View larger
1SDA070742R1 ABB E1.2B 800 Ekip Dip LSI 3p F F
1SDA070742R1
070742
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Engineered for advanced power distribution management, this 1SDA070742R1 ABB E1.2B 800 Ekip Dip LSI 3p F F circuit breaker delivers precise protection for electrical infrastructures. Low-voltage air circuit breakers like this are commonly integrated into main switchboards to control high-load distribution circuits and protect critical equipment from fault events.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 0c6894c5-4f48-4960-a467-728b71c1266a Italy
- Simplified SCIP: 94faf7bf-e803-4f2b-9a83-296e79949d48 Croatia
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: Z1BPEFBB000A000000XX
- EAN: 8015644745929
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 0c6894c5-4f48-4960-a467-728b71c1266a Italy |
| Simplified SCIP | 94faf7bf-e803-4f2b-9a83-296e79949d48 Croatia |
| 0760c233-0c2c-4ee5-9339-fd2ee644a92c Sweden | |
| a4fc1de8-8577-485c-bea9-2cb2b82a56e7 Poland | |
| d0f0c616-2bef-4660-93a6-e2b6d029c350 Belgium | |
| 6c7a082e-cf8e-4a81-8fc9-8059a9e91d07 Germany | |
| e1bb37f4-eb65-4f10-9d43-101b7ad4d6b1 Germany | |
| 17189d21-6a1d-4af7-a9f1-1ffb573ba4b0 Finland | |
| accb9001-f079-48ee-b1e2-16bd09334807 Poland | |
| cf0e1564-ce77-482a-9b4a-99fef2e0cc84 Portugal | |
| 542e06cb-011b-4454-860d-d704b7beab46 Denmark | |
| acd51c01-9692-4ae5-8dd7-507dca8ca017 Germany | |
| bba271cb-8003-401a-badd-4f7c26f39aa0 Czech Republic | |
| ba94a079-c5aa-4af4-a861-e4ea40a0a414 France | |
| bf991d4a-17d5-4aaa-8d85-37d3770286ee Poland | |
| 691c723e-dc8e-4ab0-b3c1-fdb8308dc423 Belgium | |
| 0aa8174b-1a7d-4d2a-b9ec-57b116abd9b1 France | |
| d0383394-0423-4879-ae2e-34476b7f1661 Germany | |
| 0db28edd-dc92-44be-829c-54e530f67f99 Hungary | |
| 4998f438-9564-42a2-81af-a51d7856c5dc Spain | |
| ac435ac9-92b4-4b7e-a21b-736802eccea1 Sweden | |
| 47c3fdf1-72dc-4829-b757-4e1d93e9eb9b Germany | |
| 1f4547eb-fe22-4dfb-b61a-bbc62276f7dc Netherlands | |
| 7f73b983-36af-4c41-862e-7a34e4893727 Greece | |
| 5ead9c81-249a-4f54-b0a8-27faf7bdc270 Norway | |
| 79a3ec3d-6d47-4734-9b9d-9d53f3a38ddc Estonia | |
| 3a3415e1-b7bd-406d-b87a-ae10a347f0e7 Bulgaria | |
| ef0e5ea5-bb37-46a0-af10-e6c21d4627bc Hungary | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z1BPEFBB000A000000XX |
| EAN | 8015644745929 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Height | 296 mm |
| Product Net Depth / Length | 183 mm |
| Product Net Weight | 15.75 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 16 kg |
| Package Level 1 EAN | 8015644745929 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0001 |
| Technical | |
| Connecting Capacity | 500 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 50 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 42 kA |
| (230 V AC) 42 kA | |
| (380 V AC) 42 kA | |
| (400 V AC) 42 kA | |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 42 kA |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LSI |
| Release Type | EL |
| Short-Circuit Performance Level | B |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 45 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0109 |
| 1SDC200023D0209 | |
| 1SDC200023D0709 | |
| 1SDC200023D0309 | |
| 1SDC200023D0909 | |
| 1SXF200023C2001 | |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0101 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0003 |
| 1SDH000999R0002 | |
| 1SDH000999R0005 | |
| 1SDH000999R0004 | |
| 1SDH000999R0001 | |
| 1SDH000999R0006 | |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |