Standards
IEC/EN 60947, GB14048
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
Operating range to IEC/EN 60947: -5 - +40 °C
Ambient temperatureOpen
-25 - +55 °C
Ambient temperatureEnclosed
- 25 - 40 °C
Temperature compensation
Continuous
Mechanical shock resistance
10
Sinusoidal
Shock duration 10 ms g
Protection against direct contact when actuated from front (EN 50274)
Finger and back-of-hand proof
Rated impulse withstand voltage [Uimp]
6000 V AC
Overvoltage category/pollution degree
III/3
Rated insulation voltage [Ui]
690 V
Rated operational voltage [Ue]
690 V AC
Safe isolation to EN 61140Between auxiliary contacts and main contacts
440 V AC
Safe isolation to EN 61140Between main circuits
440 V AC
Terminal capacitiesSolid
1 x (1 - 6) mm2
Terminal capacitiesFlexible with ferrule
1 x (1 - 6) mm2
Terminal capacitiesStranded
1 x (1 - 6) mm2
ToolsPozidriv screwdriver
2 Size
Auxiliary and control circuits
Rated impulse withstand voltage [Uimp]
4000 V
Overvoltage category/pollution degree
III/3
Terminal capacitiesSolid
1 x (0.75 - 2.5) mm2
Terminal capacitiesFlexible with ferrule
1 x (0.75 - 2.5) mm2
ToolsPozidriv screwdriver
2 Size
ToolsStandard screwdriver
1 x 6 mm
Rated insulation voltage [Ui]
690 V AC
Rated operational voltage [Ue]
690 V AC
Conventional thermal current [Ith]
10 A
Rated operational current [Ie]AC-15Make contact120 V [Ie]
1.5 A
Rated operational current [Ie]AC-15Make contact220 V 230 V 240 V [Ie]
1.4 A
Rated operational current [Ie]AC-15Make contact380 V 400 V 415 V [Ie]
1.9 A
Rated operational current [Ie]AC-15Make contact500 V [Ie]
0.5 A
Rated operational current [Ie]AC-15Break contact120 V [Ie]
1.5 A
Rated operational current [Ie]AC-15Break contact220 V 230 V 240 V [Ie]
1.5 A
Rated operational current [Ie]AC-15Break contact380 V 400 V 415 V [Ie]
1.9 A
Rated operational current [Ie]AC-15Break contact500 V [Ie]
1.4 A
Rated operational current [Ie]DC L/R ≦ 15 ms
Switch-on and switch-off conditions based on DC-13, time constant as specified.
Rated operational current [Ie]DC L/R ≦ 15 ms24 V [Ie]
0.9 A
Rated operational current [Ie]DC L/R ≦ 15 ms60 V [Ie]
0.75 A
Rated operational current [Ie]DC L/R ≦ 15 ms110 V [Ie]
0.55 A
Rated operational current [Ie]DC L/R ≦ 15 ms220 V [Ie]
0.27 A
Short-circuit rating without weldingmax. fuse
6 A gG/gL
Notes
Ambient air temperature: Operating range to IEC/EN 60947, PTB: -5°C to +55°C
Main circuits terminal capacity solid and flexible conductors with ferrules: When using 2 conductors use equal cross-sections.