| Product Name | Eaton DMM Switch-disconnector |
| Catalog Number | 199969 |
| Model Code | DMM-80/1 |
| EAN | 5027590528719 |
| Product Length/Depth | 152 mm |
| Product Height | 108 mm |
| Product Width | 132 mm |
| Product Weight | 0.916 kg |
| Compliances | CE |
| Features | Version as main switch Version as maintenance-/service switch |
| Number of poles | Three-pole |
| Actuator color | Black |
| Actuator type | Toggle |
| Degree of protection | Other |
| Degree of protection (front side) | IP20 |
| Suitable for | Distribution board installation Ground mounting |
| Rated operational power at AC-23A, 400 V, 50 Hz | 30 kW |
| Rated operational power at AC-3, 380/400 V, 50 Hz | 0 kW |
| Rated operational voltage (Ue) at AC - max | 690 V |
| Rated uninterrupted current (Iu) | 80 A |
| Rated conditional short-circuit current (Iq) | 50 kA |
| Rated short-time withstand current (Icw) | 2.5 kA |
| Number of auxiliary contacts (change-over contacts) | 0 |
| Number of auxiliary contacts (normally closed contacts) | 0 |
| Number of auxiliary contacts (normally open contacts) | 0 |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | UV resistance only in connection with protective shield. |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| Feature Name | Feature Value |
|---|---|
| Version as main switch (EF006981) | Yes |
| Version as maintenance-/service switch (EF006986) | Yes |
| Version as safety switch (EF006985) | No |
| Version as emergency stop installation (EF006959) | No |
| Version as reversing switch (EF009408) | No |
| Number of switches (EF005586) | 1 |
| Max. rated operation voltage Ue AC (EF007355) | 690 V |
| Rated operating voltage (EF001435) | 690 V |
| Rated permanent current Iu (EF001389) | 80 A |
| Rated permanent current at AC-23, 400 V (EF011777) | 80 A |
| Rated permanent current at AC-21, 400 V (EF009165) | 80 A |
| Rated operation power at AC-3, 400 V (EF001364) | 0 kW |
| Rated short-time withstand current lcw (EF007050) | 2.5 kA |
| Rated operation power at AC-23, 400 V (EF007027) | 30 kW |
| Switching power at 400 V (EF009166) | 0 kW |
| Conditioned rated short-circuit current Iq (EF001444) | 50 kA |
| Number of poles (EF001391) | 3 |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 |
| Motor drive optional (EF007386) | No |
| Motor drive integrated (EF006697) | No |
| Voltage release optional (EF007491) | No |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| Suitable for front mounting 4-hole (EF007247) | No |
| Suitable for front mounting centre (EF007248) | No |
| Suitable for distribution board installation (EF007262) | Yes |
| Suitable for intermediate mounting (EF007264) | No |
| Colour control element (EF007167) | Black |
| Type of control element (EF006976) | Toggle |
| Interlockable (EF006281) | No |
| Type of electrical connection of main circuit (EF006819) | Screw connection |
| With pre-assembled cabling (EF016444) | No |
| Degree of protection (IP), front side (EF003118) | IP20 |
| Width (EF000008) | 132 mm |
| Height (EF000040) | 108 mm |
| Depth (EF000049) | 152 mm |