The 1SDA071351R1 ABB E1.2N 630 Ekip Dip LI 4p F F is an air circuit breaker designed for comprehensive electrical distribution protection and fault isolation in heavy commercial and industrial environments. Units of this class interrupt abnormal current surges and safeguard downstream loads from overloads and short circuits.
Exact pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: e58f8ea5-64f9-48da-8dbb-f7adebb805dd India
- Simplified SCIP: 7dbd687d-cee2-4486-8cfe-8407ba092fc6 Germany
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: ZANNEEBA000A000000XX
- EAN: 8015644752019
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | e58f8ea5-64f9-48da-8dbb-f7adebb805dd India |
| Simplified SCIP | 7dbd687d-cee2-4486-8cfe-8407ba092fc6 Germany |
| 09232a31-03ec-4a60-b8f1-e60815820511 Sweden | |
| c2926879-6903-4abc-9a8f-936175231ce2 Portugal | |
| 0e8abb12-d8b7-46ed-b1d7-77fc8f8f69e7 Czech Republic | |
| 0b544de2-8f63-4587-80b9-ea307feb8cdd Hungary | |
| ce6e02f9-9552-471f-a111-5964162b1fb5 Poland | |
| 7e71bd4a-9fed-48b7-a57a-f4ebae53cbb0 Netherlands | |
| 46226e19-422a-4654-9658-c1b38ba79fa3 Finland | |
| 059aeffc-1ad0-4672-bd62-32a9a3e249e3 Hungary | |
| 1d1a0c33-7c8a-4dc0-91de-0746c8e30fd6 Spain | |
| d1108b16-7055-441f-ae5e-0bac50f4ec69 Belgium | |
| 1d686f6d-8d3e-43a6-97bb-f8102a813b01 Estonia | |
| e6c31c47-423a-4abd-96e1-e00a7ebce603 Croatia | |
| 8a446412-6054-473c-8a6b-e703667db310 Germany | |
| 5aa5e42b-bea1-4d26-ba18-82b609ce656b Germany | |
| 782c4d8d-4518-44b3-aef2-e14f843f8efb Denmark | |
| 1b001162-0e2d-481b-9125-7f53e6e004da Belgium | |
| ffe42a8e-739c-485b-9c24-c73b961749b9 Norway | |
| 666ca32d-fc03-400b-b452-ddb0170631b1 Poland | |
| 8c86a8a2-d93a-4281-be03-80bba61caeee Germany | |
| f06ce1a8-b9b3-4446-b280-69745ff36f3e France | |
| 23cccfdc-90a6-4e53-af7b-61a3af52a52d Poland | |
| a3a6bd5d-2891-4ce4-b6b8-88242960a953 France | |
| 3b9ab8c5-96d4-4173-a13c-8d8a46b9d7c7 Sweden | |
| 2c83829e-5c2e-4a94-999a-77291b0f1120 Bulgaria | |
| 18bfb485-2a59-428c-b14d-f301af89528c Greece | |
| 8ca4499a-a76f-4d50-aaa2-f9ca4b441b94 Germany | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZANNEEBA000A000000XX |
| EAN | 8015644752019 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 280 mm |
| Product Net Height | 296 mm |
| Product Net Depth / Length | 183 mm |
| Product Net Weight | 16 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 350 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 18 kg |
| Package Level 1 EAN | 8015644752019 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0042 |
| Technical | |
| Connecting Capacity | 400 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 31 W |
| Rated Current (In) | 630 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 50 kA | |
| (660 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 50 kA |
| for 3 s 30 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 66 kA |
| (415 V AC) 66 kA | |
| (440 V AC) 66 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Uninterrupted Current (Iu) | 630 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LI |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 45 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0101 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |