View larger
1SDA071351R1
071351
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | e58f8ea5-64f9-48da-8dbb-f7adebb805dd India |
| Simplified SCIP | 7dbd687d-cee2-4486-8cfe-8407ba092fc6 Germany |
| 09232a31-03ec-4a60-b8f1-e60815820511 Sweden | |
| c2926879-6903-4abc-9a8f-936175231ce2 Portugal | |
| 0e8abb12-d8b7-46ed-b1d7-77fc8f8f69e7 Czech Republic | |
| 0b544de2-8f63-4587-80b9-ea307feb8cdd Hungary | |
| ce6e02f9-9552-471f-a111-5964162b1fb5 Poland | |
| 7e71bd4a-9fed-48b7-a57a-f4ebae53cbb0 Netherlands | |
| 46226e19-422a-4654-9658-c1b38ba79fa3 Finland | |
| 059aeffc-1ad0-4672-bd62-32a9a3e249e3 Hungary | |
| 1d1a0c33-7c8a-4dc0-91de-0746c8e30fd6 Spain | |
| d1108b16-7055-441f-ae5e-0bac50f4ec69 Belgium | |
| 1d686f6d-8d3e-43a6-97bb-f8102a813b01 Estonia | |
| e6c31c47-423a-4abd-96e1-e00a7ebce603 Croatia | |
| 8a446412-6054-473c-8a6b-e703667db310 Germany | |
| 5aa5e42b-bea1-4d26-ba18-82b609ce656b Germany | |
| 782c4d8d-4518-44b3-aef2-e14f843f8efb Denmark | |
| 1b001162-0e2d-481b-9125-7f53e6e004da Belgium | |
| ffe42a8e-739c-485b-9c24-c73b961749b9 Norway | |
| 666ca32d-fc03-400b-b452-ddb0170631b1 Poland | |
| 8c86a8a2-d93a-4281-be03-80bba61caeee Germany | |
| f06ce1a8-b9b3-4446-b280-69745ff36f3e France | |
| 23cccfdc-90a6-4e53-af7b-61a3af52a52d Poland | |
| a3a6bd5d-2891-4ce4-b6b8-88242960a953 France | |
| 3b9ab8c5-96d4-4173-a13c-8d8a46b9d7c7 Sweden | |
| 2c83829e-5c2e-4a94-999a-77291b0f1120 Bulgaria | |
| 18bfb485-2a59-428c-b14d-f301af89528c Greece | |
| 8ca4499a-a76f-4d50-aaa2-f9ca4b441b94 Germany | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZANNEEBA000A000000XX |
| EAN | 8015644752019 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 280 mm |
| Product Net Height | 296 mm |
| Product Net Depth / Length | 183 mm |
| Product Net Weight | 16 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 350 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 18 kg |
| Package Level 1 EAN | 8015644752019 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0042 |
| Technical | |
| Connecting Capacity | 400 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 31 W |
| Rated Current (In) | 630 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 50 kA | |
| (660 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 50 kA |
| for 3 s 30 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 66 kA |
| (415 V AC) 66 kA | |
| (440 V AC) 66 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Uninterrupted Current (Iu) | 630 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LI |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 45 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0101 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |