View larger
1SDA070742R1
070742
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 0c6894c5-4f48-4960-a467-728b71c1266a Italy |
| Simplified SCIP | 94faf7bf-e803-4f2b-9a83-296e79949d48 Croatia |
| 0760c233-0c2c-4ee5-9339-fd2ee644a92c Sweden | |
| a4fc1de8-8577-485c-bea9-2cb2b82a56e7 Poland | |
| d0f0c616-2bef-4660-93a6-e2b6d029c350 Belgium | |
| 6c7a082e-cf8e-4a81-8fc9-8059a9e91d07 Germany | |
| e1bb37f4-eb65-4f10-9d43-101b7ad4d6b1 Germany | |
| 17189d21-6a1d-4af7-a9f1-1ffb573ba4b0 Finland | |
| accb9001-f079-48ee-b1e2-16bd09334807 Poland | |
| cf0e1564-ce77-482a-9b4a-99fef2e0cc84 Portugal | |
| 542e06cb-011b-4454-860d-d704b7beab46 Denmark | |
| acd51c01-9692-4ae5-8dd7-507dca8ca017 Germany | |
| bba271cb-8003-401a-badd-4f7c26f39aa0 Czech Republic | |
| ba94a079-c5aa-4af4-a861-e4ea40a0a414 France | |
| bf991d4a-17d5-4aaa-8d85-37d3770286ee Poland | |
| 691c723e-dc8e-4ab0-b3c1-fdb8308dc423 Belgium | |
| 0aa8174b-1a7d-4d2a-b9ec-57b116abd9b1 France | |
| d0383394-0423-4879-ae2e-34476b7f1661 Germany | |
| 0db28edd-dc92-44be-829c-54e530f67f99 Hungary | |
| 4998f438-9564-42a2-81af-a51d7856c5dc Spain | |
| ac435ac9-92b4-4b7e-a21b-736802eccea1 Sweden | |
| 47c3fdf1-72dc-4829-b757-4e1d93e9eb9b Germany | |
| 1f4547eb-fe22-4dfb-b61a-bbc62276f7dc Netherlands | |
| 7f73b983-36af-4c41-862e-7a34e4893727 Greece | |
| 5ead9c81-249a-4f54-b0a8-27faf7bdc270 Norway | |
| 79a3ec3d-6d47-4734-9b9d-9d53f3a38ddc Estonia | |
| 3a3415e1-b7bd-406d-b87a-ae10a347f0e7 Bulgaria | |
| ef0e5ea5-bb37-46a0-af10-e6c21d4627bc Hungary | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z1BPEFBB000A000000XX |
| EAN | 8015644745929 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Height | 296 mm |
| Product Net Depth / Length | 183 mm |
| Product Net Weight | 15.75 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 16 kg |
| Package Level 1 EAN | 8015644745929 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0001 |
| Technical | |
| Connecting Capacity | 500 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 50 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 42 kA |
| (230 V AC) 42 kA | |
| (380 V AC) 42 kA | |
| (400 V AC) 42 kA | |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 42 kA |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LSI |
| Release Type | EL |
| Short-Circuit Performance Level | B |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 45 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0109 |
| 1SDC200023D0209 | |
| 1SDC200023D0709 | |
| 1SDC200023D0309 | |
| 1SDC200023D0909 | |
| 1SXF200023C2001 | |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0101 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0003 |
| 1SDH000999R0002 | |
| 1SDH000999R0005 | |
| 1SDH000999R0004 | |
| 1SDH000999R0001 | |
| 1SDH000999R0006 | |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |