel builder's responsibility. | ||
10.9 Insulation properties | |||
10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. | ||
10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. | ||
10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. | ||
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. | ||
10.11 Short-circuit rating | Is the panel builder's responsibility. | ||
10.12 Electromagnetic compatibility | Is the panel builder's responsibility. | ||
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. | ||
Supply voltage AC 50 Hz | V | 0 - 0 | |
Supply voltage AC 60 Hz | V | 0 - 0 | |
Supply voltage DC | V | 18 - 30 | |
Voltage type of supply voltage | DC | ||
Supporting protocol in-bound for TCP/IP | No | ||
Supporting protocol in-bound for PROFIBUS | No | ||
Supporting protocol in-bound for CAN | Yes | ||
Supporting protocol in-bound for INTERBUS | No | ||
Supporting protocol in-bound for ASI | No | ||
Supporting protocol in-bound for EIB/KNX | No | ||
Supporting protocol in-bound for MODBUS | No | ||
Supporting protocol in-bound for Data-highway | No | ||
Supporting protocol in-bound for DeviceNet | No | ||
Supporting protocol in-bound for SUCONET | No | ||
Supporting protocol in-bound for LON | No | ||
Supporting protocol in-bound for SERCOS | No | ||
Supporting protocol in-bound for PROFINET IO | No | ||
Supporting protocol in-bound for PROFINET CBA | No | ||
Supporting protocol in-bound for Foundation Fieldbus | No | ||
Supporting protocol in-bound for EtherNet/IP | No | ||
Supporting protocol in-bound for AS-Interface Safety at Work | No | ||
Supporting protocol in-bound for DeviceNet Safety | No | ||
Supporting protocol in-bound for INTERBUS-Safety | No | ||
Supporting protocol in-bound for PROFIsafe | No | ||
Supporting protocol in-bound for SafetyBUS p | No | ||
Supporting protocol in-bound for other bus systems | No | ||
Supporting protocol out-bound for TCP/IP | No | ||
Supporting protocol out-bound for PROFIBUS | No | ||
Supporting protocol out-bound for CAN | Yes | ||
Supporting protocol out-bound for INTERBUS | No | ||
Supporting protocol out-bound for ASI | No | ||
Supporting protocol out-bound for EIB/KNX | No | ||
Supporting protocol out-bound for MODBUS | No | ||
Supporting protocol out-bound for Data-highway | No | ||
Supporting protocol out-bound for DeviceNet | No | ||
Supporting protocol out-bound for SUCONET | No | ||
Supporting protocol out-bound for LON | No | ||
Supporting protocol out-bound for SERCOS | No | ||
Supporting protocol out-bound for PROFINET IO | No | ||
Supporting protocol out-bound for PROFINET CBA | No | ||
Supporting protocol out-bound for Foundation Fieldbus | No | ||
Supporting protocol out-bound for EtherNet/IP | No | ||
Supporting protocol out-bound for AS-Interface Safety at Work | No | ||
Supporting protocol out-bound for DeviceNet Safety | No | ||
Supporting protocol out-bound for INTERBUS-Safety | No | ||
Supporting protocol out-bound for PROFIsafe | No | ||
Supporting protocol out-bound for SafetyBUS p | No | ||
Supporting protocol out-bound for other bus systems | No | ||
Radiostandard Bluetooth | No | ||
Radiostandard WLAN 802.11 | No | ||
IO link master | No | ||
System accessory | Yes | ||
Degree of protection (IP) | IP20 | ||
With potential separation | Yes | ||
Fieldbus connection over separate bus coupler possible | No | ||
Rail mounting possible | Yes | ||
Wall mounting/direct mounting | No | ||
Front build in possible | No | ||
Rack-assembly possible | No | ||
Suited for safety functions | No | ||
Safety class according to DIN V 19250 | 0 | ||
Category according to EN 954-1 | - | ||
SIL according to IEC 61508 | 0 | ||
SIL according to IEC 62061 | 0 | ||
Performance level acc. to EN ISO 13849-1 | - | ||
Appendant operation agent (Ex ia) | No | ||
Appendant operation agent (Ex ib) | No | ||
Explosion safety category for gas | None | ||
Explosion safety category for dust | None | ||
Width | mm | 50.6 | |
Height | mm | 114.8 | |
Depth | mm | 74.4 |
| Product Standards | UL 508; CSA-C22.2 No. 142; IEC/EN 6113-2; CE marking | ||
| UL File No. | E205091 | ||
| UL Category Control No. | NRAQ, NRAQ7 | ||
| CSA File No. | UL report applies to both US and Canada | ||
| CSA Class No. | 2252-01, 2252-81 | ||
| North America Certification | UL recognized, certified by UL for use in Canada | ||
| Specially designed for North America | No | ||
| Current Limiting Circuit-Breaker | No | ||
| Degree of Protection | IEC: IP20, UL/CSA Type: - |